All Categories

Testing Instruments

Whiteness and chromaticity tester TP-A10

  • Sample (size) lengthDiameter ≥30 mm, Thickness ≤ 40 mm
  • Measurement modeDiffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
  • Stability≤ 0.1 within 30 min
  • AccuracyChromaticity co-ordinate 0.0001

Whiteness meter TP-A11

  • Sample (size) lengthDiameter ≥30 mm, Thickness ≤ 40 mm
  • SystemD/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
  • Light sourceD65 as illuminating source
  • Zero drift≤ 0.1 %
Tensile Stiffness Tester TP-B10
  • Sample (size) length38×70 mm
  • Measuring range(1-500) mN.m (divided into 7 small ranges)
  • Indication error0.02
  • Test speed(200° ± 20°)/ min
Automatic horizontal tensile tester TP-B11
  • Sample (size) length90 to 200 mm
  • Sample width15 mm, 25 mm, 50mm
  • Measuring range0 to 30, 0 to 100 N,0 to 300 N
  • Accuracy± 1 %

Automatic horizontal tensile tester TP-B12

  • Sample (size) length180 mm (180, 150, 100, 90, 50 mm adjustable)
  • Sample width15 mm
  • Measuring range0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
  • Accuracy± 1 %

Vertical tensile tester TP-B20

  • Sample (size) length0 to 200 mm adjustable
  • Sample width15 mm
  • Measuring range0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
  • Accuracy± 1 %
Pulp beating (refining) freeness tester TP-C10
  • Measurement range0 to 100° SR
  • Sealed testing speed100 ± 10 mm/s
  • Volume of distilled water1000 ± 5 ml
  • Draining time149 ± 1 s
Water absorption tester TP-C20
  • Measurement range0 to 200 mm
  • Specimen size15×250 mm
  • Division value1 mm
  • Number of specimen holders5

Water absorption tester- Cobb Tester TP-C21

  • Metal Cylinder inner area(100 ± 0.2) cm2
  • Metal Cylinder height50 mm
  • Metal roller width(200 ± 0..5) mm
  • Metal roller weight(10 ± 0.5) kg

COBB sample cutter TP-C30

  • Sample diameter125 mm
  • Sample error± 0.2 mm
  • Sample Thickness0.1 to 1.0 mm
  • Dimension240×288×435 mm
Coefficient of friction tester TP-D10
  • Measurement range0.01 to 10 N
  • Slider weight200 g
  • Slider size63×63 mm
  • Testing accuracy± 2 %
Electronic bending stiffness tester TP-E10
  • Testing speed200° ± 20° / min
  • Test range1 to 10000 mN
  • Indicating Error± 1 %
  • Testing length5, 10, 15, 20, 25, 50 mm

Paper and cardboard thickness meter TP-E20

  • Measuring range0 to 4 mm
  • Accuracy0.01 or 0.001 mm
  • GaugeAnalogue gauge display
  • Contact pressure (to create false weight)100 ± 10 kPa

Paper and cardboard thickness meter TP-E21

  • Measuring range0 to 20 mm
  • Accuracy0.01 mm
  • GaugeAnalogue gauge display
  • Contact pressure (to create false weight)20 ± 0.5 kPa
Ink rubber tester TP-F10
  • Sample size (L*B)230×50 mm (can join short samples together)
  • Rub pressure20 ± 0.2 N
  • Friction speed43 times / min
  • Friction area (L*B)155×50 mm
Standard strip cutter TP-G10
  • Sample width15 mm
  • Sample maximum length300 mm
  • Parallelism≤ 0.1 mm
  • Dimension240×520×70 mm

Softness tester TP-H10

  • Measuring range10 to 1000 mN
  • Division value1 mN
  • Accuracy± 1%
  • Indicating Error≤ 0.5

Carton compression tester TP-I10

  • Measuring range0.1 to 10 kN
  • Indication error< ± 1%
  • Platen Size500×500 mm (customized)
  • Operating stroke500 mm (customized)
Carton compression tester TP-I11
  • Measuring range1 to 50 kN
  • Indication error< ± 1%
  • Platen Size800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)
  • Operating stroke800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)
Paper air permeability tester TP-J10
  • Measuring range0 to 1000 ml/min
  • Test area10 ± 0.02 cm2
  • Area differential pressure1 ± 0.01 kPa
  • Inner diameter of grip ring35.68 ± 0.05 mm

Internal Ply bond Tester TP-J11

  • CapacityA: 20 to 500 J/m2 B: 500 to 1000 J/m2
  • Impact angle90°
  • UnitLb-ft/in2  J/m2
  • ErrorA: ± 1 J/m2 B: ± 2 J/m2

