\u2264 0.030nm (2400 line grating)","Focal length":"1000 mm","Grating specifications":"huge holographic grating with 3600 L\/mil or 2400 L\/mil and 80 mm \u00d7 100 mm of ruling area","Wavelength range":"195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating"}, Solid State Power Specifications: {"Frequency":"27.12 MHz Frequency stability: < 0.05%","Spray chamber":"Scott double pass spray chamber","Output power":"800 W to 1600 W, adjustable with power efficiency more than 65%","Output power stability":"\u2264 0.05%","Induction coil":"25 mm \u00d7 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)"}, Technical Specifications: {"Suitable sample content range":"Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%","Repeatability":"short-term stability- RSD \u2264 1.5% Long-term stability: RSD \u2264 2%","Test speed":"5 to 8 elements \/ min","Limits of detection (LOD, \u00b5g\/L) for most elements":"1ppb to 10ppb"}. Explore the product to find out more. Visit Labtron.best!"> ICP Spectrometer LICP-B10 Catalog | Labtron \u2264 0.030nm (2400 line grating)","Focal length":"1000 mm","Grating specifications":"huge holographic grating with 3600 L\/mil or 2400 L\/mil and 80 mm \u00d7 100 mm of ruling area","Wavelength range":"195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating"}, Solid State Power Specifications: {"Frequency":"27.12 MHz Frequency stability: < 0.05%","Spray chamber":"Scott double pass spray chamber","Output power":"800 W to 1600 W, adjustable with power efficiency more than 65%","Output power stability":"\u2264 0.05%","Induction coil":"25 mm \u00d7 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)"}, Technical Specifications: {"Suitable sample content range":"Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%","Repeatability":"short-term stability- RSD \u2264 1.5% Long-term stability: RSD \u2264 2%","Test speed":"5 to 8 elements \/ min","Limits of detection (LOD, \u00b5g\/L) for most elements":"1ppb to 10ppb"}. Explore the product to find out more. Visit Labtron.best!"> \u2264 0.030nm (2400 line grating)","Focal length":"1000 mm","Grating specifications":"huge holographic grating with 3600 L\/mil or 2400 L\/mil and 80 mm \u00d7 100 mm of ruling area","Wavelength range":"195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating"}, Solid State Power Specifications: {"Frequency":"27.12 MHz Frequency stability: < 0.05%","Spray chamber":"Scott double pass spray chamber","Output power":"800 W to 1600 W, adjustable with power efficiency more than 65%","Output power stability":"\u2264 0.05%","Induction coil":"25 mm \u00d7 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)"}, Technical Specifications: {"Suitable sample content range":"Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%","Repeatability":"short-term stability- RSD \u2264 1.5% Long-term stability: RSD \u2264 2%","Test speed":"5 to 8 elements \/ min","Limits of detection (LOD, \u00b5g\/L) for most elements":"1ppb to 10ppb"}. Explore the product to find out more. Visit Labtron.best!">

ICP Spectrometer LICP-B10 Catalog

Overview

ICP Spectrometer LICP-B10 is an instrument which measures elements in ppb levels with least interference and reduces the time taken for analysis by detecting 5 to 6 elements in 1 min. Excellent analytical precision, high optical resolution, fully automated, wide wavelength range with 2400 line grating, powerful analysis software, high performance solid-state RF system, high accuracy etc. are some of the characteristic features. The equipment consist of a Scott-type spray chamber, quartz torch, spectrophotometer with Czerny-Turner monochromator, detector with photomultiplier tube and data processing system which allows multi-element measurement along with high resolution. It finds applications in environmental, food safety, metallurgy, pharmaceutical etc. fields.

Specifications
Monochromator Specifications
  • Optical type: Czerny turner
  • Resolution: ≤ 0.015nm (3600 line grating)<br/> ≤ 0.030nm (2400 line grating)
  • Focal length: 1000 mm
  • Grating specifications: huge holographic grating with 3600 L/mil or 2400 L/mil and 80 mm × 100 mm of ruling area
  • Wavelength range: 195 to 500 nm for 3600 line grating<br/> 195 to 800 nm for 2400 line grating
Solid State Power Specifications
  • Frequency: 27.12 MHz<br/> Frequency stability: < 0.05%
  • Spray chamber: Scott double pass spray chamber
  • Output power: 800 W to 1600 W, adjustable with power efficiency more than 65%
  • Output power stability: ≤ 0.05%
  • Induction coil: 25 mm × 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)
Technical Specifications
  • Suitable sample content range: Liquid sample: 0.01 ppm to several thousand ppm<br/> Solid or power sample: 0.001% to 70%
  • Repeatability: short-term stability- RSD ≤ 1.5%<br/> Long-term stability: RSD ≤ 2%
  • Test speed: 5 to 8 elements / min
  • Limits of detection (LOD, µg/L) for most elements: 1ppb to 10ppb
Control Circuit
  • Photomultiplier tube specification: R212 / R928
  • Negative high voltage: -50 to -1000 V
  • Circuit measuring range: (10<sup>-12</sup> to 10 <sup>-4</sup>) A
  • Signal acquisition: VF conversion
Working Environment
  • Temperature for storage and transportation: 15°C to 25°C
  • Humidity for storage and transportation: ≤ 70%
  • Power Stability: 220 ± 10V; 50 to 60 V
  • Humidity: ≤ 70%
  • Temperature: 15°C to 30°C
Other Details
  • Packaging Dimension and Gross Weight (4 case): 1st case: 188 × 111 × 105 / 348 kg<br/> 2nd case: 60 × 60 × 55 / 25 kg<br/> 3rd case: 59 × 67 × 97 / 80 kg<br/> 4th case: 38.5 × 38.5 × 63 / 47 kg

Features

  • Highly advance optical design
  • Holographic grating for minimum scattering of light
  • Correction of spectral interference to improvise detection
  • System controlled torch movement for optimized position
  • System controlled mass flow controller for carrier gas, auxiliary gas and plasma gas
  • 27.12 MHz RF generator for efficient ionization
  • Auto-coupling system
  • Peristaltic pump for stable flow rate and drainage of sample
  • Argon gas cylinder last up to 8 hours
    Auto-sampler can be provided
  • Software Details
  • Allows selection of multiple elements and parameters for analysis
  • Faster Calibration function
  • Correction of background interference
  • Report generation with single button press
  • Many export options
  • Real-time graphical display of instrument status
  • Plasma ignition with one button press
  • Large database to select spectral lines according to requirement
Standard Accessories :

Accessories No Accessories Name
1 Gas pressure regulator
2 Water cooling system
3 Voltage stabilizer
4 ICP 2060T power cable
5 Copper cable for ground
6 Sampling system: nebulizer, spray chamber, plasma torch

Optional Accessories :

Auto-sampler

Applications :

It used for quantitative and qualitative analysis of elements in the given sample. Various fields like petrochemicals, pharmaceuticals, agriculture, environmental, food industry, metallurgy, processing industry etc. require it for several operations.