XRD Diffractometer LXRD-A10

XRD Diffractometer LXRD-A10 contains tube current up to 5 to 80 mA with a dimension 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm and are designed for quality diffraction data, combined with ease of use and flexibility to quickly switch to different applications, This multipurpose diffractometers are all equipped with X-ray tuble of glass tube, ceramic tube, ripple ceramic tube with many different X-ray source materials (Cu, Fe, Co, Cr and Mo) and is coupled with an auto-switching dual wavelength optic. It have Low maintenance, high performance system and designed with Horizontal Goniometer structure and proportional/Scintillation counters detector.

  • X-ray Tuble Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kW
    Focus Size 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm
    Stability ≤ 0.01 %
    Tube Current 5 to 80 mA
    Tube Voltage 10 to 60 kV
    Rated Power 3 kW
    Goniometer Structure Horizontal (Ø to 2 Ø )
    Radius of Diffraction 185 mm
    Scanning Range 0 to 164
    Scanning Speed 0.0012º to 70 º min
    Maximum Resolving Speed 100 º / min
    Scanning Mode Ø to 2 Ø linkage, Ø, 2 Ø single action; continuous/stepping scanning
    Angle Repeatable Accuracy 1 / 1000 º
    Minimal Stepping Angle 1 / 1000 º
    Detector Proportional/Scintillation counters
    Maximum Counting rate of Linearity 5 × 10<sup>5 </sup> CPS (with the compensate function of dropout counting)
    Energy Resolution Ratio ≤ 25 % (PC), ≤ 50 % (SC)
    Counting Fashion Differential Coefficient / integral, PHA automatically, Dead time regulate
    Stability of System measure ≤ 0.01 %
    Scattered Rays Dose ≤ 1 µ Sv/h (without X-ray protective device)
    Instrument Integrative Stability ≤ 0.5 %
    Dimension 1100 × 850 × 1750 mm
    Weight About 25 kg
    • Diffractometer is equipped with X-ray tuble of glass tube, ceramic tube, and ripple ceramic tube with many different X-ray source materials (Cu, Fe, Co, Cr and Mo)
    • Coupled with an auto-switching dual wavelength optic
    • Horizontal Goniometer structure
    • Proportional/Scintillation counters detector
    • For testing unknown samples it has phase identification and phase analysis for known mixed samples
    • Crystal structure varies with temperature (high temperature vice versa) factor and chemical information tested by X-ray diffraction test device
    • Equipped with programmable operation, integrated structure design with easy operation and well-designed outlook
    • High throughput with high accuracy diffraction angle measurement
    • Scanning range and Scanning speed are well design in equipment
  • Best suited for the research and industrial product analysis with perfect combination of conventional analysis crucial measurement product and for academics and researchers in different application areas.

ICP spectrometer LICP-A10

  • 180 to 500 nmWavelength range ( 3600 lines / mm )
  • 180 to 800 nmWavelength range ( 2400 lines / mm )
  • 20 ~ 28 °CTemperature
  • 26 elementsElements per minute

ICP Spectrometer LICP-A11

  • 180 to 900 nmWavelength range
  • 15 elementsElements per minute
  • 29 °CTemperature
  • 25 µmIncident slit
ICP Spectrometer LICP-B10
  • {"Optical type":"Czerny turner","Resolution":"\u2264 0.015nm (3600 line grating) \u2264 0.030nm (2400 line grating)","Focal length":"1000 mm","Grating specifications":"huge holographic grating with 3600 L\/mil or 2400 L\/mil and 80 mm \u00d7 100 mm of ruling area","Wavelength range":"195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating"}Monochromator Specifications
  • {"Frequency":"27.12 MHz Frequency stability: < 0.05%","Spray chamber":"Scott double pass spray chamber","Output power":"800 W to 1600 W, adjustable with power efficiency more than 65%","Output power stability":"\u2264 0.05%","Induction coil":"25 mm \u00d7 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)"}Solid State Power Specifications
  • {"Suitable sample content range":"Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%","Repeatability":"short-term stability- RSD \u2264 1.5% Long-term stability: RSD \u2264 2%","Test speed":"5 to 8 elements \/ min","Limits of detection (LOD, \u00b5g\/L) for most elements":"1ppb to 10ppb"}Technical Specifications
  • {"Photomultiplier tube specification":"R212 \/ R928","Negative high voltage":"-50 to -1000 V","Circuit measuring range":"(10-12<\/sup> to 10 -4<\/sup>) A","Signal acquisition":"VF conversion"}Control Circuit
Handheld XRF Spectrometer LXRF-B11
  • Energy dispersive X-ray fluorescence analytical MethodAnalytical Method
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measuredElements Measuring
  • Simultaneous detectorRange
  • ppm to 99.99%Content measurement range

Handheld XRF Spectrometer LXRF-B10

  • Energy dispersive X-ray fluorescence analytical MethodAnalytical Method
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measuredElements Measuring
  • Simultaneous detectorRange
  • ppm to 100%Content measurement range

XRF-Spectrometer LXRF-A10

  • S to UMeasureable elements
  • 1 ppmDetection limit
  • 15 ~ 30 °CTemperature
  • 1 ppm to 99 %Elemental content
FTIR Spectrometer LIR-B10
  • 7800 cm-1 to 350 cm-1 Spectral Range
  • 0.85 cm-1 Resolution
  • ± 0.01 cm-1 Wave number precision
  • Microprocessor control, different scanning speed selectableScanning speed
XRD Diffractometer LXRD-A10
  • Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kWX-ray Tuble
  • 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mmFocus Size
  • ≤ 0.01 %Stability
  • 5 to 80 mATube Current

Angular Spectrometer LASM-A10

  • 1inchAngle Measurement Accuracy
  • {"Focal Length":"170 mm","Effective Aperture":"\u03a6 22 mm","Field of View":"3\u00b0 22inch","Focal Length of Telescope\u2019s Eyepiece":"24.3 mm","Maximum Length Between Collimator and Telescope":"120 mm","Slit Width":"0.02 to 2 mm","Diopter Compensation Range":"\u2265 \u00b1 5 diopters"}Optical Parameter
  • {"Diameter":"\u03a6178 mm","Circle Graduation":"0\u00b0 to 360\u00b0","Division":"0.5\u00b0","Vernier Reading Value":"1inch"}Divided Circle
  • {"Diameter":"\u03a670 mm","Rotating Range":"360\u00b0","Range of Vertical Adjustment":"20 mm"}Stage