XRF-Spectrometer LXRF-A10

XRF-Spectrometer LXRF-A10 is a microprocessor controlled high-count throughput unit with low detection limits for wide range of elements. Provision of multi-elemental analysis with detection limits upto 1 ppm. Built-in movable platform for easy location of testing point.High resolution detector improves analysis accuracy. Equipped with safety features of optical tube shielding with no X-ray radiation and high voltage emergency locking.

  • Measureable elements S to U
    Detection limit 1 ppm
    Temperature 15 ~ 30 °C
    Elemental content 1 ppm to 99 %
    Repeatability 0.001
    Stability 0.001
    Power supply AC 220 V ± 5 V
    Dimensions 550 x 410 x 320 mm
    Weight 45 kg
    • Detection limit – 1 ppm
    • Measureable elements – S to U
    • Elemental content – 1 ppm to 99 %
    • Movable sample platform for easy detection of testing point
    • Built-in electric cooling Si-PIN detector
    • Safety features - optical tube shielding with no X-ray radiation and high voltage emergency locking
  • Used in detection of plating thickness of metals, concentration of plating solution , RoHS detection and analysis, full-element analysis and electro plating industries

Handheld XRF Spectrometer LXRF-B11

  • Energy dispersive X-ray fluorescence analytical MethodAnalytical Method
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measuredElements Measuring
  • Simultaneous detectorRange
  • ppm to 99.99%Content measurement range

Handheld XRF Spectrometer LXRF-B10

  • Energy dispersive X-ray fluorescence analytical MethodAnalytical Method
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measuredElements Measuring
  • Simultaneous detectorRange
  • ppm to 100%Content measurement range

ICP spectrometer LICP-A10

  • 180 to 500 nmWavelength range ( 3600 lines / mm )
  • 180 to 800 nmWavelength range ( 2400 lines / mm )
  • 20 ~ 28 °CTemperature
  • 26 elementsElements per minute

ICP Spectrometer LICP-B10

  • {"Optical type":"Czerny turner","Resolution":"\u2264 0.015nm (3600 line grating) \u2264 0.030nm (2400 line grating)","Focal length":"1000 mm","Grating specifications":"huge holographic grating with 3600 L\/mil or 2400 L\/mil and 80 mm \u00d7 100 mm of ruling area","Wavelength range":"195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating"}Monochromator Specifications
  • {"Frequency":"27.12 MHz Frequency stability: < 0.05%","Spray chamber":"Scott double pass spray chamber","Output power":"800 W to 1600 W, adjustable with power efficiency more than 65%","Output power stability":"\u2264 0.05%","Induction coil":"25 mm \u00d7 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)"}Solid State Power Specifications
  • {"Suitable sample content range":"Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%","Repeatability":"short-term stability- RSD \u2264 1.5% Long-term stability: RSD \u2264 2%","Test speed":"5 to 8 elements \/ min","Limits of detection (LOD, \u00b5g\/L) for most elements":"1ppb to 10ppb"}Technical Specifications
  • {"Photomultiplier tube specification":"R212 \/ R928","Negative high voltage":"-50 to -1000 V","Circuit measuring range":"(10-12<\/sup> to 10 -4<\/sup>) A","Signal acquisition":"VF conversion"}Control Circuit
ICP Spectrometer LICP-A11
  • 180 to 900 nmWavelength range
  • 15 elementsElements per minute
  • 29 °CTemperature
  • 25 µmIncident slit
Angular Spectrometer LASM-A10
  • 1inchAngle Measurement Accuracy
  • {"Focal Length":"170 mm","Effective Aperture":"\u03a6 22 mm","Field of View":"3\u00b0 22inch","Focal Length of Telescope\u2019s Eyepiece":"24.3 mm","Maximum Length Between Collimator and Telescope":"120 mm","Slit Width":"0.02 to 2 mm","Diopter Compensation Range":"\u2265 \u00b1 5 diopters"}Optical Parameter
  • {"Diameter":"\u03a6178 mm","Circle Graduation":"0\u00b0 to 360\u00b0","Division":"0.5\u00b0","Vernier Reading Value":"1inch"}Divided Circle
  • {"Diameter":"\u03a670 mm","Rotating Range":"360\u00b0","Range of Vertical Adjustment":"20 mm"}Stage

Atomic Fluorescence Spectrometer LAFS-A10

  • Dual ChannelBeam Configuration
  • {"As, Se, Pb, Bi, Sb, Te, Sn":"< 0.01 \u00b5g\/L","Hg, Cd":"< 0.001 \u00b5g\/L","Zn":"< 1.0 \u00b5g\/L","Ge":"< 0.1 \u00b5g\/L"}Elements ( Measuring Range )
  • < 1.0Precision ( RSD )
  • More than 3 orders of magnitudeLinear range

XRD Diffractometer LXRD-A10

  • Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kWX-ray Tuble
  • 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mmFocus Size
  • ≤ 0.01 %Stability
  • 5 to 80 mATube Current
Handheld XRF Spectrometer LXRF-B11
  • Energy dispersive X-ray fluorescence analytical MethodAnalytical Method
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measuredElements Measuring
  • Simultaneous detectorRange
  • ppm to 99.99%Content measurement range
Handheld XRF Spectrometer LXRF-B10
  • Energy dispersive X-ray fluorescence analytical MethodAnalytical Method
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measuredElements Measuring
  • Simultaneous detectorRange
  • ppm to 100%Content measurement range

XRF-Spectrometer LXRF-A10

  • S to UMeasureable elements
  • 1 ppmDetection limit
  • 15 ~ 30 °CTemperature
  • 1 ppm to 99 %Elemental content