Soil moisture meter TSMM-A12

Soil moisture meter TSMM-A12 with compact, portable design finds application in moisture measurement of soil & cement, sand, powders. Equipped with LCD display, this soil moisture meter saves time, the cost incurred in by monitoring dryness of the soil & helps to prevent deterioration occurring from moisture during its storage. This moisture meter goes automatically off after 5 minutes of last operation, also it can be switched off manually.

  • Measurement range 0 to 60 %
    Resolution 0.1
    Accuracy ± 5 % n (non-saturation condition)
    Needle 280 mm
    Display Digital LCD 1.69×1.04 inches
    Temperature range 0 to 60°C
    Humidity range 5 to 90 % RH
    Battery dimension 140 × 60 × 22 mm
    Net weight 210 g (excluding batteries)
    Gross weight 700 g
    Power supply 4 1.5 AAA size (UM4 )
    • Portable nature
    • Back light digital LCD display
    • Automatic temperature compensation
    • Instant moisture measurement readings
    • Alarm alert for low battery level
    • Auto power off function
    • Data hold function
    • User-friendly appearance
    • Easy to use
  • Used for best applications in research & development, agriculture, horticulture, construction & other industry to measure moisture of soil, cement, sand, powders.

Soil water hardness meter TSHM-A11

  • 100 kg ( kg and N can be switched automatically)Maximum load
  • 0.01 gResolution
  • ± 0.5 %Accuracy
  • 0 to 450 mmMeasuring depth

Soil water hardness meter TSHM-A10

  • 100 kg ( kg and N can be switched automatically)Maximum load
  • 0.01 gResolution
  • ± 0.5 %Accuracy
  • 0 to 40 mmMeasuring depth

Soil nutrient tester TSNA-A10

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Soil nutrient tester TSNA-A11
  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Soil Salinity tester TSST-A10
  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy

Soil moisture meter TSMM-A10

  • 0 to 80 %Measurement range
  • 0.1Resolution
  • ± 2 % n (non-saturation condition)Accuracy
  • 280 mmNeedle

Soil Water potential tester TSWT-A10

  • 0 to 100 kPaMeasuring range
  • 0.01 kPaResolution
  • ± 1 kPaAccuracy
  • -55 to 105°CSoil temperature measuring range

Soil moisture meter TSMM-A11

  • 0 to 90 %Measurement range
  • 0.1 or 0.01Resolution
  • ± 5 % n (non-saturation condition)Accuracy
  • 235 mmNeedle

Soil nutrient tester TSNA-A10

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error

Soil Salinity tester TSST-A10

  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy
Soil nutrient tester TSNA-A11
  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Rockwell hardness meter TRHM-A11
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 1 to 30 STotal test force dwell time
  • Digital displayHardness indication

Rockwell hardness meter (motorized type) TRHM-B10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 306, 613, 1839 NBrinell hardness test
  • 294, 588, 980 NVickers hardness test

Rockwell hardness meter TRHM-A10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 0 to 30 STotal test force dwell time
  • Analogue displayHardness indication
Oxygen Index Tester TOIT-A10
  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time
Aging Oven TAO-A10
  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable

Vacuum Leak Tester TVLT-A10

  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size

Benchtop gloss meter TBGM-A10

  • 60°Test angle
  • 2 × 3 mmGloss aperture
  • 0 to 1000 GUMeasurement range
  • 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)Repeatability
DIN abrasion tester TDAT-A10
  • 2.5 NTest arm weight
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,Additional Loads
  • 150 mmIdler
  • 40 ± 0.2 MAbrasion stroke
Rubber Low Temperature Brittleness Tester TRBT-A11
  • Room temperature to -70 ℃ (room temperature ≤ 25 ℃)Temperature control range
  • ± 0.3 ℃Temperature accuracy
  • 0℃ to -30℃ around 2.5 ℃/min
    -30℃ to -40℃ around 2.5 ℃/min
    -40℃ to -70℃ around 2.0 ℃/min
    Impact speed
  • 910 × 510 × 860 mmMax dimension L × W × H

Three roll mill machine TRMM-A10

  • 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kgMixed capacity
  • RT to 300°CTemperature range
  • PID controlTemperature control system
  • LED displayDisplay