Soil water hardness meter TSHM-A10

Soil water hardness meter TSHM-A10 comes in handheld design is adopted with theoretical value pressure gauge kg/cm2 to directly measure the soil hardness. Hardness meter used in soil property survey, for testing soil permeability and aeration. Provides accurate reliable results.

  • Maximum load 100 kg ( kg and N can be switched automatically)
    Resolution 0.01 g
    Accuracy ± 0.5 %
    Measuring depth 0 to 40 mm
    Hardness indication range 0 to 500 kg/ cm<sup>2</sup>
    Environmental temperature 0 to 60°C
    Allowable overload 1.5
    Memory storage
    Power supply mode 5 Nickel Cyanogen
    Battery capacity Continuous operated battery, 6 to 8 hrs
    Gross weight 2 kg
    Power supply Chargeable AC 100 to 240 voltage
    • Analog display
    • Easy to clean probe
    • Durable pin pointer for measurement
    • Manual adjustment for zero value
  • Used for soil water hardness measurement of dry to normal & moist soil for quality analysis & testing purpose.

Soil nutrient tester TSNA-A11

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error

Soil moisture meter TSMM-A12

  • 0 to 60 %Measurement range
  • 0.1Resolution
  • ± 5 % n (non-saturation condition)Accuracy
  • 280 mmNeedle

Soil nutrient tester TSNA-A10

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Soil moisture meter TSMM-A10
  • 0 to 80 %Measurement range
  • 0.1Resolution
  • ± 2 % n (non-saturation condition)Accuracy
  • 280 mmNeedle
Soil Water potential tester TSWT-A10
  • 0 to 100 kPaMeasuring range
  • 0.01 kPaResolution
  • ± 1 kPaAccuracy
  • -55 to 105°CSoil temperature measuring range

Soil water hardness meter TSHM-A11

  • 100 kg ( kg and N can be switched automatically)Maximum load
  • 0.01 gResolution
  • ± 0.5 %Accuracy
  • 0 to 450 mmMeasuring depth

Soil moisture meter TSMM-A11

  • 0 to 90 %Measurement range
  • 0.1 or 0.01Resolution
  • ± 5 % n (non-saturation condition)Accuracy
  • 235 mmNeedle

Soil Salinity tester TSST-A10

  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy

Benchtop gloss meter TBGM-A10

  • 60°Test angle
  • 2 × 3 mmGloss aperture
  • 0 to 1000 GUMeasurement range
  • 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)Repeatability

Whiteness meter TP-A11

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mmSystem
  • D65 as illuminating sourceLight source
  • ≤ 0.1 %Zero drift
Tensile Stiffness Tester TP-B10
  • 38×70 mmSample (size) length
  • (1-500) mN.m (divided into 7 small ranges)Measuring range
  • 0.02Indication error
  • (200° ± 20°)/ minTest speed
Whiteness and chromaticity tester TP-A10
  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, bMeasurement mode
  • ≤ 0.1 within 30 minStability
  • Chromaticity co-ordinate 0.0001Accuracy

Vacuum Leak Tester TVLT-A10

  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size

Aging Oven TAO-A10

  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable
Oxygen Index Tester TOIT-A10
  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time
Soil nutrient tester TSNA-A11
  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error

Soil Salinity tester TSST-A10

  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy

Soil nutrient tester TSNA-A10

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Rockwell hardness meter TRHM-A10
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 0 to 30 STotal test force dwell time
  • Analogue displayHardness indication
Rockwell hardness meter (motorized type) TRHM-B10
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 306, 613, 1839 NBrinell hardness test
  • 294, 588, 980 NVickers hardness test

Rockwell hardness meter TRHM-A11

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 1 to 30 STotal test force dwell time
  • Digital displayHardness indication