Carton compression tester TP-I11

Carton compression tester TP-I11 with 100 mm/min return speed level measures the compressive strength of carton box. The compressor tester, adopted with ARM chip, powerful data functioning system, advanced sensor and automatic tracking system for test operations. The test results are recorded automatically, the real-time display is used to view the test data and is transferrable to computer.

  • Measuring range 1 to 50 kN
    Capacity
    Resolution
    Indication error < ± 1%
    Tearing arm
    Tearing angle
    Chips distance
    Clamp- paper
    Resection length
    Tearing distance
    Frictional resistance
    Pyramid dimension
    Platen Size 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)
    Operating stroke 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)
    Compression speed 10 mm/ min
    Impact angle
    Unit
    Error
    Sample amount
    Speed adjustment range 2 to 100 mm/ min
    Track & force speed in stacking test 2 mm/ min
    Test area
    Area differential pressure
    Inner diameter of grip ring
    Dimension
    Weight
    Power supply AC220 V ± 10 % , 50 Hz
    • Touch screen display
    • Customized design as per user’s need
    • Use of high precision pressure sensor for accurate measurement
    • Tests the maximal strength of box using ‘Strength test’
    • Data presetting to test the strength & variant of the carton box ‘Definite value test’
    • Stacking test is performed within 12 or 24 hours
    • Adopted with whorl and guide pillar for stability
  • Carton compression tester is used to determine compression strength & estimate stacking test of transport packages such as corrugated carton, paperboard box etc.

Vertical tensile tester TP-B20

  • 0 to 200 mm adjustableSample (size) length
  • 15 mmSample width
  • 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 NMeasuring range
  • ± 1 %Accuracy

Pulp beating (refining) freeness tester TP-C10

  • 0 to 100° SRMeasurement range
  • 100 ± 10 mm/sSealed testing speed
  • 1000 ± 5 mlVolume of distilled water
  • 149 ± 1 sDraining time

Paper and cardboard thickness meter TP-E20

  • 0 to 4 mmMeasuring range
  • 0.01 or 0.001 mmAccuracy
  • Analogue gauge displayGauge
  • 100 ± 10 kPaContact pressure (to create false weight)
Standard strip cutter TP-G10
  • 15 mmSample width
  • 300 mmSample maximum length
  • ≤ 0.1 mmParallelism
  • 240×520×70 mmDimension
Mullen burst tester TP-K10
  • 0 to 5600 kPaMeasurement range
  • ± 0.5 % F.S.Accuracy
  • 170 ± 15 ml/minCompression speed
  • ≥ 690 kPaClamp pressure

Whiteness meter TP-A11

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mmSystem
  • D65 as illuminating sourceLight source
  • ≤ 0.1 %Zero drift

Paper air permeability tester TP-J10

  • 0 to 1000 ml/minMeasuring range
  • 10 ± 0.02 cm2Test area
  • 1 ± 0.01 kPaArea differential pressure
  • 35.68 ± 0.05 mmInner diameter of grip ring

Tensile Stiffness Tester TP-B10

  • 38×70 mmSample (size) length
  • (1-500) mN.m (divided into 7 small ranges)Measuring range
  • 0.02Indication error
  • (200° ± 20°)/ minTest speed
Electronic bending stiffness tester TP-E10
  • 200° ± 20° / minTesting speed
  • 1 to 10000 mNTest range
  • ± 1 %Indicating Error
  • 5, 10, 15, 20, 25, 50 mmTesting length
Paper tearing tester TP-J20
  • 0 to 1000 mNMeasuring range
  • 0.1 mNResolution
  • ± 1 %Indication error
  • 104 ± 1 mmTearing arm

Crush tester TP-L10

  • 5 to 500 N, 50 to 3000 NMeasurement range
  • 1 NResolution
  • ± 1 %Accuracy
  • ≤ 1 %Variability

Water absorption tester TP-C20

  • 0 to 200 mmMeasurement range
  • 15×250 mmSpecimen size
  • 1 mmDivision value
  • 5Number of specimen holders

Paper and cardboard thickness meter TP-E21

  • 0 to 20 mmMeasuring range
  • 0.01 mmAccuracy
  • Analogue gauge displayGauge
  • 20 ± 0.5 kPaContact pressure (to create false weight)
COBB sample cutter TP-C30
  • 125 mmSample diameter
  • ± 0.2 mmSample error
  • 0.1 to 1.0 mmSample Thickness
  • 240×288×435 mmDimension
Internal Ply bond Tester TP-J11
  • A: 20 to 500 J/m2 B: 500 to 1000 J/m2Capacity
  • 90°Impact angle
  • Lb-ft/in2  J/m2Unit
  • A: ± 1 J/m2 B: ± 2 J/m2Error

Soil Salinity tester TSST-A10

  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy

Soil nutrient tester TSNA-A10

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Soil nutrient tester TSNA-A11
  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Benchtop gloss meter TBGM-A10
  • 60°Test angle
  • 2 × 3 mmGloss aperture
  • 0 to 1000 GUMeasurement range
  • 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)Repeatability

Whiteness and chromaticity tester TP-A10

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, bMeasurement mode
  • ≤ 0.1 within 30 minStability
  • Chromaticity co-ordinate 0.0001Accuracy

Whiteness meter TP-A11

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mmSystem
  • D65 as illuminating sourceLight source
  • ≤ 0.1 %Zero drift
Tensile Stiffness Tester TP-B10
  • 38×70 mmSample (size) length
  • (1-500) mN.m (divided into 7 small ranges)Measuring range
  • 0.02Indication error
  • (200° ± 20°)/ minTest speed
Three roll mill machine TRMM-A10
  • 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kgMixed capacity
  • RT to 300°CTemperature range
  • PID controlTemperature control system
  • LED displayDisplay

DIN abrasion tester TDAT-A10

  • 2.5 NTest arm weight
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,Additional Loads
  • 150 mmIdler
  • 40 ± 0.2 MAbrasion stroke

Rubber Low Temperature Brittleness Tester TRBT-A11

  • Room temperature to -70 ℃ (room temperature ≤ 25 ℃)Temperature control range
  • ± 0.3 ℃Temperature accuracy
  • 0℃ to -30℃ around 2.5 ℃/min
    -30℃ to -40℃ around 2.5 ℃/min
    -40℃ to -70℃ around 2.0 ℃/min
    Impact speed
  • 910 × 510 × 860 mmMax dimension L × W × H
Rockwell hardness meter TRHM-A11
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 1 to 30 STotal test force dwell time
  • Digital displayHardness indication
Rockwell hardness meter (motorized type) TRHM-B10
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 306, 613, 1839 NBrinell hardness test
  • 294, 588, 980 NVickers hardness test

Rockwell hardness meter TRHM-A10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 0 to 30 STotal test force dwell time
  • Analogue displayHardness indication