All Categories

Environmental Monitoring Equipments

Handheld C2H4 Ethylene Gas Detector LEGD-A10

  • SamplingWith internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection
  • GasEthylene C2H4
  • Measure Range0 to 1000 ppm
  • Resolution1ppm

Portable 2 in 1 gas detector LPTG-A10

  • Sampling methodDiffusion
  • Sensor typeCO2: solid electrolyte sensor, O2:electrochemical sensor
  • Detection rangeCO2:0.04 to 5.00 % and O2:0.0 to 30.0 %
  • Detection accuracyCO2:± 30 % rdg (rdg = reading) and O2:± 3 % F.S. (F.S. = full scale)
Portable Multiple Gas Detector LPMG-A10
  • Sampling MethodDiffusion
  • Working conditions
    Temperature -20 to 50°C
    Pressure 0.9 to 1.1 (standard atmospheric pressure)
    Humidity 10 to 95 % RH (no dew condensation)
  • Explosion proof gradeExia II CT3
  • Protection gradeIP65
Portable infrared gas detector LIGD-A10
  • Measurement principleNon-dispersive infrared  (NDIR)
  • Gas DetectedSF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.)
  • Detection Uncertainty<1.5 % F.S
  • Detection Resolution0.1ppm

Portable NO<sub>2</sub> Gas Detector LPSG-A21

  • Gas detectedNO2
  • Detection principleElectrochemistry
  • Sampling methodPumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
  • Measure range0 to1000 ppm

Portable SO<sub>2</sub>Gas Detector LPSG-A20

  • Gas detectedSulfur dioxide SO2
  • Detection principleElectrochemistry
  • Sampling methodPumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
  • Measure range0 to1000 ppm
Portable Single Gas Detector LPSG-A10
  • Sampling methodDiffusion
  • Measurement principleElectrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas)
  • Detector gasFlammable gases, oxygen gas, toxic and harmful gases
  • Response time
    CO2 < 10 s
    O2, flammable gases < 20 s
    CO, H2S, SO2, NO, ClO2, NO2, H2 < 30 s
    HCN, NH3, PH3 < 100 s
Portable 10 in 1 Multi Gas Detector LMGD-A10
  • Gas DetectedO2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3
  • Detection principleElectrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC)
  • Measurement RangeO2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPM
  • ResolutionO2: 0.01% VOL, CH4: 1 PPM, CO2:1 PPM VOC:1 PPM, CO:0.1 PPM, H2S: 0.1 PPM SO2: 0.01 PPM, CL2: 0.01 PPM, NO2: 0.01 PPM, NH3:0.01 PPM

Portable Nitrogen N2 Gas Detector LNGD-A10

  • Gas DetectedNitrogen N2
  • Detection principleElectrochemical principles
  • Measurement Range0 to 100 %.Vol
  • Resolution0.01 %VOL

Digital Differential Pressure Meter LDPM-A10

  • Measuring range0 ∼ 125 Pa
  • Accuracy0 ± 0.2 Pa (liner error)
    ± 1 %
  • Operating temperature range0 °C ∼ 50 °C
  • Operational humidity˂ 85 RH

Digital Differential Pressure Meter LDPM-A20

  • Measuring range± 500 Pa
  • Repeatability± 0.2 % FS
  • Resolution0.1 Pa
  • Sampling rate0.5 s

Handheld Ozone Tester LHOT-A10

  • Measurement range0 ppm ∼ 5 ppm
  • Resolution0.001 ppm ( 0 ppm ∼ 5 ppm )
  • Temperature range˗ 40 °C ∼ 120 °C
  • Humidity range0 % ∼ 100 % RH

Online Ozone Meter LOOM-A10

  • Ozone measurement range0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional )
  • Flow rate1.5 L/min
  • Accuracy0.01 ppm or 3 % of reading
  • Resolution0.001 ppm

UV Absorption Ozone Meter LUOM-A10

  • Ozone measurement range0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm
  • Flow rate1 L/min
  • Accuracy0.01 ppm
  • Measuring time10 seconds

6 in 1 Multifunctional Environmental Meter LMEM-A10

  • Temperature Measurement Range-10℃ to 60℃
  • Temperature Resolution0.1°C
  • Temperature Accuracy± 1.5℃
  • Relative Humidity Range20% to 80% RH

Floor Balance LFRB-A20

  • Capacity50 kg
  • Accuracy1 g
  • Speed1 s
  • Value stable time2 s