Automatic Bomb Calorimeter LABC-A10

  • Calorimeter typeIsoperibol
  • Temperature range5 to 40°C
  • Measurement range5 to 40 MJ/ kg
  • Operation ModeThe outer barrel temperature is constant

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter typeIsoperibol
  • Temperature range5 to 40°C
  • Measurement range5 to 40 MJ/ kg
  • Operation ModeA. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode
Automatic Bomb Calorimeter LABC-B10
  • Calorimeter typeIsoperibol
  • Oxygen fillingFully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume250 ml
  • Analysis time< 8 min full test process: <10 min
Automatic Bomb Calorimeter LABC-B11
  • Calorimeter typeIsoperibol
  • Oxygen fillingSemi-automatic
  • Bomb volume282 ml
  • Analysis time15 to 25 min

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor VehiclesNational standard: 65.0 to 110.0/RON
    National-V standard: 70 to 115.0/RON
    Blended gasoline: 75.0 to 120.0/RON
    Light gasoline: 50.0 to 85.0 /MON
    Isomerized gasoline: 85.0 to 120.0/RON
    Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For EthanolE93: 92.0 to 95.0/RON
    E97: 95.0 to 99.0/RON
    Judgement: 60.0 to 120.0/RON
  • Measuring Range For Automobile Diesel FuelsCetane number: 25 to 75/CN
    Cetane index: 20 to 80/CI

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement itemmotor gasoline and diesel
  • measurement unit of octane is ON40 to 120
  • Permissible error of octane± 0.5 max
  • Fluctuate range of octane± 0.2 max

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask100 ml,50 ml
  • Conical flask100ml
  • Separatory funnel250ml
  • Ambient temperature(-10 )°C to 35 °C

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature≤ 35 °C
  • Relative humidity≤ 85 %
  • Precision of titration tubeScale division is 0.02 ml
  • Total power consumption≤ 1200 W
Acid Number Tester LAAT-A12
  • Measurement range≥0.05 mg KOH/g
  • Potential measurement range0 to 1800.0 mV
  • Burette volume10 mL
  • Minimum titration volume0.001 ml
Base Number Tester LAAT-A13
  • Volumetric analysisTitration condensation: 0.1 N;
    Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titrationTitration condensation: 0.1 N;
    Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential controlTitration condensation: 0.1 N;
    Controlling accuracy: ≤ 10 mV
  • Ambient temperature0 ~ 35 ℃

Aniline Point Tester LAPT-A10

  • Measurement rangeRoom temperature ~ 150°C
  • Stirring speed0 ~ 1200 r / min
  • Heating power25 W
  • Interior Dimension360 × 250 × 545 mm

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy≤ 0.5 ℃
  • Temperature controlling rangeRoom temperature ~ 200 ℃
  • Power supply for illumination5 V
  • Power of motor2 kW

PMCC Flash Point Tester LCFP-A10

  • Ambient temperature≤ 35 °C
  • Relative humidity≤ 85 %
  • Temperature range5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
  • Aperture of ignition device0.8 mm

Automatic PMCC Flash Point Tester LCFP-A11

  • Ambient temperature10 °C ~ 40 °C
  • Relative humidity≤ 80 %
  • Measurement RangeAmbient Temperature ~ 250 °C
  • Flash PointLower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C
Automatic PMCC Flash Point Tester LCFP-A13
  • Ambient temperature10 °C ~ 40 ℃
  • Relative humidity≤ 80 %
  • Ignition Modeelectron igniter / gas flame
  • Temperature rangeRoom Temperature ~ 300 ℃

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10

  • Ambient temperatureRoom temperature to 35 °C
  • Relative humidity≤ 85 %
  • Timing range1 s to 9 min 59 s
  • Temperature controlling rangeRoom temperature to 99.9 °C

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11

  • Ambient temperatureRoom temperature to 35 °C
  • Relative humidity≤ 85 %
  • Temperature controlling rangeRoom temperature to 99.9 °C
  • Temperature controlling accuracy± 1 °C

Density Tester LDMT-A10

  • Cubage of bathФ300 × 380 mm
  • Temperature controlling range0 °C ~ 100 °C
  • Temperature controlling accuracy± 0.2 °C
  • Temperature sensorIndustrial platinum resistance, Pt100

