DIN abrasion tester TDAT-A10

DIN abrasion tester TDAT-A10 determines abrasion resistance of rubber made products, natural rubber, vulcanized rubber, thermoplastic amorphous polymers to withstand the long term damage as a result of friction due to its excessive use. The ratio between standard loss of rubber material & test rubber material, expressed in percentage, marks the abrasion resistance index of sample under test.

  • Test arm weight 2.5 N
    Additional Loads 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
    Idler 150 mm
    Abrasion stroke 40 ± 0.2 M
    Horizontal displacement 4.2 mm/ rotation
    Stroke 20 m/ 40 m presetting
    Grips lateral displacement 4.2 ± 0.04 mm/ rotation
    Idler wheel speed 40 ± 1 rpm
    Measurement mode Auto/ manual presetting
    Specimen size Diameter 16 mm, thickness at least 6 mm
    Emery cloth specifications 60 # seam is less than 2 mm
    Shift screw 6 teeth/ inch
    Limit rotation 85 rotate
    Set rotation 84 rotation of 40 meters
    Return form Electric automatic reset
    Net Weight 75 kg
    Dimension 950 × 660 × 310 mm
    Control temperature range
    Temperature tester
    Temperature display resolution
    Temperature control accuracy
    Calibration accuracy
    Rotor speed
    Die cavity frequency
    Sway angle
    Air compression
    Ambient temperature
    Test result
    Display
    Speed accuracy
    Torque range
    Torque resolution
    Printer connection
    Content printed
    Product dimension
    Weight
    Power supply 220 V, 50 / 60Hz
    • Automatic electric lock for the rotating cylinder
    • Mechanical unlocking of the cylinder for easy abrasive replacement
    • Screw for adjustment of abrasion specimen
    • Enables control uniformity of specific material
    • Machine with metallic base plate, polished paint & zinc coating
    • High quality machine design with reproducible results
    • Easy to operate
  • DIN abrasion tester is used to determine the abrasion resistance of elastomers by the frictional loss of the rubber in products such as tires, conveyor belts, hoses, footwear, floor covering, thermoplastic amorphous polymers etc.

Rubber-weiss plasticity testing machine TRWM-A10

  • RT 50° to 300°Temperature range
  • ± 1°Temperature accuracy
  • 0.01 to 25 mmMeasuring range
  • ± 0.01 mmAccuracy

No rotor rheometer TNRR-A10

  • Room temperature to 200°CTemperature tester
  • 0.1°CTemperature display resolution
  • ≤ ± 0.3°CTemperature control accuracy
  • 100 times/ minRotor speed

Rubber Low Temperature Brittleness Tester TRBT-A11

  • Room temperature to -70 ℃ (room temperature ≤ 25 ℃)Temperature control range
  • ± 0.3 ℃Temperature accuracy
  • 0℃ to -30℃ around 2.5 ℃/min
    -30℃ to -40℃ around 2.5 ℃/min
    -40℃ to -70℃ around 2.0 ℃/min
    Impact speed
  • 910 × 510 × 860 mmMax dimension L × W × H
Rubber low temperature brittleness tester TRBT-A10
  • -60°C to 0°CTemperature range
  • ± 0.5°CTemperature accuracy
  • 2 m/s ± 0.2 m/sImpact speed
  • <± 0.5°CTemperature fluctuation
Three roll mill machine TRMM-A10
  • 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kgMixed capacity
  • RT to 300°CTemperature range
  • PID controlTemperature control system
  • LED displayDisplay

Mooney viscometer TMV-A10

  • Normal temperature to 200°CControl temperature range
  • 0.01°CTemperature display resolution
  • ± 0.3°Temperature control accuracy
  • Mooney value ± 0.5Calibration accuracy

Rockwell hardness meter TRHM-A11

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 1 to 30 STotal test force dwell time
  • Digital displayHardness indication

Rockwell hardness meter TRHM-A10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 0 to 30 STotal test force dwell time
  • Analogue displayHardness indication
Rockwell hardness meter (motorized type) TRHM-B10
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 306, 613, 1839 NBrinell hardness test
  • 294, 588, 980 NVickers hardness test
Oxygen Index Tester TOIT-A10
  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time

Vacuum Leak Tester TVLT-A10

  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size

Aging Oven TAO-A10

  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable
Benchtop gloss meter TBGM-A10
  • 60°Test angle
  • 2 × 3 mmGloss aperture
  • 0 to 1000 GUMeasurement range
  • 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)Repeatability
Tensile Stiffness Tester TP-B10
  • 38×70 mmSample (size) length
  • (1-500) mN.m (divided into 7 small ranges)Measuring range
  • 0.02Indication error
  • (200° ± 20°)/ minTest speed

Whiteness and chromaticity tester TP-A10

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, bMeasurement mode
  • ≤ 0.1 within 30 minStability
  • Chromaticity co-ordinate 0.0001Accuracy

Whiteness meter TP-A11

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mmSystem
  • D65 as illuminating sourceLight source
  • ≤ 0.1 %Zero drift
DIN abrasion tester TDAT-A10
  • 2.5 NTest arm weight
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,Additional Loads
  • 150 mmIdler
  • 40 ± 0.2 MAbrasion stroke
Rubber Low Temperature Brittleness Tester TRBT-A11
  • Room temperature to -70 ℃ (room temperature ≤ 25 ℃)Temperature control range
  • ± 0.3 ℃Temperature accuracy
  • 0℃ to -30℃ around 2.5 ℃/min
    -30℃ to -40℃ around 2.5 ℃/min
    -40℃ to -70℃ around 2.0 ℃/min
    Impact speed
  • 910 × 510 × 860 mmMax dimension L × W × H

Three roll mill machine TRMM-A10

  • 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kgMixed capacity
  • RT to 300°CTemperature range
  • PID controlTemperature control system
  • LED displayDisplay