ICP Spectrometer LICP-A11

ICP Spectrometer LICP-A11 detects micro and macro elements using argon plasma with an analyzing rate of 15 elements per minute. Results can be achieved with lower levels of detection for qualitative and quantitative analysis. Detection of liquid flow from the spray chamber by optical drain sensor offers exceptional sensitivity and accuracy. Accurate signal-background ratio is attained by advanced control system.

  • Wavelength range 180 to 900 nm
    Elements per minute 15 elements
    Temperature 29 °C
    Incident slit 25 µm
    Standard deviation RSD ≤ 2 %
    Correlation coefficient ≥ 0.9995 %
    Gas source Argon ( 99.99 % )
    Plasma gas flow meter 100 – 1000 L / h ( 1.6 - 16 L / min )
    Auxillary gas flow meter 10 – 100 L / h ( 0.16 – 1.66 L / min )
    Carrier gas flow meter 0 ~ 5 L / min
    Cooling water flow rate 5 L / min
    Cooling water temperature 20 ~ 26 °C
    Water outlet diameter 10 mm
    Line dispersion rate 0.26 nm
    Resolving power ≤ 0.007 nm
    Co-axial sprayer diameter 6 mm
    Coil diameter 25 mm
    Double room fog diameter 34 mm
    Quartz tube torch diameter 20 mm
    Mirror dimensions 80 x 110 x 16 mm
    • Rapid analysis – 15 elements per minute
    • Optical pathway – Czerny-turners
    • Low detection limit
    • Detection of multi-elements including non-metallic
    • Single and multi-element measurement method
    • Indication for wavelength error and repeatability
    • Range of measurement – common to trace
  • Used in clinical analysis for detection of metals in biological fluids , environmental analysis for trace element detection in water , soil , plants , pharmaceuticals for traces of catalysts and poison metals like Cd , Pb , industries for noble metal detection

ICP Spectrometer LICP-B10

  • {"Optical type":"Czerny turner","Resolution":"\u2264 0.015nm (3600 line grating) \u2264 0.030nm (2400 line grating)","Focal length":"1000 mm","Grating specifications":"huge holographic grating with 3600 L\/mil or 2400 L\/mil and 80 mm \u00d7 100 mm of ruling area","Wavelength range":"195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating"}Monochromator Specifications
  • {"Frequency":"27.12 MHz Frequency stability: < 0.05%","Spray chamber":"Scott double pass spray chamber","Output power":"800 W to 1600 W, adjustable with power efficiency more than 65%","Output power stability":"\u2264 0.05%","Induction coil":"25 mm \u00d7 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)"}Solid State Power Specifications
  • {"Suitable sample content range":"Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%","Repeatability":"short-term stability- RSD \u2264 1.5% Long-term stability: RSD \u2264 2%","Test speed":"5 to 8 elements \/ min","Limits of detection (LOD, \u00b5g\/L) for most elements":"1ppb to 10ppb"}Technical Specifications
  • {"Photomultiplier tube specification":"R212 \/ R928","Negative high voltage":"-50 to -1000 V","Circuit measuring range":"(10-12<\/sup> to 10 -4<\/sup>) A","Signal acquisition":"VF conversion"}Control Circuit

ICP Spectrometer LICP-A12

  • 195 to 800 mmWavelength range
  • 10 elementsElements per minute
  • 32 °CTemperature range
  • 20 µmIncident slit

ICP spectrometer LICP-A10

  • 180 to 500 nmWavelength range ( 3600 lines / mm )
  • 180 to 800 nmWavelength range ( 2400 lines / mm )
  • 20 ~ 28 °CTemperature
  • 26 elementsElements per minute

Handheld XRF Spectrometer LXRF-B10

  • Energy dispersive X-ray fluorescence analytical MethodAnalytical Method
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measuredElements Measuring
  • Simultaneous detectorRange
  • ppm to 100%Content measurement range

Handheld XRF Spectrometer LXRF-B11

  • Energy dispersive X-ray fluorescence analytical MethodAnalytical Method
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measuredElements Measuring
  • Simultaneous detectorRange
  • ppm to 99.99%Content measurement range
XRF-Spectrometer LXRF-A10
  • S to UMeasureable elements
  • 1 ppmDetection limit
  • 15 ~ 30 °CTemperature
  • 1 ppm to 99 %Elemental content
XRD Diffractometer LXRD-A10
  • Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kWX-ray Tuble
  • 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mmFocus Size
  • ≤ 0.01 %Stability
  • 5 to 80 mATube Current

Angular Spectrometer LASM-A10

  • 1inchAngle Measurement Accuracy
  • {"Focal Length":"170 mm","Effective Aperture":"\u03a6 22 mm","Field of View":"3\u00b0 22inch","Focal Length of Telescope\u2019s Eyepiece":"24.3 mm","Maximum Length Between Collimator and Telescope":"120 mm","Slit Width":"0.02 to 2 mm","Diopter Compensation Range":"\u2265 \u00b1 5 diopters"}Optical Parameter
  • {"Diameter":"\u03a6178 mm","Circle Graduation":"0\u00b0 to 360\u00b0","Division":"0.5\u00b0","Vernier Reading Value":"1inch"}Divided Circle
  • {"Diameter":"\u03a670 mm","Rotating Range":"360\u00b0","Range of Vertical Adjustment":"20 mm"}Stage

ICP spectrometer LICP-A10

  • 180 to 500 nmWavelength range ( 3600 lines / mm )
  • 180 to 800 nmWavelength range ( 2400 lines / mm )
  • 20 ~ 28 °CTemperature
  • 26 elementsElements per minute
ICP Spectrometer LICP-A11
  • 180 to 900 nmWavelength range
  • 15 elementsElements per minute
  • 29 °CTemperature
  • 25 µmIncident slit
ICP Spectrometer LICP-B10
  • {"Optical type":"Czerny turner","Resolution":"\u2264 0.015nm (3600 line grating) \u2264 0.030nm (2400 line grating)","Focal length":"1000 mm","Grating specifications":"huge holographic grating with 3600 L\/mil or 2400 L\/mil and 80 mm \u00d7 100 mm of ruling area","Wavelength range":"195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating"}Monochromator Specifications
  • {"Frequency":"27.12 MHz Frequency stability: < 0.05%","Spray chamber":"Scott double pass spray chamber","Output power":"800 W to 1600 W, adjustable with power efficiency more than 65%","Output power stability":"\u2264 0.05%","Induction coil":"25 mm \u00d7 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)"}Solid State Power Specifications
  • {"Suitable sample content range":"Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%","Repeatability":"short-term stability- RSD \u2264 1.5% Long-term stability: RSD \u2264 2%","Test speed":"5 to 8 elements \/ min","Limits of detection (LOD, \u00b5g\/L) for most elements":"1ppb to 10ppb"}Technical Specifications
  • {"Photomultiplier tube specification":"R212 \/ R928","Negative high voltage":"-50 to -1000 V","Circuit measuring range":"(10-12<\/sup> to 10 -4<\/sup>) A","Signal acquisition":"VF conversion"}Control Circuit

Atomic Fluorescence Spectrometer LAFS-A10

  • Dual ChannelBeam Configuration
  • {"As, Se, Pb, Bi, Sb, Te, Sn":"< 0.01 \u00b5g\/L","Hg, Cd":"< 0.001 \u00b5g\/L","Zn":"< 1.0 \u00b5g\/L","Ge":"< 0.1 \u00b5g\/L"}Elements ( Measuring Range )
  • < 1.0Precision ( RSD )
  • More than 3 orders of magnitudeLinear range