Puncture strength tester TP-J12

  • Measuring rangeA (1 to 6) J indicating error ± 0.05 J
    B (1 to 12) J indicating error ± 0.05 J
    C (1 to 24) J indicating error ± 0.05 J
    D (1 to 48) J indicating error ± 0.05 J
    The indicating errors w.r.t measurement range of 20 to 80 %
  • Frictional resistance<0.25 J
  • Pyramid dimensionThree sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm
  • Dimension800×470×840 mm
Paper tearing tester TP-J20
  • Measuring range0 to 1000 mN
  • Resolution0.1 mN
  • Indication error± 1 %
  • Tearing arm104 ± 1 mm
Electronic Tearing tester TP-J21
  • Capacity10 -16000 mN
  • Resolution0.1 mN
  • Tearing arm104 ± 1 mm
  • Tearing angle27.5° ± 5°

Mullen burst tester TP-K10

  • Measurement range0 to 5600 kPa
  • Accuracy± 0.5 % F.S.
  • Compression speed170 ± 15 ml/min
  • Clamp pressure≥ 690 kPa

Mullen burst tester TP-K11

  • Measurement range0 to 1600 kPa
  • Accuracy± 0.5 % F.S.
  • Compression speed95 ± 5 ml/min
  • Clamp pressure≥ 430 kPa
Crush tester TP-L10
  • Measurement range5 to 500 N, 50 to 3000 N
  • Resolution1 N
  • Accuracy± 1 %
  • Variability≤ 1 %
Bekk Smoothness tester TP-L20
  • Measuring scope( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
  • Accuracy±0.1 s within 300 s
  • Vacuum system volume (ml)Bigger volume: 380 ± 1
    Smaller volume: 38 ± 1
  • Contact pressure100 ± 2 kPa

Folding endurance tester TP-M10

  • Measuring scope0 to 99999 s
  • Folding angle135° ± 2°
  • Tensile scope4.9 to 14.7 N
  • Folding head suture size0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm

Aging Oven TAO-A10

  • The maximum temperature300°C
  • Temperature fluctuationWithin ± 0.5°C
  • Temperature uniformityWithin ± 1°C
  • Rotate speed of the turntable11 r/min to 12r/min, turntable dimension diameter: 285 mm

Vacuum Leak Tester TVLT-A10

  • Vacuum degree0 to 90 KPa
  • Accuracy1 % FS
  • Resolution0.1 KPa
  • Vacuum chamber effective size270 × 210 mm
Oxygen Index Tester TOIT-A10
  • Resolution0.1 % O2
  • Measuring range0 to 100 % O2
  • Precision± 0.4 % O2
  • Response time< 10 S
Falling Weight Impact Tester TFWT-A10
  • Temperature range10 to 35°C
  • Maximum falling height2000 mm
  • Resolution of displacement1 mm
  • Height error< ± 2 mm

Charpy/ Izod Impact Tester TCI-A10

  • Impact Speed & Energy (charpy)2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J
  • Impact energy (Izod)3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25J
  • Resolution of impact energy0.001 J
  • Pendulum up angle160°

Heat sealer THS-A10

  • Seal temperatureRoom temperature -250°C
  • Control accuracy± 0.2°C
  • Dwell time0.1 S to 999.9 S
  • Dwell pressure0.05 to 0.7 MPa
Lasting adhesive tester TLAT-A10
  • Standard roller2000 ± 50 g
  • Testing stations3
  • Dimension (L*W*H) tester320×210×550 mm (3 stations)
  • Weight for stations10 kg (3 stations)
Lasting adhesive tester TLAT-A11
  • Standard roller2000 ± 50 g
  • Testing stations6
  • Dimension (L*W*H) tester650×210×550 mm (6 stations)
  • Weight for stations15 kg (6 stations)

Melt flow Indexer TMFI-A10

  • Measuring range0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)
  • Measuring rate0.001 S
  • Temperature range50 to 400°C
  • Temperature precision± 0.5°C

Melt flow Indexer TMFI-A11

  • Measuring range0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)
  • Measuring rate0.001 S
  • Temperature range50 to 400°C
  • Temperature precision± 0.5°C
Primary adhesive tester TPAT-A10
  • Inclined adjustable angle0 to 40°
  • Panel width120 mm
  • Test area width80 mm
  • Standard steel balls1/32 to 1 inch
Vicat softening temperature & HDT machine TVHT-A10
  • Operating temperatureAmbient temperature to 300°C
  • Heating rate50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)
  • Maximum temp. error with heating speed± 5°C under 50°C/ h, ± 1°C under 120°C/ h
  • Range of deformation0 to 10 mm

Rubber Low Temperature Brittleness Tester TRBT-A11

  • Temperature control rangeRoom temperature to -70 ℃ (room temperature ≤ 25 ℃)
  • Temperature accuracy± 0.3 ℃
  • Impact speed0℃ to -30℃ around 2.5 ℃/min
    -30℃ to -40℃ around 2.5 ℃/min
    -40℃ to -70℃ around 2.0 ℃/min
  • Max dimension L × W × H910 × 510 × 860 mm

