No rotor rheometer TNRR-A10

TNRR-A10 is a No rotor rheometer where rubber sample is enclosed in mold cavity, maintained at test temperature. The mold cavity comes in two parts, where lower part (swing oscillations) determines strain as the reaction torque of the mold cavity (force). The PID controlled microprocessor technology controls and detects change in temperature. LCD screen display the real vulcanization curve and temperature curve, adjust the test data, store test results.

  • Test arm weight
    Additional Loads
    Idler
    Abrasion stroke
    Horizontal displacement
    Stroke
    Grips lateral displacement
    Idler wheel speed
    Measurement mode
    Specimen size
    Emery cloth specifications
    Shift screw
    Limit rotation
    Set rotation
    Return form
    Net Weight
    Dimension
    Control temperature range
    Temperature tester Room temperature to 200°C
    Temperature display resolution 0.1°C
    Temperature control accuracy ≤ ± 0.3°C
    Calibration accuracy
    Rotor speed 100 times/ min
    Die cavity frequency 1.7 Hz
    Sway angle ± 0.5°, ± 1°, ± 3°
    Air compression 0.5 MPa to 0.65 MPa
    Ambient temperature 0 to 35°C
    Test result Printed date, time, temperature, vulcanization curve, temperature curve ML, MH, ts1, ts2, t10, t50, Vc1, Vc2
    Display Windows 7 + software
    Speed accuracy
    Torque range 0 to 5 NM, 0 to 10 NM, 0 to 20 NM
    Torque resolution 0.001 NM
    Printer connection
    Content printed
    Product dimension 1310 × 560 × 620 mm
    Weight 250 kg
    Power supply Single phase, 220 V ± 10%, 50 Hz
    • PID controlled microprocessor technology
    • LCD Display
    • Use of highly imported precision sensors
    • Statistics, analysis, storage and comparison functions
    • Can print automatic processing, calculations results
    • Non curing viscometer monolithic rotor controlled
    • User-friendly design appearance, easy to operate
    • Supplied with data acquisition system
    • Finds the vulcanization time for gelatin
  • No rotor rheometer is used to test vulcanization characteristics of rubber material across rubber industry for quality & research.

Three roll mill machine TRMM-A10

  • 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kgMixed capacity
  • RT to 300°CTemperature range
  • PID controlTemperature control system
  • LED displayDisplay

Rubber-weiss plasticity testing machine TRWM-A10

  • RT 50° to 300°Temperature range
  • ± 1°Temperature accuracy
  • 0.01 to 25 mmMeasuring range
  • ± 0.01 mmAccuracy

Rubber Low Temperature Brittleness Tester TRBT-A11

  • Room temperature to -70 ℃ (room temperature ≤ 25 ℃)Temperature control range
  • ± 0.3 ℃Temperature accuracy
  • 0℃ to -30℃ around 2.5 ℃/min
    -30℃ to -40℃ around 2.5 ℃/min
    -40℃ to -70℃ around 2.0 ℃/min
    Impact speed
  • 910 × 510 × 860 mmMax dimension L × W × H
Rubber low temperature brittleness tester TRBT-A10
  • -60°C to 0°CTemperature range
  • ± 0.5°CTemperature accuracy
  • 2 m/s ± 0.2 m/sImpact speed
  • <± 0.5°CTemperature fluctuation
DIN abrasion tester TDAT-A10
  • 2.5 NTest arm weight
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,Additional Loads
  • 150 mmIdler
  • 40 ± 0.2 MAbrasion stroke

Mooney viscometer TMV-A10

  • Normal temperature to 200°CControl temperature range
  • 0.01°CTemperature display resolution
  • ± 0.3°Temperature control accuracy
  • Mooney value ± 0.5Calibration accuracy

Three roll mill machine TRMM-A10

  • 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kgMixed capacity
  • RT to 300°CTemperature range
  • PID controlTemperature control system
  • LED displayDisplay

DIN abrasion tester TDAT-A10

  • 2.5 NTest arm weight
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,Additional Loads
  • 150 mmIdler
  • 40 ± 0.2 MAbrasion stroke
Rubber Low Temperature Brittleness Tester TRBT-A11
  • Room temperature to -70 ℃ (room temperature ≤ 25 ℃)Temperature control range
  • ± 0.3 ℃Temperature accuracy
  • 0℃ to -30℃ around 2.5 ℃/min
    -30℃ to -40℃ around 2.5 ℃/min
    -40℃ to -70℃ around 2.0 ℃/min
    Impact speed
  • 910 × 510 × 860 mmMax dimension L × W × H
Rockwell hardness meter (motorized type) TRHM-B10
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 306, 613, 1839 NBrinell hardness test
  • 294, 588, 980 NVickers hardness test

Rockwell hardness meter TRHM-A11

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 1 to 30 STotal test force dwell time
  • Digital displayHardness indication

Rockwell hardness meter TRHM-A10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 0 to 30 STotal test force dwell time
  • Analogue displayHardness indication
Whiteness meter TP-A11
  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mmSystem
  • D65 as illuminating sourceLight source
  • ≤ 0.1 %Zero drift
Tensile Stiffness Tester TP-B10
  • 38×70 mmSample (size) length
  • (1-500) mN.m (divided into 7 small ranges)Measuring range
  • 0.02Indication error
  • (200° ± 20°)/ minTest speed

Whiteness and chromaticity tester TP-A10

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, bMeasurement mode
  • ≤ 0.1 within 30 minStability
  • Chromaticity co-ordinate 0.0001Accuracy

Soil nutrient tester TSNA-A11

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Soil nutrient tester TSNA-A10
  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Soil Salinity tester TSST-A10
  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy

Vacuum Leak Tester TVLT-A10

  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size

Oxygen Index Tester TOIT-A10

  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time
Aging Oven TAO-A10
  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable