Charpy/ Izod Impact Tester TCI-A10

Charpy/ Izod Impact Tester TCI-A10 comes with LCD digital display, pendulum design which concentrates energy at the impact point with minimum energy loss which occurs due to vibrations. It comes with broad range of measurement methods like test for split strength, impact intensity, fore elevation, ascending angle, statistics function, and automatic correction energy loss. With high precision & performance this charpy/ Izod Impact Tester is complied in accordance with ISO 179 for charpy, ISO 180, ASTM D256 for Izod test methods.

  • Impact Speed & Energy (charpy) 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J
    Impact energy (Izod) 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25J
    Resolution of impact energy 0.001 J
    Pendulum up angle 160°
    Impact center distance (Charpy) 221 mm for 1J, 2J, 4J, 5J & 380 mm 7.5J, 15J, 25J
    Impact center distance (Izod) 322 mm
    Charpy distance between the clamps 40 mm, 60 mm, 70 mm, 95 mm
    Radius of striking edge (IZOD) 0.8 mm
    Radius of striking edge (Charpy) 2.0 mm
    Distance between jaw & impact edge: 22mm
    Dimension 460×330×745 mm
    Weight 190 kg
    Power 110V/ 220V , 60Hz/ 50Hz
    • Innovative design impact tester used for both Izod and Charpy test
    • Adopted with LCD digital display to view measuring circle angle
    • Pendulum up angle 160°
    • Precise impact speed and center distance values for Charpy & Izod materials
    • Resolution of impact energy 0.001 J
    • Can be connected to mini printer to print results
  • It is used to test plastic sheets, glass-steel sheets, plastic pipe & other non-metallic materials sheets or insulators of plastic for anti-impact, anti- charpy intensity.

Lasting adhesive tester TLAT-A10

  • 2000 ± 50 gStandard roller
  • 3Testing stations
  • 320×210×550 mm (3 stations)Dimension (L*W*H) tester
  • 10 kg (3 stations)Weight for stations

Melt flow Indexer TMFI-A10

  • 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)Measuring range
  • 0.001 SMeasuring rate
  • 50 to 400°CTemperature range
  • ± 0.5°CTemperature precision

Heat sealer THS-A10

  • Room temperature -250°CSeal temperature
  • ± 0.2°CControl accuracy
  • 0.1 S to 999.9 SDwell time
  • 0.05 to 0.7 MPaDwell pressure
Aging Oven TAO-A10
  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable
Primary adhesive tester TPAT-A10
  • 0 to 40°Inclined adjustable angle
  • 120 mmPanel width
  • 80 mmTest area width
  • 1/32 to 1 inchStandard steel balls

Vacuum Leak Tester TVLT-A10

  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size

Falling Weight Impact Tester TFWT-A10

  • 10 to 35°CTemperature range
  • 2000 mmMaximum falling height
  • 1 mmResolution of displacement
  • < ± 2 mmHeight error

Oxygen Index Tester TOIT-A10

  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time
Lasting adhesive tester TLAT-A11
  • 2000 ± 50 gStandard roller
  • 6Testing stations
  • 650×210×550 mm (6 stations)Dimension (L*W*H) tester
  • 15 kg (6 stations)Weight for stations
Melt flow Indexer TMFI-A11
  • 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)Measuring range
  • 0.001 SMeasuring rate
  • 50 to 400°CTemperature range
  • ± 0.5°CTemperature precision

Vicat softening temperature & HDT machine TVHT-A10

  • Ambient temperature to 300°COperating temperature
  • 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)Heating rate
  • ± 5°C under 50°C/ h, ± 1°C under 120°C/ hMaximum temp. error with heating speed
  • 0 to 10 mmRange of deformation

Benchtop gloss meter TBGM-A10

  • 60°Test angle
  • 2 × 3 mmGloss aperture
  • 0 to 1000 GUMeasurement range
  • 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)Repeatability

Soil nutrient tester TSNA-A10

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Soil Salinity tester TSST-A10
  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy
Soil nutrient tester TSNA-A11
  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error

Whiteness and chromaticity tester TP-A10

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, bMeasurement mode
  • ≤ 0.1 within 30 minStability
  • Chromaticity co-ordinate 0.0001Accuracy

Whiteness meter TP-A11

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mmSystem
  • D65 as illuminating sourceLight source
  • ≤ 0.1 %Zero drift
Tensile Stiffness Tester TP-B10
  • 38×70 mmSample (size) length
  • (1-500) mN.m (divided into 7 small ranges)Measuring range
  • 0.02Indication error
  • (200° ± 20°)/ minTest speed
DIN abrasion tester TDAT-A10
  • 2.5 NTest arm weight
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,Additional Loads
  • 150 mmIdler
  • 40 ± 0.2 MAbrasion stroke

Rubber Low Temperature Brittleness Tester TRBT-A11

  • Room temperature to -70 ℃ (room temperature ≤ 25 ℃)Temperature control range
  • ± 0.3 ℃Temperature accuracy
  • 0℃ to -30℃ around 2.5 ℃/min
    -30℃ to -40℃ around 2.5 ℃/min
    -40℃ to -70℃ around 2.0 ℃/min
    Impact speed
  • 910 × 510 × 860 mmMax dimension L × W × H

Three roll mill machine TRMM-A10

  • 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kgMixed capacity
  • RT to 300°CTemperature range
  • PID controlTemperature control system
  • LED displayDisplay
Aging Oven TAO-A10
  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable
Vacuum Leak Tester TVLT-A10
  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size

Oxygen Index Tester TOIT-A10

  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time