Angular Spectrometer LASM-A10

Angular Spectrometer LASM-A10 is a tabletop unit, offers angle measurement accuracy of 1 inch and diopter compensation range of ≥ ± 5 diopters. Incorporated with two verniers at the opposite edges, to remove errors induced by the off center errors of the divided circle and thrusting bearing under the divided circle for smooth rotation. Equipped with magnifier with handle, optical parallel plate and planar holographic grating. Built in with adjustable dioptre, moveable telescopes eyepiece and adjustable stage.

  • Angle Measurement Accuracy 1inch
    Optical Parameter
    • Focal Length: 170 mm
    • Effective Aperture: Φ 22 mm
    • Field of View: 3° 22inch
    • Focal Length of Telescope’s Eyepiece: 24.3 mm
    • Maximum Length Between Collimator and Telescope: 120 mm
    • Slit Width: 0.02 to 2 mm
    • Diopter Compensation Range: ≥ ± 5 diopters
    Divided Circle
    • Diameter: Φ178 mm
    • Circle Graduation: 0° to 360°
    • Division: 0.5°
    • Vernier Reading Value: 1inch
    Stage
    • Diameter: Φ70 mm
    • Rotating Range: 360°
    • Range of Vertical Adjustment: 20 mm
    Attachments
    • Prism Angle: 60° ± 5inch
    • Transformer: 6.3 Ⅴ/220 Ⅴ (3 ⅤA)
    • Planar Holographic Grating: 300/ mm
    Dimensions (W×D×H) 251×518×250 mm
    Net Weight 11.8 kg
    • Highly efficient and safe with complete functions
    • Easy to clean, corrosion resistant, stainless steel lining
    • Compact and space saving design
    • Easy to use, operate and less maintenance
    • Built in with fine adjusting knob of telescope, collimator unit and brake mount
  • Angular Spectrometer is widely used for angular measurements based on polarization, diffraction, refraction and interference. It is commonly used in color measurements, concentration determination of chemical components and electromagnetic radiation analysis.

FTIR Spectrometer LIR-B10

  • 7800 cm-1 to 350 cm-1 Spectral Range
  • 0.85 cm-1 Resolution
  • ± 0.01 cm-1 Wave number precision
  • Microprocessor control, different scanning speed selectableScanning speed

Angular Spectrometer LASM-A10

  • 1inchAngle Measurement Accuracy
  • {"Focal Length":"170 mm","Effective Aperture":"\u03a6 22 mm","Field of View":"3\u00b0 22inch","Focal Length of Telescope\u2019s Eyepiece":"24.3 mm","Maximum Length Between Collimator and Telescope":"120 mm","Slit Width":"0.02 to 2 mm","Diopter Compensation Range":"\u2265 \u00b1 5 diopters"}Optical Parameter
  • {"Diameter":"\u03a6178 mm","Circle Graduation":"0\u00b0 to 360\u00b0","Division":"0.5\u00b0","Vernier Reading Value":"1inch"}Divided Circle
  • {"Diameter":"\u03a670 mm","Rotating Range":"360\u00b0","Range of Vertical Adjustment":"20 mm"}Stage
Atomic Fluorescence Spectrometer LAFS-A10
  • Dual ChannelBeam Configuration
  • {"As, Se, Pb, Bi, Sb, Te, Sn":"< 0.01 \u00b5g\/L","Hg, Cd":"< 0.001 \u00b5g\/L","Zn":"< 1.0 \u00b5g\/L","Ge":"< 0.1 \u00b5g\/L"}Elements ( Measuring Range )
  • < 1.0Precision ( RSD )
  • More than 3 orders of magnitudeLinear range
XRD Diffractometer LXRD-A10
  • Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kWX-ray Tuble
  • 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mmFocus Size
  • ≤ 0.01 %Stability
  • 5 to 80 mATube Current

ICP Spectrometer LICP-A11

  • 180 to 900 nmWavelength range
  • 15 elementsElements per minute
  • 29 °CTemperature
  • 25 µmIncident slit

ICP Spectrometer LICP-B10

  • {"Optical type":"Czerny turner","Resolution":"\u2264 0.015nm (3600 line grating) \u2264 0.030nm (2400 line grating)","Focal length":"1000 mm","Grating specifications":"huge holographic grating with 3600 L\/mil or 2400 L\/mil and 80 mm \u00d7 100 mm of ruling area","Wavelength range":"195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating"}Monochromator Specifications
  • {"Frequency":"27.12 MHz Frequency stability: < 0.05%","Spray chamber":"Scott double pass spray chamber","Output power":"800 W to 1600 W, adjustable with power efficiency more than 65%","Output power stability":"\u2264 0.05%","Induction coil":"25 mm \u00d7 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)"}Solid State Power Specifications
  • {"Suitable sample content range":"Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%","Repeatability":"short-term stability- RSD \u2264 1.5% Long-term stability: RSD \u2264 2%","Test speed":"5 to 8 elements \/ min","Limits of detection (LOD, \u00b5g\/L) for most elements":"1ppb to 10ppb"}Technical Specifications
  • {"Photomultiplier tube specification":"R212 \/ R928","Negative high voltage":"-50 to -1000 V","Circuit measuring range":"(10-12<\/sup> to 10 -4<\/sup>) A","Signal acquisition":"VF conversion"}Control Circuit
ICP spectrometer LICP-A10
  • 180 to 500 nmWavelength range ( 3600 lines / mm )
  • 180 to 800 nmWavelength range ( 2400 lines / mm )
  • 20 ~ 28 °CTemperature
  • 26 elementsElements per minute