Spectrometer

FTIR Spectrometer LIR-B10

  • Spectral Range7800 cm-1 to 350 cm-1
  • Resolution0.85 cm-1
  • Wave number precision± 0.01 cm-1
  • Scanning speedMicroprocessor control, different scanning speed selectable

Atomic Fluorescence Spectrometer LAFS-A10

  • Beam ConfigurationDual Channel
  • Elements ( Measuring Range ){"As, Se, Pb, Bi, Sb, Te, Sn":"< 0.01 \u00b5g\/L","Hg, Cd":"< 0.001 \u00b5g\/L","Zn":"< 1.0 \u00b5g\/L","Ge":"< 0.1 \u00b5g\/L"}
  • Precision ( RSD )< 1.0
  • Linear rangeMore than 3 orders of magnitude

ICP spectrometer LICP-A10

  • Wavelength range ( 3600 lines / mm )180 to 500 nm
  • Wavelength range ( 2400 lines / mm )180 to 800 nm
  • Temperature20 ~ 28 °C
  • Elements per minute26 elements

ICP Spectrometer LICP-B10

  • Monochromator Specifications{"Optical type":"Czerny turner","Resolution":"\u2264 0.015nm (3600 line grating) \u2264 0.030nm (2400 line grating)","Focal length":"1000 mm","Grating specifications":"huge holographic grating with 3600 L\/mil or 2400 L\/mil and 80 mm \u00d7 100 mm of ruling area","Wavelength range":"195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating"}
  • Solid State Power Specifications{"Frequency":"27.12 MHz Frequency stability: < 0.05%","Spray chamber":"Scott double pass spray chamber","Output power":"800 W to 1600 W, adjustable with power efficiency more than 65%","Output power stability":"\u2264 0.05%","Induction coil":"25 mm \u00d7 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)"}
  • Technical Specifications{"Suitable sample content range":"Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%","Repeatability":"short-term stability- RSD \u2264 1.5% Long-term stability: RSD \u2264 2%","Test speed":"5 to 8 elements \/ min","Limits of detection (LOD, \u00b5g\/L) for most elements":"1ppb to 10ppb"}
  • Control Circuit{"Photomultiplier tube specification":"R212 \/ R928","Negative high voltage":"-50 to -1000 V","Circuit measuring range":"(10-12<\/sup> to 10 -4<\/sup>) A","Signal acquisition":"VF conversion"}
ICP Spectrometer LICP-A11
  • Wavelength range180 to 900 nm
  • Elements per minute15 elements
  • Temperature29 °C
  • Incident slit25 µm
ICP Spectrometer LICP-A12
  • Wavelength range195 to 800 mm
  • Elements per minute10 elements
  • Temperature range32 °C
  • Incident slit20 µm

XRF-Spectrometer LXRF-A10

  • Measureable elementsS to U
  • Detection limit1 ppm
  • Temperature15 ~ 30 °C
  • Elemental content1 ppm to 99 %

Handheld XRF Spectrometer LXRF-B10

  • Analytical MethodEnergy dispersive X-ray fluorescence analytical Method
  • Elements MeasuringAtomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • RangeSimultaneous detector
  • Content measurement rangeppm to 100%
Handheld XRF Spectrometer LXRF-B11
  • Analytical MethodEnergy dispersive X-ray fluorescence analytical Method
  • Elements MeasuringAtomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
  • RangeSimultaneous detector
  • Content measurement rangeppm to 99.99%

XRD Diffractometer LXRD-A10

  • X-ray TubleGlass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kW
  • Focus Size1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm
  • Stability≤ 0.01 %
  • Tube Current5 to 80 mA

Angular Spectrometer LASM-A10

  • Angle Measurement Accuracy1inch
  • Optical Parameter{"Focal Length":"170 mm","Effective Aperture":"\u03a6 22 mm","Field of View":"3\u00b0 22inch","Focal Length of Telescope\u2019s Eyepiece":"24.3 mm","Maximum Length Between Collimator and Telescope":"120 mm","Slit Width":"0.02 to 2 mm","Diopter Compensation Range":"\u2265 \u00b1 5 diopters"}
  • Divided Circle{"Diameter":"\u03a6178 mm","Circle Graduation":"0\u00b0 to 360\u00b0","Division":"0.5\u00b0","Vernier Reading Value":"1inch"}
  • Stage{"Diameter":"\u03a670 mm","Rotating Range":"360\u00b0","Range of Vertical Adjustment":"20 mm"}