Automatic Distillation Apparatus LADA-A10

  • Heating power2 kW
  • Cooling power0.5 kW
  • Steam temperature0 to 400℃
  • Oven temperature0 to 500℃

Benzene Distillation Tester (Low Temperature) LDT-A11

  • Ambient temperature-10°C to 35°C
  • Relative humidity≤ 85 %
  • ThermometerEach one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
  • Scale division0.1 ℃
Distillation Tester Dual Units LDT-A15
  • Graduated flasks100 ml
  • Scale division of graduated flask1ml
  • Distillation flask125 ml
  • Ambient temperature≤ 35 °C
Distillation Tester (low temperature Double units) LDT-A16
  • Graduated flasks100 ml
  • Distillation flask125 ml
  • Ambient temperature≤ 35 °C
  • Relative humidity≤ 85 %

Distillation Tester Front Type LDT-A14

  • Distillation flask125 mL
  • Ambient temperatureRoom temperature to 35 °C
  • Relative humidity≤ 85 %
  • Thermometer(-2 )°C to 300 ℃ and (-2) °C to 400 ℃

Distillation Tester LDT-A10

  • Graduated flasks10 ml and 100 ml
  • Scale division of graduated flask10 ml is 0.1 ml and 100 ml is 1 ml
  • Ambient temperature(-10) °C ~ 35 °C
  • Relative humidity≤ 85 %
Distillation Tester LDT-A12
  • Graduated flasks100 ml
  • Scale division of graduated flask1 ml
  • Outer diameter of distillation flaskφ65
  • Refrigeration tubeφ14
Distillation Tester (low temperature single unit) LDT-A17
  • Graduated flasks100 ml
  • Distillation flask125 mL
  • Ambient temperature≤ 30 °C
  • Relative humidity≤ 85 %

Vacuum Distillation Tester LDT-A13

  • Ambient temperature5 °C to 35 ℃
  • Relative humidity≤ 85 %
  • Cubage of buffer vessel1000 ml
  • Max. Residual pressure≤ 2 mm Hg

Dropping Point Tester (Oil Bath) LDPT-A10

  • Beaker quantity600 ml
  • Ambient temperature(-10) °C ~ 40 °C
  • Relative humidity≤ 85 %
  • Thermometer Measurement range(-5) °C ~ 300 °C

Dropping Point Tester (Air bath) LDPT-A11

  • Ambient temperature≤ 35 ℃
  • Relative humidity≤ 85 %
  • Heating power of electric furnace250 W × 2
  • Total power consumption≤ 700 W

Engler Viscometer LEV-A10

  • Graduated Flask200 ± 0.2 ml
  • Standard Water Value51 ± 1 s
  • Temperature Range0 ~ 100 °C
  • Temperature Controlling Accuracy± 0.2 °C

Engler Viscometer LEV-A11

  • Graduated Flask100 ml
  • Standard Water Value51 ± 1 s
  • Temperature Range0 ~ 100 °C
  • Temperature Controlling Accuracy± 0.1 °C
Engler Viscometer LEV-B10
  • Graduated Flask200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
  • Standard Water Value51 ± 1 s
  • Temperature Range0 ~ 100 °C
  • Ambient Temperature10 °C ~ 40 °C

Existent Gum Tester LEGT- B30

  • Bath typeOil bath
  • Bath capacity5000 ml ± 50 ml
  • Ambient temperatureRoom temperature to 35 °C
  • Relative humidity≤ 85 %

Existent Gum Tester LEGT- B31

  • Evaporation bath type and sizeAluminum block bath, φ260 × 130 mm
  • Holes for testing3 pieces
  • Size of holes for testing cylinderφ51 × 70 mm
  • Flow rate displayFlow meter
Existent Gum Tester LEGT- B32
  • Evaporation bath type and sizeAluminum bath φ260 × 130 mm
  • Holes for testing5 pieces
  • Size of holes for testing cylinderφ51 × 70 mm
  • Working temperature160 ℃ ~ 165℃

Kinematics Viscometer LKV-A11

  • Ambient temperature(-10) °C ~ 35 °C
  • Relative humidity≤ 85 %
  • Capillary viscometer11 pieces
  • Stirring motor6 W, 1200 rpm

Kinematics Viscometer LKV-A12

  • Ambient temperature(-10) °C ~ 35 °C
  • Relative humidity≤ 85 %
  • Capillary viscometer11 pieces
  • Stirring motor6 W, 1200 rpm
Kinematics Viscometer LKV-A13
  • Ambient temperature(-10) °C ~ 35 °C
  • Relative humidity≤ 85 %
  • Capillary viscometer7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
  • Stirring motor6 W, 1200 rpm
Low Temperature Kinematic Viscosity Tester LKV-A14
  • Ambient temperature≤ 30 °C
  • Relative humidity≤ 85 %
  • Capillary viscometer13 pieces
  • Stirring motor6 W, 1200 rpm

Kinematics Viscometer LKV-A15

  • Ambient temperature(-10) °C ~ 35 °C
  • Relative humidity≤ 85 %
  • Capillary viscometer11 pieces
  • Stirring motor6 W, 1200 rpm

Kinematics Viscometer LKV-A16

  • Ambient temperature0 ~ 40 ºC
  • Relative humidity20 ~ 90 %, RH while 40 ℃
  • Temperature controlling accuracy± 0.1 °C
  • Timing range0.0 s ~ 9999.9 s
Kinematics Viscometer LKV-A10
  • Ambient temperature15 to 35°C
  • Relative humidity≤ 85%
  • Capillary viscometer6 capillary Pinkevitch viscometer tubes
  • Stirring motor1200 rpm

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

  • Ambient temperature(-10)℃ ~ 35 ℃
  • Relative humidity≤ 85 %
  • Sample cup Inner diameter31.0 ~ 32.0 mm
  • Sample cup Wall thickness1.0 ~ 1.5 mm

Solidifying Point Tester LLTT-A13

  • Temperature controlling accuracy± 0.5 ℃
  • Refrigeration systemNew-type refrigeration compressor
  • Cold troughTwo holes in one trough, and same temperature
  • Ambient temperature≤ 30 ℃
Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15
  • Refrigeration systemNew-type refrigeration compressor
  • Controlling temperature of cold troughCold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
  • Ambient temperature≤ 30 ℃
  • Relative humidity≤ 85 %
Multifunctional Low Temperature Tester LLTT-A16
  • Refrigeration systemNew-type refrigeration compressor
  • Controlling temperature of cold troughCold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C
  • Ambient temperature≤ 30 ℃
  • Relative humidity≤ 85 %

Solidifying Point Tester LLTT-A20

  • Temperature controlling accuracy± 0.5 °C
  • Refrigeration systemNew-type refrigeration compressor
  • Cold troughOne trough with two baths, temperatures in two baths are equal
  • Controlling temperature of cold troughRoom temperature ~ (-70) °C

Solidifying Point Tester (Solidifying Point and Cold Filter Plugging Point) LLTT-A21

  • Refrigeration systemNew-type refrigeration compressor
  • Cold troughOne trough with two baths, temperatures in two baths are equal
  • Controlling temperature of cold troughRoom temperature ~ (-70) °C
  • Ambient temperature≤ 30 ℃
Solidifying Point Tester ('-20°C +80°C') LLTT-A22
  • Temperature controlling accuracy± 0.5 °C
  • Refrigeration systemNew-type refrigeration compressor
  • Cold troughOne trough with two baths, temperatures in two baths are equal
  • Controlling temperature of cold troughRoom temperature ~ (-70) °C
Automatic Pour Point Tester LLTT-A23
  • Ambient temperature≤ 30 ℃
  • Refrigeration speed> 40 °C / 10 min
  • Repeatability for solidifying point≤ 2 °C
  • Repeatability for pour point≤ 3 °C

Solidifying Point Constant Temperature Water Bath LLTT-A10

  • Capacity20 L
  • Temperature rangeAmbient +5°C to 100°C
  • Precision± 0.1℃
  • Stirring range1200 r/min

Freezing Point Tester LLTT-A11

  • Freezing point range-54°C to 2°C
  • Cold bath measurement temperature range-70° to 20°C
  • Temperature controlling accuracy±0.5°C
  • Bath liquids stirringElectric
Pour and Cloud Point Tester LLTT-A14
  • Chamber quantity2 chambers
  • Chamber 01 temperature controlAmbient to -51 ℃
  • Chamber 02 temperature controlAmbient to -65 ℃
  • Temperature precision±1°C