Three roll mill machine TRMM-A10

  • Mixed capacity0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
  • Temperature rangeRT to 300°C
  • Temperature control systemPID control
  • DisplayLED display
DIN abrasion tester TDAT-A10
  • Test arm weight2.5 N
  • Additional Loads2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
  • Idler150 mm
  • Abrasion stroke40 ± 0.2 M
Mooney viscometer TMV-A10
  • Control temperature rangeNormal temperature to 200°C
  • Temperature display resolution0.01°C
  • Temperature control accuracy± 0.3°
  • Calibration accuracyMooney value ± 0.5

No rotor rheometer TNRR-A10

  • Temperature testerRoom temperature to 200°C
  • Temperature display resolution0.1°C
  • Temperature control accuracy≤ ± 0.3°C
  • Rotor speed100 times/ min

Rubber low temperature brittleness tester TRBT-A10

  • Temperature range-60°C to 0°C
  • Temperature accuracy± 0.5°C
  • Impact speed2 m/s ± 0.2 m/s
  • Temperature fluctuation<± 0.5°C
Rubber-weiss plasticity testing machine TRWM-A10
  • Temperature rangeRT 50° to 300°
  • Temperature accuracy± 1°
  • Measuring range0.01 to 25 mm
  • Accuracy± 0.01 mm

Rockwell hardness meter TRHM-A10

  • Preliminary test force98 N
  • Total test force588, 980, 1471 N
  • Total test force dwell time0 to 30 S
  • Hardness indicationAnalogue display

Rockwell hardness meter TRHM-A11

  • Preliminary test force98 N
  • Total test force588, 980, 1471 N
  • Total test force dwell time1 to 30 S
  • Hardness indicationDigital display
Rockwell hardness meter (motorized type) TRHM-B10
  • Preliminary test force98 N
  • Total test force588, 980, 1471 N
  • Brinell hardness test306, 613, 1839 N
  • Vickers hardness test294, 588, 980 N
Digital low load Vickers Hardness tester TDVH-A10
  • Test force9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
  • Hardness value symbolHV1, HV5, HV10, HV20, HV30, HV250
  • Error range in display± 3.0 %, ± 2.0 %
  • Hardness indicationDigital display

Digital Brinell hardness Tester TDBH-A10

  • Test force612.5 N, 980 N, 1225 N
  • Brinell hardness test1837.5 N, 2450 N, 4900 N/7350 N, 9800 N, 14700 N/29400 N
  • Hardness measuring area8 to 650 HBW (hard metals steel ball)
  • Hardness indicationDigital display

Portable Vibration Calibrator LPVC-A10

  • Frequency (continually adjustable)10 Hz to1280 Hz + 0.01 %
  • Amplitude acceleration ( at 30m/s2 pk )40 Hz to 320 Hz + 0.3 dB + 1 digit
  • Amplitude velocity ( at 25mm / sec pk )40 Hz to 320 Hz + 0.5dB +1 digit
  • Amplitude displacement ( at 50 μm pk-pk )40 Hz to 320 Hz + 0.5 dB + 1 digit

Benchtop gloss meter TBGM-A10

  • Test angle60°
  • Gloss aperture2 × 3 mm
  • Measurement range0 to 1000 GU
  • Repeatability0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)

Soil nutrient tester TSNA-A10

  • Measuring range0.001 to 9999
  • StabilityA (absorbency of light) <0.003 within 3 mins
  • Linearity error<3.0 %
  • Repeatability errorA (absorbency of light) <0.005

Soil nutrient tester TSNA-A11

  • Measuring range0.001 to 9999
  • StabilityA (absorbency of light) <0.003 within 3 mins
  • Linearity error<3.0 %
  • Repeatability errorA (absorbency of light) <0.005
Soil Salinity tester TSST-A10
  • Salinity Measurement range0.00 to 19.99 ms/cm
  • Measuring accuracyEC ± 2% full scale
  • Temperature Measurement range-5 to 50°C
  • Temperature accuracy± 0.5°C
Soil Water potential tester TSWT-A10
  • Measuring range0 to 100 kPa
  • Resolution0.01 kPa
  • Accuracy± 1 kPa
  • Soil temperature measuring range-55 to 105°C

Soil water hardness meter TSHM-A10

  • Maximum load100 kg ( kg and N can be switched automatically)
  • Resolution0.01 g
  • Accuracy± 0.5 %
  • Measuring depth0 to 40 mm

Soil water hardness meter TSHM-A11

  • Maximum load100 kg ( kg and N can be switched automatically)
  • Resolution0.01 g
  • Accuracy± 0.5 %
  • Measuring depth0 to 450 mm
Soil moisture meter TSMM-A10
  • Measurement range0 to 80 %
  • Resolution0.1
  • Accuracy± 2 % n (non-saturation condition)
  • Needle280 mm
Soil moisture meter TSMM-A11
  • Measurement range0 to 90 %
  • Resolution0.1 or 0.01
  • Accuracy± 5 % n (non-saturation condition)
  • Needle235 mm

Soil moisture meter TSMM-A12

  • Measurement range0 to 60 %
  • Resolution0.1
  • Accuracy± 5 % n (non-saturation condition)
  • Needle280 mm