Soil nutrient tester TSNA-A10

Soil nutrient tester TSNA-A10 with microprocessor controlled technology measures nutrient values in % and gives accurate test results. Its LCD touch display shows all test parameters, test results, which can be printed out using built-in printer. The optical filter present in the nutrient analyzer acts as light source, its silicon semiconductor acts as signal receiver system with 100000 hours of work life.

  • Measuring range 0.001 to 9999
    Stability A (absorbency of light) <0.003 within 3 mins
    Linearity error <3.0 %
    Repeatability error A (absorbency of light) <0.005
    Wavelength range Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm, Orange light: 590 ± 2 nm
    Sensitivity Red light: ≥ 4.5 × 10<sup>-5</sup> , Blue light: ≥ 3.17 × 10<sup>-3</sup> , Green light: ≥ 2.35 × 10<sup>-3</sup> , Orange light: ≥ 2.13 × 10<sup>-3</sup>
    Moisture measure range A: humidity 0 to 100 %, B: Accuracy: ±3 %
    Measurement time (for soil N, P, K) ≤30 min<br/> 5 pcs soil samples at one time ≤50 min (including pretreatment time)
    Soil moisture mode
    • Moisture content rate testing range: 0 to 100 %
    • Moisture unit: % (m<sup>3</sup>/m<sup>3</sup>)
    • Accuracy: ± 2 %
    pH mode
    • pH Measurement range: 1 to 14 pH
    • pH Accuracy: ± 0.1
    Conductivity mode
    • Conductivity Measurement range: 0.01 % to 1.00 %
    • Conductivity Accuracy: ± 5 %
    Dimension 340 × 280 × 100 mm
    Gross Weight 15 kg
    Power supply AC 180 to 240 V, 50 Hz
    • LCD display touch control
    • Microprocessor controlled technology
    • Built-in thermal printer
    • Automatic temperature calibration system for organic phosphorous testing
    • Excellent shock resistant
    • Digital circuit programmed design
  • It finds best application in quantitative analysis of to N, P, K, organic matter, pH, trace elements, salinity of soil, fertilizer & other samples.

  • Reagent as per requirement/need

Soil moisture meter TSMM-A10

  • 0 to 80 %Measurement range
  • 0.1Resolution
  • ± 2 % n (non-saturation condition)Accuracy
  • 280 mmNeedle

Soil Water potential tester TSWT-A10

  • 0 to 100 kPaMeasuring range
  • 0.01 kPaResolution
  • ± 1 kPaAccuracy
  • -55 to 105°CSoil temperature measuring range

Soil water hardness meter TSHM-A11

  • 100 kg ( kg and N can be switched automatically)Maximum load
  • 0.01 gResolution
  • ± 0.5 %Accuracy
  • 0 to 450 mmMeasuring depth
Soil Salinity tester TSST-A10
  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy
Soil moisture meter TSMM-A12
  • 0 to 60 %Measurement range
  • 0.1Resolution
  • ± 5 % n (non-saturation condition)Accuracy
  • 280 mmNeedle

Soil moisture meter TSMM-A11

  • 0 to 90 %Measurement range
  • 0.1 or 0.01Resolution
  • ± 5 % n (non-saturation condition)Accuracy
  • 235 mmNeedle

Soil water hardness meter TSHM-A10

  • 100 kg ( kg and N can be switched automatically)Maximum load
  • 0.01 gResolution
  • ± 0.5 %Accuracy
  • 0 to 40 mmMeasuring depth

Soil nutrient tester TSNA-A11

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error

Rockwell hardness meter TRHM-A10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 0 to 30 STotal test force dwell time
  • Analogue displayHardness indication

Rockwell hardness meter TRHM-A11

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 1 to 30 STotal test force dwell time
  • Digital displayHardness indication
Rockwell hardness meter (motorized type) TRHM-B10
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 306, 613, 1839 NBrinell hardness test
  • 294, 588, 980 NVickers hardness test
Benchtop gloss meter TBGM-A10
  • 60°Test angle
  • 2 × 3 mmGloss aperture
  • 0 to 1000 GUMeasurement range
  • 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)Repeatability

Soil nutrient tester TSNA-A10

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error

Soil nutrient tester TSNA-A11

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Soil Salinity tester TSST-A10
  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy
Oxygen Index Tester TOIT-A10
  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time

Aging Oven TAO-A10

  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable

Vacuum Leak Tester TVLT-A10

  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size
Whiteness meter TP-A11
  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mmSystem
  • D65 as illuminating sourceLight source
  • ≤ 0.1 %Zero drift
Tensile Stiffness Tester TP-B10
  • 38×70 mmSample (size) length
  • (1-500) mN.m (divided into 7 small ranges)Measuring range
  • 0.02Indication error
  • (200° ± 20°)/ minTest speed

Whiteness and chromaticity tester TP-A10

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, bMeasurement mode
  • ≤ 0.1 within 30 minStability
  • Chromaticity co-ordinate 0.0001Accuracy