Folding endurance tester TP-M10

Folding endurance tester TP-M10 is used to measure the folding endurance of paper, cardboard and other paper like sheet, material. The folding clamp can be positioned automatically. The microprocessor controlled technology, complete functions, stable performance, easy to use parameters are the advantages of this instrument.

  • Measurement range
    Measuring scope 0 to 99999 s
    Folding angle 135° ± 2°
    Tensile scope 4.9 to 14.7 N
    Folding head suture size 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm
    Folding radius 0.38 ± 0.02 mm
    Resolution
    Accuracy
    Variability
    Speed
    Vacuum system volume (ml)
    Contact pressure
    Vacuum scope
    Air volume (50.66 kPa down to 48.00 kPa)
    Maximum distance
    Compression speed
    Clamp pressure
    Diameter of upper clamp
    Diameter of lower clamp
    Pneumatic pressure
    Film resistance
    Dimension 320×320×450 mm
    Net weight 35 kg
    Power supply AC220 V ± 10 % , 50 Hz
    • Touch screen display
    • Automatic measurements, statistic values
    • Automatic return to zero once the test gets completed
    • Can print the test results
    • Data storage function
    • Electromechanical integration of modern design
    • Easy operations, safe & reliable results
  • Folding endurance tester has applications in paper industry, cardboard, packaging industry.

Automatic horizontal tensile tester TP-B12

  • 180 mm (180, 150, 100, 90, 50 mm adjustable)Sample (size) length
  • 15 mmSample width
  • 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 NMeasuring range
  • ± 1 %Accuracy

Internal Ply bond Tester TP-J11

  • A: 20 to 500 J/m2 B: 500 to 1000 J/m2Capacity
  • 90°Impact angle
  • Lb-ft/in2  J/m2Unit
  • A: ± 1 J/m2 B: ± 2 J/m2Error

Mullen burst tester TP-K10

  • 0 to 5600 kPaMeasurement range
  • ± 0.5 % F.S.Accuracy
  • 170 ± 15 ml/minCompression speed
  • ≥ 690 kPaClamp pressure
Crush tester TP-L10
  • 5 to 500 N, 50 to 3000 NMeasurement range
  • 1 NResolution
  • ± 1 %Accuracy
  • ≤ 1 %Variability
COBB sample cutter TP-C30
  • 125 mmSample diameter
  • ± 0.2 mmSample error
  • 0.1 to 1.0 mmSample Thickness
  • 240×288×435 mmDimension

Standard strip cutter TP-G10

  • 15 mmSample width
  • 300 mmSample maximum length
  • ≤ 0.1 mmParallelism
  • 240×520×70 mmDimension

Whiteness meter TP-A11

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mmSystem
  • D65 as illuminating sourceLight source
  • ≤ 0.1 %Zero drift

Softness tester TP-H10

  • 10 to 1000 mNMeasuring range
  • 1 mNDivision value
  • ± 1%Accuracy
  • ≤ 0.5Indicating Error
Tensile Stiffness Tester TP-B10
  • 38×70 mmSample (size) length
  • (1-500) mN.m (divided into 7 small ranges)Measuring range
  • 0.02Indication error
  • (200° ± 20°)/ minTest speed
Mullen burst tester TP-K11
  • 0 to 1600 kPaMeasurement range
  • ± 0.5 % F.S.Accuracy
  • 95 ± 5 ml/minCompression speed
  • ≥ 430 kPaClamp pressure

Water absorption tester- Cobb Tester TP-C21

  • (100 ± 0.2) cm2Metal Cylinder inner area
  • 50 mmMetal Cylinder height
  • (200 ± 0..5) mmMetal roller width
  • (10 ± 0.5) kgMetal roller weight

Electronic Tearing tester TP-J21

  • 10 -16000 mNCapacity
  • 0.1 mNResolution
  • 104 ± 1 mmTearing arm
  • 27.5° ± 5°Tearing angle

Paper air permeability tester TP-J10

  • 0 to 1000 ml/minMeasuring range
  • 10 ± 0.02 cm2Test area
  • 1 ± 0.01 kPaArea differential pressure
  • 35.68 ± 0.05 mmInner diameter of grip ring
Water absorption tester TP-C20
  • 0 to 200 mmMeasurement range
  • 15×250 mmSpecimen size
  • 1 mmDivision value
  • 5Number of specimen holders
Paper and cardboard thickness meter TP-E20
  • 0 to 4 mmMeasuring range
  • 0.01 or 0.001 mmAccuracy
  • Analogue gauge displayGauge
  • 100 ± 10 kPaContact pressure (to create false weight)

Oxygen Index Tester TOIT-A10

  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time

Aging Oven TAO-A10

  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable
Vacuum Leak Tester TVLT-A10
  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size
Rubber Low Temperature Brittleness Tester TRBT-A11
  • Room temperature to -70 ℃ (room temperature ≤ 25 ℃)Temperature control range
  • ± 0.3 ℃Temperature accuracy
  • 0℃ to -30℃ around 2.5 ℃/min
    -30℃ to -40℃ around 2.5 ℃/min
    -40℃ to -70℃ around 2.0 ℃/min
    Impact speed
  • 910 × 510 × 860 mmMax dimension L × W × H

DIN abrasion tester TDAT-A10

  • 2.5 NTest arm weight
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,Additional Loads
  • 150 mmIdler
  • 40 ± 0.2 MAbrasion stroke

Three roll mill machine TRMM-A10

  • 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kgMixed capacity
  • RT to 300°CTemperature range
  • PID controlTemperature control system
  • LED displayDisplay
Benchtop gloss meter TBGM-A10
  • 60°Test angle
  • 2 × 3 mmGloss aperture
  • 0 to 1000 GUMeasurement range
  • 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)Repeatability
Rockwell hardness meter TRHM-A11
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 1 to 30 STotal test force dwell time
  • Digital displayHardness indication

Rockwell hardness meter TRHM-A10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 0 to 30 STotal test force dwell time
  • Analogue displayHardness indication

Rockwell hardness meter (motorized type) TRHM-B10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 306, 613, 1839 NBrinell hardness test
  • 294, 588, 980 NVickers hardness test
Soil nutrient tester TSNA-A10
  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Soil Salinity tester TSST-A10
  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy

Soil nutrient tester TSNA-A11

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error