Standard strip cutter TP-G10

Standard strip cutter TP-G10 with sleek and advanced design is used to cut the sheet of cardboard or paper into fine strips. It’s a common standard cutter which can cut the sample with 15 mm width. With user-friendly operation, it finds applications in paper & printing industry.

  • Sample size (L*B)
    Rub pressure
    Friction speed
    Friction area (L*B)
    No. of friction
    Measuring range
    Division value
    Accuracy
    Gauge
    Contact pressure (to create false weight)
    Contact diameter
    Error of depth parallelism
    Testing speed
    Test range
    Indicating Error
    Indication variability
    Pressing depth of the measuring head
    Parallelism error between two brims of the specimen stages
    Slit width of the specimen stage
    Testing length
    Sample size
    Bend angle
    Sample width 15 mm
    Sample maximum length 300 mm
    Parallelism ≤ 0.1 mm
    Dimension 240×520×70 mm
    Weight 4 kg
    Power supply
    • Advanced and sleek design
    • Sample width 15 mm
    • Sample maximum length 300 mm
    • Easy to use
  • Strip cutter is used in paper, packaging, inspection department, for paper crafts making industry.

Puncture strength tester TP-J12

  • A (1 to 6) J indicating error ± 0.05 J
    B (1 to 12) J indicating error ± 0.05 J
    C (1 to 24) J indicating error ± 0.05 J
    D (1 to 48) J indicating error ± 0.05 J
    The indicating errors w.r.t measurement range of 20 to 80 %
    Measuring range
  • <0.25 JFrictional resistance
  • Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mmPyramid dimension
  • 800×470×840 mmDimension

Electronic Tearing tester TP-J21

  • 10 -16000 mNCapacity
  • 0.1 mNResolution
  • 104 ± 1 mmTearing arm
  • 27.5° ± 5°Tearing angle

Automatic horizontal tensile tester TP-B12

  • 180 mm (180, 150, 100, 90, 50 mm adjustable)Sample (size) length
  • 15 mmSample width
  • 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 NMeasuring range
  • ± 1 %Accuracy
Mullen burst tester TP-K11
  • 0 to 1600 kPaMeasurement range
  • ± 0.5 % F.S.Accuracy
  • 95 ± 5 ml/minCompression speed
  • ≥ 430 kPaClamp pressure
Crush tester TP-L10
  • 5 to 500 N, 50 to 3000 NMeasurement range
  • 1 NResolution
  • ± 1 %Accuracy
  • ≤ 1 %Variability

Whiteness meter TP-A11

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mmSystem
  • D65 as illuminating sourceLight source
  • ≤ 0.1 %Zero drift

Paper and cardboard thickness meter TP-E20

  • 0 to 4 mmMeasuring range
  • 0.01 or 0.001 mmAccuracy
  • Analogue gauge displayGauge
  • 100 ± 10 kPaContact pressure (to create false weight)

Paper and cardboard thickness meter TP-E21

  • 0 to 20 mmMeasuring range
  • 0.01 mmAccuracy
  • Analogue gauge displayGauge
  • 20 ± 0.5 kPaContact pressure (to create false weight)
Electronic bending stiffness tester TP-E10
  • 200° ± 20° / minTesting speed
  • 1 to 10000 mNTest range
  • ± 1 %Indicating Error
  • 5, 10, 15, 20, 25, 50 mmTesting length
Bekk Smoothness tester TP-L20
  • ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)Measuring scope
  • ±0.1 s within 300 sAccuracy
  • Bigger volume: 380 ± 1
    Smaller volume: 38 ± 1
    Vacuum system volume (ml)
  • 100 ± 2 kPaContact pressure

Carton compression tester TP-I10

  • 0.1 to 10 kNMeasuring range
  • < ± 1%Indication error
  • 500×500 mm (customized)Platen Size
  • 500 mm (customized)Operating stroke

Pulp beating (refining) freeness tester TP-C10

  • 0 to 100° SRMeasurement range
  • 100 ± 10 mm/sSealed testing speed
  • 1000 ± 5 mlVolume of distilled water
  • 149 ± 1 sDraining time

Carton compression tester TP-I11

  • 1 to 50 kNMeasuring range
  • < ± 1%Indication error
  • 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)Platen Size
  • 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)Operating stroke
Tensile Stiffness Tester TP-B10
  • 38×70 mmSample (size) length
  • (1-500) mN.m (divided into 7 small ranges)Measuring range
  • 0.02Indication error
  • (200° ± 20°)/ minTest speed
Paper tearing tester TP-J20
  • 0 to 1000 mNMeasuring range
  • 0.1 mNResolution
  • ± 1 %Indication error
  • 104 ± 1 mmTearing arm

Oxygen Index Tester TOIT-A10

  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time

Aging Oven TAO-A10

  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable
Vacuum Leak Tester TVLT-A10
  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size
Benchtop gloss meter TBGM-A10
  • 60°Test angle
  • 2 × 3 mmGloss aperture
  • 0 to 1000 GUMeasurement range
  • 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)Repeatability

Rockwell hardness meter TRHM-A11

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 1 to 30 STotal test force dwell time
  • Digital displayHardness indication

Rockwell hardness meter TRHM-A10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 0 to 30 STotal test force dwell time
  • Analogue displayHardness indication
Rockwell hardness meter (motorized type) TRHM-B10
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 306, 613, 1839 NBrinell hardness test
  • 294, 588, 980 NVickers hardness test
Rubber Low Temperature Brittleness Tester TRBT-A11
  • Room temperature to -70 ℃ (room temperature ≤ 25 ℃)Temperature control range
  • ± 0.3 ℃Temperature accuracy
  • 0℃ to -30℃ around 2.5 ℃/min
    -30℃ to -40℃ around 2.5 ℃/min
    -40℃ to -70℃ around 2.0 ℃/min
    Impact speed
  • 910 × 510 × 860 mmMax dimension L × W × H

DIN abrasion tester TDAT-A10

  • 2.5 NTest arm weight
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,Additional Loads
  • 150 mmIdler
  • 40 ± 0.2 MAbrasion stroke

Three roll mill machine TRMM-A10

  • 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kgMixed capacity
  • RT to 300°CTemperature range
  • PID controlTemperature control system
  • LED displayDisplay
Soil nutrient tester TSNA-A11
  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Soil Salinity tester TSST-A10
  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy

Soil nutrient tester TSNA-A10

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error