Handheld XRF Spectrometer LXRF-B10 (XRF stands for X-ray fluorescence) comes in special three level military-protection-box, which is compression free, moisture-proof and shockproof for convenient handling and for on field analysis. Rechargeable lithium battery 9000 mAh, sustainable work up to 12 hours. The core parts are Miniature X-ray tube, Fast-SDD detector, digital signal processor and micro multichannel intelligent analysis module. Designed with 5 inch HD screen with clear display, 360° rotation and multi-points operation. No need for sample preparation, direct measurement and analysis of the surface of goods that need to tested.

  • Analytical Method Energy dispersive X-ray fluorescence analytical Method
    Elements Measuring Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
    Range Simultaneous detector
    Content measurement range ppm to 100%
    Detector SDD detector, Simultaneous analysis 40 elements
    Detector resolution Minimum can reach 128 eV
    Detection limit Minimum detection limits at 1 to 500 ppm
    Detection Objective Solid, liquid, powder Detection Objective Solid, liquid, powder
    The detection time 1 to 60 seconds (a second report results)
    Excitation source 50 kV/200 uA- silver target end window integrated miniature X ray tube and high voltage power supply
    Collimator and filter Collimator diameters are 4.0 mm and 2.0 mm, 6 kinds of filters with automatic switching functions
    Camera system Built-in 500 W pixels high definition camera, to observe testing position at any time
    Display screen Brand new 5 inch transflective LCD touch screen, the resolution is 1080×720
    Built-in system GPS, WIFI, Bluetooth
    Power Supply Rechargeable lithium battery, standard is 9000 mAh, sustainable work up to 12 hours
    Ambient temperature -20 to 50°C
    Relative Humidity ≤ 90%
    Data transmission Digital multi-channel technology, SPI data transmission, quick analysis, the high count rate; waterproof mini USB, and can be connected with a desktop computer
    Warning-Signalling System Green light means power on, red flushing means testing and yellow flushing means the problems
    Dimension (L×W×H) 244 × 90 × 330 mm
    Weight 1.7 kg
    • Energy dispersive X-ray fluorescence analytical Method
    • Simultaneous analysis of 40 elements using single detector
    • Digital multi-channel technology with SPI data transmission
    • Designed with 5 inch HD screen with clear display, 360° rotation, multi-points operation
    • Quick measurement and accurate testing of the samples for a long time by its test block
    • Rechargeable lithium battery 9000 mAh, sustainable work up to 12 hours
    • Integrated design of seal type with waterproof and dustproof function
    • Built in memory battery continue replace the battery power
    • Ergonomic, lightweight, handheld design, easy to carry, safe for transportation
    • Large data storage through ultra-high frequency memory and mass storage space
  • Handheld XRF Spectrometer is used for the exploration of elemental composition from magnesium (Mg) to uranium (U), from parts per million to 100%. Used across scientific centres, Research labs for quality testing of materials through measurement of elements present.

  • Accessories no.
    1Universal charger and car charger
    24G SD memory card and card reader
    3Two lithium battery and charger
    4PDA accessories
    5Radiation shield

XRF-Spectrometer LXRF-A10

  • S to UMeasureable elements
  • 1 ppmDetection limit
  • 15 ~ 30 °CTemperature
  • 1 ppm to 99 %Elemental content

Handheld XRF Spectrometer LXRF-B11

  • Energy dispersive X-ray fluorescence analytical MethodAnalytical Method
  • Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measuredElements Measuring
  • Simultaneous detectorRange
  • ppm to 99.99%Content measurement range

XRD Diffractometer LXRD-A10

  • Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kWX-ray Tuble
  • 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mmFocus Size
  • ≤ 0.01 %Stability
  • 5 to 80 mATube Current

Angular Spectrometer LASM-A10

  • 1inchAngle Measurement Accuracy
  • {"Focal Length":"170 mm","Effective Aperture":"\u03a6 22 mm","Field of View":"3\u00b0 22inch","Focal Length of Telescope\u2019s Eyepiece":"24.3 mm","Maximum Length Between Collimator and Telescope":"120 mm","Slit Width":"0.02 to 2 mm","Diopter Compensation Range":"\u2265 \u00b1 5 diopters"}Optical Parameter
  • {"Diameter":"\u03a6178 mm","Circle Graduation":"0\u00b0 to 360\u00b0","Division":"0.5\u00b0","Vernier Reading Value":"1inch"}Divided Circle
  • {"Diameter":"\u03a670 mm","Rotating Range":"360\u00b0","Range of Vertical Adjustment":"20 mm"}Stage
ICP Spectrometer LICP-A11
  • 180 to 900 nmWavelength range
  • 15 elementsElements per minute
  • 29 °CTemperature
  • 25 µmIncident slit
ICP spectrometer LICP-A10
  • 180 to 500 nmWavelength range ( 3600 lines / mm )
  • 180 to 800 nmWavelength range ( 2400 lines / mm )
  • 20 ~ 28 °CTemperature
  • 26 elementsElements per minute

ICP Spectrometer LICP-B10

  • {"Optical type":"Czerny turner","Resolution":"\u2264 0.015nm (3600 line grating) \u2264 0.030nm (2400 line grating)","Focal length":"1000 mm","Grating specifications":"huge holographic grating with 3600 L\/mil or 2400 L\/mil and 80 mm \u00d7 100 mm of ruling area","Wavelength range":"195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating"}Monochromator Specifications
  • {"Frequency":"27.12 MHz Frequency stability: < 0.05%","Spray chamber":"Scott double pass spray chamber","Output power":"800 W to 1600 W, adjustable with power efficiency more than 65%","Output power stability":"\u2264 0.05%","Induction coil":"25 mm \u00d7 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)"}Solid State Power Specifications
  • {"Suitable sample content range":"Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%","Repeatability":"short-term stability- RSD \u2264 1.5% Long-term stability: RSD \u2264 2%","Test speed":"5 to 8 elements \/ min","Limits of detection (LOD, \u00b5g\/L) for most elements":"1ppb to 10ppb"}Technical Specifications
  • {"Photomultiplier tube specification":"R212 \/ R928","Negative high voltage":"-50 to -1000 V","Circuit measuring range":"(10-12<\/sup> to 10 -4<\/sup>) A","Signal acquisition":"VF conversion"}Control Circuit

FTIR Spectrometer LIR-B10

  • 7800 cm-1 to 350 cm-1 Spectral Range
  • 0.85 cm-1 Resolution
  • ± 0.01 cm-1 Wave number precision
  • Microprocessor control, different scanning speed selectableScanning speed
Atomic Fluorescence Spectrometer LAFS-A10
  • Dual ChannelBeam Configuration
  • {"As, Se, Pb, Bi, Sb, Te, Sn":"< 0.01 \u00b5g\/L","Hg, Cd":"< 0.001 \u00b5g\/L","Zn":"< 1.0 \u00b5g\/L","Ge":"< 0.1 \u00b5g\/L"}Elements ( Measuring Range )
  • < 1.0Precision ( RSD )
  • More than 3 orders of magnitudeLinear range