Atomic Fluorescence Spectrometer LAFS-A10

Atomic Fluorescence Spectrometer LAFS-A10 is a microprocessor controlled double-channel, non-dispersive unit used for trace element composition, ultra-trace analysis of Mercury and all other hydride-forming elements. Pre adjusted referral optical plane to coincide atomizer center with optical focus. Equipped with a feature of real time conversion of data into graph.

  • Beam Configuration Dual Channel
    Elements ( Measuring Range )
    • As, Se, Pb, Bi, Sb, Te, Sn: < 0.01 µg/L
    • Hg, Cd: < 0.001 µg/L
    • Zn: < 1.0 µg/L
    • Ge: < 0.1 µg/L
    Precision ( RSD ) < 1.0
    Linear range More than 3 orders of magnitude
    Lamp Hollow cathode lamp
    Power Supply 220 V
    Dimension 1000 x 350 x 390 mm
    Weight 70 Kg
    • Double channel detection for trace element analysis
    • Peak height and peak area integral detection method
    • High stability light source
    • High intensity hollow cathode lamps for high sensitivity and stability
    • Gas - liquid separator for improved repeatability of results
    • Double shielded quartz atomizer with automatic igniting argon – hydrogen flame
    • Stable gas flow
    • Automatic gas alarm pressure at critical point
    • USB communication for real time automatic detection
  • Used in analysis / detection of compound present in air of water, heavy metal detection, redirect photons , in various fields of geology, metallurgy, medicine, chemical industry, food inspection, water supply, waste water treatment and scientific research.

XRD Diffractometer LXRD-A10

  • Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kWX-ray Tuble
  • 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mmFocus Size
  • ≤ 0.01 %Stability
  • 5 to 80 mATube Current

Atomic Fluorescence Spectrometer LAFS-A10

  • Dual ChannelBeam Configuration
  • {"As, Se, Pb, Bi, Sb, Te, Sn":"< 0.01 \u00b5g\/L","Hg, Cd":"< 0.001 \u00b5g\/L","Zn":"< 1.0 \u00b5g\/L","Ge":"< 0.1 \u00b5g\/L"}Elements ( Measuring Range )
  • < 1.0Precision ( RSD )
  • More than 3 orders of magnitudeLinear range
FTIR Spectrometer LIR-B10
  • 7800 cm-1 to 350 cm-1 Spectral Range
  • 0.85 cm-1 Resolution
  • ± 0.01 cm-1 Wave number precision
  • Microprocessor control, different scanning speed selectableScanning speed
ICP Spectrometer LICP-B10
  • {"Optical type":"Czerny turner","Resolution":"\u2264 0.015nm (3600 line grating) \u2264 0.030nm (2400 line grating)","Focal length":"1000 mm","Grating specifications":"huge holographic grating with 3600 L\/mil or 2400 L\/mil and 80 mm \u00d7 100 mm of ruling area","Wavelength range":"195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating"}Monochromator Specifications
  • {"Frequency":"27.12 MHz Frequency stability: < 0.05%","Spray chamber":"Scott double pass spray chamber","Output power":"800 W to 1600 W, adjustable with power efficiency more than 65%","Output power stability":"\u2264 0.05%","Induction coil":"25 mm \u00d7 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)"}Solid State Power Specifications
  • {"Suitable sample content range":"Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%","Repeatability":"short-term stability- RSD \u2264 1.5% Long-term stability: RSD \u2264 2%","Test speed":"5 to 8 elements \/ min","Limits of detection (LOD, \u00b5g\/L) for most elements":"1ppb to 10ppb"}Technical Specifications
  • {"Photomultiplier tube specification":"R212 \/ R928","Negative high voltage":"-50 to -1000 V","Circuit measuring range":"(10-12<\/sup> to 10 -4<\/sup>) A","Signal acquisition":"VF conversion"}Control Circuit

ICP spectrometer LICP-A10

  • 180 to 500 nmWavelength range ( 3600 lines / mm )
  • 180 to 800 nmWavelength range ( 2400 lines / mm )
  • 20 ~ 28 °CTemperature
  • 26 elementsElements per minute

ICP Spectrometer LICP-A11

  • 180 to 900 nmWavelength range
  • 15 elementsElements per minute
  • 29 °CTemperature
  • 25 µmIncident slit
Handheld XRF Spectrometer LXRF-B11
  • Energy dispersive X-ray fluorescence analytical MethodAnalytical Method
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measuredElements Measuring
  • Simultaneous detectorRange
  • ppm to 99.99%Content measurement range
XRF-Spectrometer LXRF-A10
  • S to UMeasureable elements
  • 1 ppmDetection limit
  • 15 ~ 30 °CTemperature
  • 1 ppm to 99 %Elemental content

Handheld XRF Spectrometer LXRF-B10

  • Energy dispersive X-ray fluorescence analytical MethodAnalytical Method
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measuredElements Measuring
  • Simultaneous detectorRange
  • ppm to 100%Content measurement range