Crush tester TP-L10

Crush tester TP-L10 is adopted with advanced parts, microprocessor controlled system and multifunctional design to test, translate, adjust, display, remember, and print the test data. User can conduct any test of choice like TCT, FCT, ECT, and PAT for paper and cardboard material by selecting additional, corresponding accessories.

  • Measurement range 5 to 500 N, 50 to 3000 N
    Measuring scope
    Folding angle
    Tensile scope
    Folding head suture size
    Folding radius
    Resolution 1 N
    Accuracy ± 1 %
    Variability ≤ 1 %
    Speed 12.5 ± 2.5 mm/min
    Vacuum system volume (ml)
    Contact pressure
    Vacuum scope
    Air volume (50.66 kPa down to 48.00 kPa)
    Maximum distance 78 mm
    Compression speed
    Clamp pressure
    Diameter of upper clamp
    Diameter of lower clamp
    Pneumatic pressure
    Film resistance
    Dimension 450×400×500 mm
    Net weight 75 kg
    Power supply AC220 V ± 10 % , 50 Hz
    • Compact structure
    • Easy maintenance
    • Tests peel strength (PAT) using peel test rack
    • Tests Strength of flat compression (FCT) using flat compression sampler
    • Tests edge crush test (ECT) using edge crush cutter and auxiliary guide block
    • Tests ring crush test (RCT) using compression plate and special sampler
  • The crush tester is used to test crush strength of paper & paperboard using different auxiliary appliances across paper & printing, packaging industry.

Whiteness meter TP-A11

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mmSystem
  • D65 as illuminating sourceLight source
  • ≤ 0.1 %Zero drift

Mullen burst tester TP-K10

  • 0 to 5600 kPaMeasurement range
  • ± 0.5 % F.S.Accuracy
  • 170 ± 15 ml/minCompression speed
  • ≥ 690 kPaClamp pressure

Softness tester TP-H10

  • 10 to 1000 mNMeasuring range
  • 1 mNDivision value
  • ± 1%Accuracy
  • ≤ 0.5Indicating Error
Bekk Smoothness tester TP-L20
  • ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)Measuring scope
  • ±0.1 s within 300 sAccuracy
  • Bigger volume: 380 ± 1
    Smaller volume: 38 ± 1
    Vacuum system volume (ml)
  • 100 ± 2 kPaContact pressure
Electronic bending stiffness tester TP-E10
  • 200° ± 20° / minTesting speed
  • 1 to 10000 mNTest range
  • ± 1 %Indicating Error
  • 5, 10, 15, 20, 25, 50 mmTesting length

Whiteness and chromaticity tester TP-A10

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, bMeasurement mode
  • ≤ 0.1 within 30 minStability
  • Chromaticity co-ordinate 0.0001Accuracy

Standard strip cutter TP-G10

  • 15 mmSample width
  • 300 mmSample maximum length
  • ≤ 0.1 mmParallelism
  • 240×520×70 mmDimension

Vertical tensile tester TP-B20

  • 0 to 200 mm adjustableSample (size) length
  • 15 mmSample width
  • 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 NMeasuring range
  • ± 1 %Accuracy
Internal Ply bond Tester TP-J11
  • A: 20 to 500 J/m2 B: 500 to 1000 J/m2Capacity
  • 90°Impact angle
  • Lb-ft/in2  J/m2Unit
  • A: ± 1 J/m2 B: ± 2 J/m2Error
COBB sample cutter TP-C30
  • 125 mmSample diameter
  • ± 0.2 mmSample error
  • 0.1 to 1.0 mmSample Thickness
  • 240×288×435 mmDimension

Puncture strength tester TP-J12

  • A (1 to 6) J indicating error ± 0.05 J
    B (1 to 12) J indicating error ± 0.05 J
    C (1 to 24) J indicating error ± 0.05 J
    D (1 to 48) J indicating error ± 0.05 J
    The indicating errors w.r.t measurement range of 20 to 80 %
    Measuring range
  • <0.25 JFrictional resistance
  • Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mmPyramid dimension
  • 800×470×840 mmDimension

Folding endurance tester TP-M10

  • 0 to 99999 sMeasuring scope
  • 135° ± 2°Folding angle
  • 4.9 to 14.7 NTensile scope
  • 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mmFolding head suture size

Automatic horizontal tensile tester TP-B11

  • 90 to 200 mmSample (size) length
  • 15 mm, 25 mm, 50mmSample width
  • 0 to 30, 0 to 100 N,0 to 300 NMeasuring range
  • ± 1 %Accuracy
Electronic Tearing tester TP-J21
  • 10 -16000 mNCapacity
  • 0.1 mNResolution
  • 104 ± 1 mmTearing arm
  • 27.5° ± 5°Tearing angle
Carton compression tester TP-I11
  • 1 to 50 kNMeasuring range
  • < ± 1%Indication error
  • 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)Platen Size
  • 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)Operating stroke

Benchtop gloss meter TBGM-A10

  • 60°Test angle
  • 2 × 3 mmGloss aperture
  • 0 to 1000 GUMeasurement range
  • 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)Repeatability

Oxygen Index Tester TOIT-A10

  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time
Vacuum Leak Tester TVLT-A10
  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size
Aging Oven TAO-A10
  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable

Soil nutrient tester TSNA-A11

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error

Soil Salinity tester TSST-A10

  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy
Soil nutrient tester TSNA-A10
  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Whiteness and chromaticity tester TP-A10
  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, bMeasurement mode
  • ≤ 0.1 within 30 minStability
  • Chromaticity co-ordinate 0.0001Accuracy

Whiteness meter TP-A11

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mmSystem
  • D65 as illuminating sourceLight source
  • ≤ 0.1 %Zero drift

Tensile Stiffness Tester TP-B10

  • 38×70 mmSample (size) length
  • (1-500) mN.m (divided into 7 small ranges)Measuring range
  • 0.02Indication error
  • (200° ± 20°)/ minTest speed
Rockwell hardness meter TRHM-A11
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 1 to 30 STotal test force dwell time
  • Digital displayHardness indication
Rockwell hardness meter TRHM-A10
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 0 to 30 STotal test force dwell time
  • Analogue displayHardness indication

Rockwell hardness meter (motorized type) TRHM-B10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 306, 613, 1839 NBrinell hardness test
  • 294, 588, 980 NVickers hardness test