Open Cup Flash Point Tester LOFP-A10

  • Thermometer0 ℃ ~ 360 °C
  • Scale Division1 °C
  • Ambient Temperature≤ 35 °C
  • Relative Humidity≤ 85 %

Cleveland Open Cup Flash Point Tester LOFP-A11

  • Thermometer6 ℃ ~ 400 ℃
  • Scale Division2 °C
  • Spout Aperture0.6 ~ 0.8 mm
  • Ambient Temperature-10 ℃ ~ 50 ℃
Automatic COC Flash & Fire Point Tester LOFP-B10
  • Ambient Temperature10 ℃ ~ 40 ℃
  • Relative Humidity≤ 85 %
  • Temperature Measurement- Full ScaleAmbient temperature to ~ 400 ℃
  • Temperature Measurement- Repeatability≤ 4 ℃
Automatic Cleveland Open Cup Flash Point Tester LOFP-A12
  • Ambient Temperature10 ℃ ~ 40 °C
  • Relative Humidity≤ 80 %
  • Temperature Measurement- Full ScaleAmbient temperature to 300 °C
  • Temperature Measurement- Repeatability≤ 8 °C

Mechanical Impurity Tester (Weight Method) LMIT-A21

  • Dimension390 x 260 x 590 mm
  • Total power consumption≤ 1200 W
  • Power supplyAC 220 V ± 10 %, 50 Hz
  • Heating power of water bath1000 W

Wax Oil Content Tester LWCT-A22

  • Power supplyAC 220 V ± 10 %, 50 Hz
  • Temperature controlling range in water bathRT ~ 90 ℃ ± 5 ℃
  • Cooling bath temperature(-35) ℃ ± 1 ℃
  • Evaporation temperature35 ℃ ± 1 ℃
Insulating Oil Breakdown Voltage Tester LIBT-A23
  • Power supplyAC 220 V ± 5 % , 50Hz
  • Measurement range0 ~ 75 kV
  • Voltage rising rate3 kV ± 10 % / s
  • Distance between electrodes2.5 mm
Color Tester LCT-A20
  • Light source220 V, 100 W
  • Temperature of grinding milk white light bulb2750 ± 50 K
  • Light hole( Φ14)26 pieces
  • Color comparing tubeΦ32 mm

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

  • Samples2
  • Oil bath cubage30 L
  • Angle between bomb and water surface30 °
  • Speed of rotary assembly100 ± 5 RPM

Transformer Oil Oxidation Stability Tester LOST-D11

  • Samples6
  • Temperature controlling modeAutomatic digital temperature
  • Temperature controlling rangeRoom temperature ~ 160 °C
  • Temperature controlling accuracy± 0.2 °C
Distillate Fuel Oil Oxidation Stability Tester LOST-D12
  • Samples8
  • Temperature100 ℃
  • Temperature controlling accuracy0.1 ℃
  • Flow meter3 ± 0.3 L / H oxygen
Oxidation Stability Tester (Lubricating Grease) LOST-D20
  • Temperature RangeAmbient to 150℃
  • Temperature Precision± 0.1°C
  • Test Unit2 units
  • Heating Power1800 W

Gasoline Oxidation Stability Tester LOST-D13

  • TypeCompact; Desktop
  • DesignIntegrated
  • BathMetal bath (without water usage)
  • Temperature control point of metal bath100℃ ± 1℃

Oxygen Bomb Calorimeter LBC-C21

  • Temperature controlling range10 ℃ ~ 35 ℃
  • Temperature resolution0.001 ℃
  • Mean value of heat capacity15 kJ / K
  • Ambient temperature20 ℃ ± 5 ℃

Oxygen Bomb Calorimeter LBC-C22

  • Temperature measurement range10 ~ 35 ℃
  • Repeatability error≤ 0.2 % (Grade C)
  • Endured pressure in oxygen bomb20 MPa
  • Operation environment temperature15 ~ 28 ℃
Oxygen Bomb Calorimeter LBC-C20
  • Heat capacity14000 ~ 15000 J / K
  • Temperature measurement range10 ~ 35 ℃
  • Repeatability error≤ 0.2 % (Grade C)
  • Endured pressure in oxygen bomb20 MPa

Carbon Residue Tester (CONRADSON METHODS) LRCT-B10

  • Porcelain crucible30 ml
  • Inner iron crucible75 ml
  • Outer iron crucible190 ml
  • BurnerMig Burner

Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11

  • Bath typeFour holes with a furnace
  • Heating typeElectric resistance furnace
  • Temperature controlling range0 ~ 520 °C
  • Temperature controlling accuracy± 5 °C
Carbon Residue Tester (Ramsbottom) LRCT-B20
  • Coking furnaceMetal furnace
  • Heating modeElectric heating
  • Test unit5 units
  • Temperature rangeAmbient to 550°C

Rotational Viscometer LRV-A10

  • Viscosity measurement range10 ~ 2000000 MPa•s
  • Ambient temperature5 °C ~ 35 °C
  • Ambient humidityNot more than 80 %
  • SpindlesFour spindles of No.1 ~ 4

Copper Strip Corrosion Tester LRCT-A13

  • Sample hole4 pieces
  • Sample quantity4 to 12 pieces
  • Ambient temperatureRoom temperature to 35 °C
  • Temperature controlling rangeRoom temperature to 100°C

Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10

  • Sample hole2 pieces
  • Speed of stirring motor1400 rpm
  • Ambient temperature10 to 35°C
  • Temperature controlling rangeRoom Temperature to 100°C
Lubricating Oil Rust Characteristics Tester LRCT-A11
  • Sample hole4 pieces
  • Speed of stirring motor1400 rpm
  • Speed for sample stirring1000 ± 50 rpm
  • Ambient temperatureRoom temperature to 35°C
Rust Characteristics and Corrosion Tester LRCT-A12
  • Sample hole4 pieces
  • Ambient temperatureRoom temperature to 35°C
  • Temperature controlling range0 to 100°C
  • Temperature controlling accuracy± 1°C

X-ray Fluorescence Sulfur in Oil Analyzer LST-A10

  • Sample quantity2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
  • Measurement time60, 120, 240, 300, and 600 s at random
  • Measurement range7 ppm to 5 %
  • Repeatability< 0.029 (S + 0.6)

Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11

  • Air flow rateNot less than 150 L / h
  • Max. Preset time99 min 59 s (100 min)
  • Chamber diameter of ovenΦ22 mm
  • Heating power of oven1400 W × 2

Vapor Pressure Tester (REID METHOD) LVPT-C10

  • Operation temperature of water bathRT ~ 90 °C
  • Temperature controlling accuracy± 0.1 °C
  • Dimensions550 × 520 × 102 mm
  • Pressure meter accuracy± 0.4 % kPa

Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11

  • Test bombTwo samples or a group of parallel samples
  • Bath temperature37.8 °C
  • Temperature controlling accuracy0.1 °C
  • Dimensions500 × 560 × 680 mm, 950 × 540 × 720 mm

Coulometric Karl Fischer Titrator LWT-A30

  • Ambient Temperature10°C to 35°C
  • Measurement Range0 to 100 mg
  • Resolution0.1 µg
  • Max. Electrolysis Speed40 µg /s

Water Content Tester LWT-A10

  • Ambient Temperature Range≤ 35°C
  • Relative Humidity≤ 85%
  • Heating Mantle Cap Power1000 W
  • Sample Determination1 at a time
Water Content Tester LWT-A11
  • Ambient Temperature Range≤ 35°C
  • Relative Humidity≤ 85%
  • Heating Mantle Cap Power1000 W × 2
  • Sample Determination2 at a time
Crude Petroleum Water Content Tester LWT-B10
  • Ambient Temperature Range-10 to 35°C
  • Relative Humidity≤85%
  • Distillation Flask1000 ml
  • Receiver5 ml, with 0.05 ml graduation

Coulometric Karl Fischer Titrator LWT-A31

  • Maximum current400 mA
  • Measurement range3 µg to 9999.9 µg
  • Resolution0.1 µg
  • Precision 1± 2 µg (3µg H2O to 20µg H2O)

Automatic Tag Closed Flash Point Tester LACF-A10

  • Experimental temperature range-50 to 70°C
  • Test sample volume50 ml
  • Ambient temperature range10 to 40°C
  • Humidity≤ 85%

Specific Gravity Tester LSGT-A10

  • Vessel Volume 4000 ml × 2
  • Power of Vacuum pump160 W
  • Negative power3.7 kPa(27.75 mmHg)
  • Power of shaking machine30 W

