ICP Spectrometer LICP-B10

ICP Spectrometer LICP-B10 is an instrument which measures elements in ppb levels with least interference and reduces the time taken for analysis by detecting 5 to 6 elements in 1 min. Excellent analytical precision, high optical resolution, fully automated, wide wavelength range with 2400 line grating, powerful analysis software, high performance solid-state RF system, high accuracy etc. are some of the characteristic features. The equipment consist of a Scott-type spray chamber, quartz torch, spectrophotometer with Czerny-Turner monochromator, detector with photomultiplier tube and data processing system which allows multi-element measurement along with high resolution. It finds applications in environmental, food safety, metallurgy, pharmaceutical etc. fields.

  • Monochromator Specifications
    • Optical type: Czerny turner
    • Resolution: ≤ 0.015nm (3600 line grating)<br/> ≤ 0.030nm (2400 line grating)
    • Focal length: 1000 mm
    • Grating specifications: huge holographic grating with 3600 L/mil or 2400 L/mil and 80 mm × 100 mm of ruling area
    • Wavelength range: 195 to 500 nm for 3600 line grating<br/> 195 to 800 nm for 2400 line grating
    Solid State Power Specifications
    • Frequency: 27.12 MHz<br/> Frequency stability: < 0.05%
    • Spray chamber: Scott double pass spray chamber
    • Output power: 800 W to 1600 W, adjustable with power efficiency more than 65%
    • Output power stability: ≤ 0.05%
    • Induction coil: 25 mm × 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)
    Technical Specifications
    • Suitable sample content range: Liquid sample: 0.01 ppm to several thousand ppm<br/> Solid or power sample: 0.001% to 70%
    • Repeatability: short-term stability- RSD ≤ 1.5%<br/> Long-term stability: RSD ≤ 2%
    • Test speed: 5 to 8 elements / min
    • Limits of detection (LOD, µg/L) for most elements: 1ppb to 10ppb
    Control Circuit
    • Photomultiplier tube specification: R212 / R928
    • Negative high voltage: -50 to -1000 V
    • Circuit measuring range: (10<sup>-12</sup> to 10 <sup>-4</sup>) A
    • Signal acquisition: VF conversion
    Working Environment
    • Temperature for storage and transportation: 15°C to 25°C
    • Humidity for storage and transportation: ≤ 70%
    • Power Stability: 220 ± 10V; 50 to 60 V
    • Humidity: ≤ 70%
    • Temperature: 15°C to 30°C
    Other Details
    • Packaging Dimension and Gross Weight (4 case): 1st case: 188 × 111 × 105 / 348 kg<br/> 2nd case: 60 × 60 × 55 / 25 kg<br/> 3rd case: 59 × 67 × 97 / 80 kg<br/> 4th case: 38.5 × 38.5 × 63 / 47 kg
    • Highly advance optical design
    • Holographic grating for minimum scattering of light
    • Correction of spectral interference to improvise detection
    • System controlled torch movement for optimized position
    • System controlled mass flow controller for carrier gas, auxiliary gas and plasma gas
    • 27.12 MHz RF generator for efficient ionization
    • Auto-coupling system
    • Peristaltic pump for stable flow rate and drainage of sample
    • Argon gas cylinder last up to 8 hours
      Auto-sampler can be provided
    • Software Details
    • Allows selection of multiple elements and parameters for analysis
    • Faster Calibration function
    • Correction of background interference
    • Report generation with single button press
    • Many export options
    • Real-time graphical display of instrument status
    • Plasma ignition with one button press
    • Large database to select spectral lines according to requirement
  • It used for quantitative and qualitative analysis of elements in the given sample. Various fields like petrochemicals, pharmaceuticals, agriculture, environmental, food industry, metallurgy, processing industry etc. require it for several operations.

  • Accessories No Accessories Name
    1 Gas pressure regulator
    2 Water cooling system
    3 Voltage stabilizer
    4 ICP 2060T power cable
    5 Copper cable for ground
    6 Sampling system: nebulizer, spray chamber, plasma torch
  • Auto-sampler

ICP Spectrometer LICP-A12

  • 195 to 800 mmWavelength range
  • 10 elementsElements per minute
  • 32 °CTemperature range
  • 20 µmIncident slit

ICP Spectrometer LICP-A11

  • 180 to 900 nmWavelength range
  • 15 elementsElements per minute
  • 29 °CTemperature
  • 25 µmIncident slit

ICP spectrometer LICP-A10

  • 180 to 500 nmWavelength range ( 3600 lines / mm )
  • 180 to 800 nmWavelength range ( 2400 lines / mm )
  • 20 ~ 28 °CTemperature
  • 26 elementsElements per minute

ICP spectrometer LICP-A10

  • 180 to 500 nmWavelength range ( 3600 lines / mm )
  • 180 to 800 nmWavelength range ( 2400 lines / mm )
  • 20 ~ 28 °CTemperature
  • 26 elementsElements per minute

ICP Spectrometer LICP-B10

  • {"Optical type":"Czerny turner","Resolution":"\u2264 0.015nm (3600 line grating) \u2264 0.030nm (2400 line grating)","Focal length":"1000 mm","Grating specifications":"huge holographic grating with 3600 L\/mil or 2400 L\/mil and 80 mm \u00d7 100 mm of ruling area","Wavelength range":"195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating"}Monochromator Specifications
  • {"Frequency":"27.12 MHz Frequency stability: < 0.05%","Spray chamber":"Scott double pass spray chamber","Output power":"800 W to 1600 W, adjustable with power efficiency more than 65%","Output power stability":"\u2264 0.05%","Induction coil":"25 mm \u00d7 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)"}Solid State Power Specifications
  • {"Suitable sample content range":"Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%","Repeatability":"short-term stability- RSD \u2264 1.5% Long-term stability: RSD \u2264 2%","Test speed":"5 to 8 elements \/ min","Limits of detection (LOD, \u00b5g\/L) for most elements":"1ppb to 10ppb"}Technical Specifications
  • {"Photomultiplier tube specification":"R212 \/ R928","Negative high voltage":"-50 to -1000 V","Circuit measuring range":"(10-12<\/sup> to 10 -4<\/sup>) A","Signal acquisition":"VF conversion"}Control Circuit
ICP Spectrometer LICP-A11
  • 180 to 900 nmWavelength range
  • 15 elementsElements per minute
  • 29 °CTemperature
  • 25 µmIncident slit
FTIR Spectrometer LIR-B10
  • 7800 cm-1 to 350 cm-1 Spectral Range
  • 0.85 cm-1 Resolution
  • ± 0.01 cm-1 Wave number precision
  • Microprocessor control, different scanning speed selectableScanning speed

Atomic Fluorescence Spectrometer LAFS-A10

  • Dual ChannelBeam Configuration
  • {"As, Se, Pb, Bi, Sb, Te, Sn":"< 0.01 \u00b5g\/L","Hg, Cd":"< 0.001 \u00b5g\/L","Zn":"< 1.0 \u00b5g\/L","Ge":"< 0.1 \u00b5g\/L"}Elements ( Measuring Range )
  • < 1.0Precision ( RSD )
  • More than 3 orders of magnitudeLinear range

Handheld XRF Spectrometer LXRF-B10

  • Energy dispersive X-ray fluorescence analytical MethodAnalytical Method
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measuredElements Measuring
  • Simultaneous detectorRange
  • ppm to 100%Content measurement range
XRF-Spectrometer LXRF-A10
  • S to UMeasureable elements
  • 1 ppmDetection limit
  • 15 ~ 30 °CTemperature
  • 1 ppm to 99 %Elemental content
Handheld XRF Spectrometer LXRF-B11
  • Energy dispersive X-ray fluorescence analytical MethodAnalytical Method
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measuredElements Measuring
  • Simultaneous detectorRange
  • ppm to 99.99%Content measurement range

Angular Spectrometer LASM-A10

  • 1inchAngle Measurement Accuracy
  • {"Focal Length":"170 mm","Effective Aperture":"\u03a6 22 mm","Field of View":"3\u00b0 22inch","Focal Length of Telescope\u2019s Eyepiece":"24.3 mm","Maximum Length Between Collimator and Telescope":"120 mm","Slit Width":"0.02 to 2 mm","Diopter Compensation Range":"\u2265 \u00b1 5 diopters"}Optical Parameter
  • {"Diameter":"\u03a6178 mm","Circle Graduation":"0\u00b0 to 360\u00b0","Division":"0.5\u00b0","Vernier Reading Value":"1inch"}Divided Circle
  • {"Diameter":"\u03a670 mm","Rotating Range":"360\u00b0","Range of Vertical Adjustment":"20 mm"}Stage