Carton compression tester TP-I11

Carton compression tester TP-I11 with 100 mm/min return speed level measures the compressive strength of carton box. The compressor tester, adopted with ARM chip, powerful data functioning system, advanced sensor and automatic tracking system for test operations. The test results are recorded automatically, the real-time display is used to view the test data and is transferrable to computer.

  • Measuring range 1 to 50 kN
    Capacity
    Resolution
    Indication error < ± 1%
    Tearing arm
    Tearing angle
    Chips distance
    Clamp- paper
    Resection length
    Tearing distance
    Frictional resistance
    Pyramid dimension
    Platen Size 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)
    Operating stroke 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)
    Compression speed 10 mm/ min
    Impact angle
    Unit
    Error
    Sample amount
    Speed adjustment range 2 to 100 mm/ min
    Track & force speed in stacking test 2 mm/ min
    Test area
    Area differential pressure
    Inner diameter of grip ring
    Dimension
    Weight
    Power supply AC220 V ± 10 % , 50 Hz
    • Touch screen display
    • Customized design as per user’s need
    • Use of high precision pressure sensor for accurate measurement
    • Tests the maximal strength of box using ‘Strength test’
    • Data presetting to test the strength & variant of the carton box ‘Definite value test’
    • Stacking test is performed within 12 or 24 hours
    • Adopted with whorl and guide pillar for stability
  • Carton compression tester is used to determine compression strength & estimate stacking test of transport packages such as corrugated carton, paperboard box etc.

Paper tearing tester TP-J20

  • 0 to 1000 mNMeasuring range
  • 0.1 mNResolution
  • ± 1 %Indication error
  • 104 ± 1 mmTearing arm

Water absorption tester- Cobb Tester TP-C21

  • (100 ± 0.2) cm2Metal Cylinder inner area
  • 50 mmMetal Cylinder height
  • (200 ± 0..5) mmMetal roller width
  • (10 ± 0.5) kgMetal roller weight

Puncture strength tester TP-J12

  • A (1 to 6) J indicating error ± 0.05 J
    B (1 to 12) J indicating error ± 0.05 J
    C (1 to 24) J indicating error ± 0.05 J
    D (1 to 48) J indicating error ± 0.05 J
    The indicating errors w.r.t measurement range of 20 to 80 %
    Measuring range
  • <0.25 JFrictional resistance
  • Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mmPyramid dimension
  • 800×470×840 mmDimension
Pulp beating (refining) freeness tester TP-C10
  • 0 to 100° SRMeasurement range
  • 100 ± 10 mm/sSealed testing speed
  • 1000 ± 5 mlVolume of distilled water
  • 149 ± 1 sDraining time
Vertical tensile tester TP-B20
  • 0 to 200 mm adjustableSample (size) length
  • 15 mmSample width
  • 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 NMeasuring range
  • ± 1 %Accuracy

Standard strip cutter TP-G10

  • 15 mmSample width
  • 300 mmSample maximum length
  • ≤ 0.1 mmParallelism
  • 240×520×70 mmDimension

Folding endurance tester TP-M10

  • 0 to 99999 sMeasuring scope
  • 135° ± 2°Folding angle
  • 4.9 to 14.7 NTensile scope
  • 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mmFolding head suture size

Water absorption tester TP-C20

  • 0 to 200 mmMeasurement range
  • 15×250 mmSpecimen size
  • 1 mmDivision value
  • 5Number of specimen holders
Crush tester TP-L10
  • 5 to 500 N, 50 to 3000 NMeasurement range
  • 1 NResolution
  • ± 1 %Accuracy
  • ≤ 1 %Variability
Ink rubber tester TP-F10
  • 230×50 mm (can join short samples together)Sample size (L*B)
  • 20 ± 0.2 NRub pressure
  • 43 times / minFriction speed
  • 155×50 mmFriction area (L*B)

Paper air permeability tester TP-J10

  • 0 to 1000 ml/minMeasuring range
  • 10 ± 0.02 cm2Test area
  • 1 ± 0.01 kPaArea differential pressure
  • 35.68 ± 0.05 mmInner diameter of grip ring

Mullen burst tester TP-K11

  • 0 to 1600 kPaMeasurement range
  • ± 0.5 % F.S.Accuracy
  • 95 ± 5 ml/minCompression speed
  • ≥ 430 kPaClamp pressure

Bekk Smoothness tester TP-L20

  • ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)Measuring scope
  • ±0.1 s within 300 sAccuracy
  • Bigger volume: 380 ± 1
    Smaller volume: 38 ± 1
    Vacuum system volume (ml)
  • 100 ± 2 kPaContact pressure
Coefficient of friction tester TP-D10
  • 0.01 to 10 NMeasurement range
  • 200 gSlider weight
  • 63×63 mmSlider size
  • ± 2 %Testing accuracy
Internal Ply bond Tester TP-J11
  • A: 20 to 500 J/m2 B: 500 to 1000 J/m2Capacity
  • 90°Impact angle
  • Lb-ft/in2  J/m2Unit
  • A: ± 1 J/m2 B: ± 2 J/m2Error

Rockwell hardness meter TRHM-A10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 0 to 30 STotal test force dwell time
  • Analogue displayHardness indication

Rockwell hardness meter (motorized type) TRHM-B10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 306, 613, 1839 NBrinell hardness test
  • 294, 588, 980 NVickers hardness test
Rockwell hardness meter TRHM-A11
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 1 to 30 STotal test force dwell time
  • Digital displayHardness indication
DIN abrasion tester TDAT-A10
  • 2.5 NTest arm weight
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,Additional Loads
  • 150 mmIdler
  • 40 ± 0.2 MAbrasion stroke

Rubber Low Temperature Brittleness Tester TRBT-A11

  • Room temperature to -70 ℃ (room temperature ≤ 25 ℃)Temperature control range
  • ± 0.3 ℃Temperature accuracy
  • 0℃ to -30℃ around 2.5 ℃/min
    -30℃ to -40℃ around 2.5 ℃/min
    -40℃ to -70℃ around 2.0 ℃/min
    Impact speed
  • 910 × 510 × 860 mmMax dimension L × W × H

Three roll mill machine TRMM-A10

  • 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kgMixed capacity
  • RT to 300°CTemperature range
  • PID controlTemperature control system
  • LED displayDisplay
Vacuum Leak Tester TVLT-A10
  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size
Oxygen Index Tester TOIT-A10
  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time

Aging Oven TAO-A10

  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable

Benchtop gloss meter TBGM-A10

  • 60°Test angle
  • 2 × 3 mmGloss aperture
  • 0 to 1000 GUMeasurement range
  • 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)Repeatability
Soil nutrient tester TSNA-A10
  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Soil nutrient tester TSNA-A11
  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error

Soil Salinity tester TSST-A10

  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy