Soil water hardness meter TSHM-A10

Soil water hardness meter TSHM-A10 comes in handheld design is adopted with theoretical value pressure gauge kg/cm2 to directly measure the soil hardness. Hardness meter used in soil property survey, for testing soil permeability and aeration. Provides accurate reliable results.

  • Maximum load 100 kg ( kg and N can be switched automatically)
    Resolution 0.01 g
    Accuracy ± 0.5 %
    Measuring depth 0 to 40 mm
    Hardness indication range 0 to 500 kg/ cm<sup>2</sup>
    Environmental temperature 0 to 60°C
    Allowable overload 1.5
    Memory storage
    Power supply mode 5 Nickel Cyanogen
    Battery capacity Continuous operated battery, 6 to 8 hrs
    Gross weight 2 kg
    Power supply Chargeable AC 100 to 240 voltage
    • Analog display
    • Easy to clean probe
    • Durable pin pointer for measurement
    • Manual adjustment for zero value
  • Used for soil water hardness measurement of dry to normal & moist soil for quality analysis & testing purpose.

Soil nutrient tester TSNA-A10

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error

Soil moisture meter TSMM-A12

  • 0 to 60 %Measurement range
  • 0.1Resolution
  • ± 5 % n (non-saturation condition)Accuracy
  • 280 mmNeedle

Soil water hardness meter TSHM-A11

  • 100 kg ( kg and N can be switched automatically)Maximum load
  • 0.01 gResolution
  • ± 0.5 %Accuracy
  • 0 to 450 mmMeasuring depth
Soil moisture meter TSMM-A10
  • 0 to 80 %Measurement range
  • 0.1Resolution
  • ± 2 % n (non-saturation condition)Accuracy
  • 280 mmNeedle
Soil nutrient tester TSNA-A11
  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error

Soil Water potential tester TSWT-A10

  • 0 to 100 kPaMeasuring range
  • 0.01 kPaResolution
  • ± 1 kPaAccuracy
  • -55 to 105°CSoil temperature measuring range

Soil Salinity tester TSST-A10

  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy

Soil moisture meter TSMM-A11

  • 0 to 90 %Measurement range
  • 0.1 or 0.01Resolution
  • ± 5 % n (non-saturation condition)Accuracy
  • 235 mmNeedle

Soil Salinity tester TSST-A10

  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy

Soil nutrient tester TSNA-A11

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Soil nutrient tester TSNA-A10
  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Vacuum Leak Tester TVLT-A10
  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size

Aging Oven TAO-A10

  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable

Oxygen Index Tester TOIT-A10

  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time
Benchtop gloss meter TBGM-A10
  • 60°Test angle
  • 2 × 3 mmGloss aperture
  • 0 to 1000 GUMeasurement range
  • 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)Repeatability
Three roll mill machine TRMM-A10
  • 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kgMixed capacity
  • RT to 300°CTemperature range
  • PID controlTemperature control system
  • LED displayDisplay

DIN abrasion tester TDAT-A10

  • 2.5 NTest arm weight
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,Additional Loads
  • 150 mmIdler
  • 40 ± 0.2 MAbrasion stroke

Rubber Low Temperature Brittleness Tester TRBT-A11

  • Room temperature to -70 ℃ (room temperature ≤ 25 ℃)Temperature control range
  • ± 0.3 ℃Temperature accuracy
  • 0℃ to -30℃ around 2.5 ℃/min
    -30℃ to -40℃ around 2.5 ℃/min
    -40℃ to -70℃ around 2.0 ℃/min
    Impact speed
  • 910 × 510 × 860 mmMax dimension L × W × H
Rockwell hardness meter TRHM-A11
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 1 to 30 STotal test force dwell time
  • Digital displayHardness indication
Rockwell hardness meter TRHM-A10
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 0 to 30 STotal test force dwell time
  • Analogue displayHardness indication

Rockwell hardness meter (motorized type) TRHM-B10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 306, 613, 1839 NBrinell hardness test
  • 294, 588, 980 NVickers hardness test