Automatic Dielectric Tester LADT-A10

  • Capacity2.0 kVA
  • Speed of voltage increase2 k V/ s
  • Voltage inspection accuracy0.01
  • Breakdown sensitivity< 0.1 kV

Automatic Softening Point Tester LSPT-A10

  • Measurement range32 ℃ to 160 ℃
  • Ambient temperature35 °C
  • Temperature resolution0.01 ℃
  • Beaker volume1000 mL

Automatic Thermogravimetric Analyzer LTGA-A10

  •  Temperature rangeRoom temperature to 1000 ºC
  • Temperature resolution0.1 ºC
  • Temperature fluctuation±0.1 ºC
  • Heating rate1 ~ 80 ºC / min

Penetrometer LMPT-A10

  • Measurement range0 to 600 penetration scale
  • Timing controller5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec
  • Time accuracy± 0.1 seconds
  • Resolution0.01 mm

Penetrometer LMPT-A11

  • Measurement range0 to 600 penetration scale
  • Timing controller5 sec or 60 sec
  • Time accuracy± 0.1 seconds
  • Resolution0.01 mm
Penetrometer LMPT-A12
  • Penetrometer{"Measurement range":"0 to 600 penetration scale","Timing controller":"5 sec or 60 sec","Time accuracy":"\u00b1 0.1 seconds","Resolution":"0.1 penetration","Penetration accuracy":"\u00b1 1 penetration","Weight of standard needle":"2.5 \u00b1 0.05 g","Dimensions (W \u00d7 L \u00d7 H)":"700 \u00d7 400 \u00d7 750 mm","Weight":"30 kg"}
  • Circulatory Water Bath{"Bath volume":"3.5 L","Temperature range":"5 \u00b0C to 60 \u00b0C","Temperature accuracy":"\u00b1 0.1 \u00b0C","Circulatory water quantity":"3 L\/minute","Pump Lift":"2 m","Power consumption":"1200 W","Power supply":"AC 220V \u00b1 10 %, 50 Hz","Dimensions (W \u00d7 L \u00d7 H)":"600 \u00d7 400 \u00d7 650 mm","Weight":"40 kg"}
Penetrometer LMPT-A13
  • Measurement range0 to 600 penetration scale
  • Timing range0 sec to 60 sec
  • Time accuracy error≥ ± 0.1 seconds
  • Resolution0.1 penetration

Foaming Characteristics Tester LFCT-A10

  • Temperature RangeAmbient to 100°C
  • Temperature Precision± 0.1°C
  • Air Flow94 mL ± 5 mL/min, with flowmeters
  • Timing Unit0 to 99 min 59 s, resolution 1 s

Ash Content Tester LACT-A10

  • Electric Muffle Furnace{"Controlled\u00a0temperature":"775 \u00b125 \u2103","Temperature rising time of empty chamber":"\u2264 50 min","Furnace temperature uniformity":"\u2264 15\u2103","Internal dimension":"200 \u00d7 120 \u00d7 80 mm","External dimension":"490 \u00d7 490 \u00d7 450 mm","Power consumption":"2.5 kW","Power supply":"AC 220V \u00b110%, 50 Hz","Net weight":"35 kg"}
  • Temperature controller{"Maximum control temperature":"1200 \u2103","Dimension":"500 \u00d7 300 \u00d7 235 mm","Power consumption":"5000 W","Power supply":"AC 220\u00b110% V, 50Hz","Net weight":"5 kg"}
  • Electric heating plate{"Heating power":"(1 to 6) grades, continuously adjustable","Temperature":"400\u2103","Diameter of heating plate":"\u03a6 180 mm","Dimension":"280 \u00d7 250 \u00d7 90 mm","Power consumption":"2000 W","Power supply":"AC 220\u00b110%V, 50Hz"}

Mercaptan Sulfur Tester LMST-A10

  • Potential measuring range(0 to ±1999.5) Mv
  • Intrinsic error0.1 % ±0.5 mV
  • Input impedanceRi ≥1 × 1012 Ω
  • Burette capacity10 mL

Constant Temperature Needle Penetration Tester LTNP-A10

  • Measuring range0 to 700 taper degree (digital display table 0-70 mm)
  • Timing deviceTiming error is less than ±0.1 s
  •  Resolution0.01 mm
  • Needle insertion accuracy±1 cone insertion degree