Falling Weight Impact Tester TFWT-A10

Falling Weight Impact Tester TFWT-A10 is mainly used to calculate impact resistance of thermoplastic sheets, pipes and plastic fittings under given specified conditions of impact by means of falling weight. It determines anti-impact properties of plastic pipes, sheets and other products. This impact tester is adopted with PLC control & digital touch screen technology for controlling parts like proper figure setup, zero adjustment, preset dropping height, raising & dropping hammer. Adopted with pneumatic technology to prevent secondary impacts with 100 % capture rate.

  • Vacuum degree
    Accuracy
    Resolution
    Vacuum chamber effective size
    Vacuum chamber size
    Gas supply pressure
    Measuring range
    Precision
    Response time
    Display precision
    Output excursion
    Timer accuracy
    Temperature
    Relative humidity
    Working pressure
    Input pressure
    Temperature range 10 to 35°C
    Maximum falling height 2000 mm
    Resolution of displacement 1 mm
    Height error < ± 2 mm
    Hammer mass 0.25 to 16 kg
    Noses of strikers d25 to d90
    Dimension 730×700×3600 mm
    Power supply AC 220 V +/- 10 %, 50 Hz single phrase
    Net weight 300 kg
    Gross weight
    • Adopted with double pipe structure
    • Adopted with PLC controlled system
    • Digital touch screen technology
    • Adopted with pneumatic technology prevents secondary impacts
    • Determines anti-impact properties of materials
  • Falling Weight Impact Tester is used for impact testing strength of plastic sheets, pipes.

Heat sealer THS-A10

  • Room temperature -250°CSeal temperature
  • ± 0.2°CControl accuracy
  • 0.1 S to 999.9 SDwell time
  • 0.05 to 0.7 MPaDwell pressure

Lasting adhesive tester TLAT-A11

  • 2000 ± 50 gStandard roller
  • 6Testing stations
  • 650×210×550 mm (6 stations)Dimension (L*W*H) tester
  • 15 kg (6 stations)Weight for stations

Melt flow Indexer TMFI-A11

  • 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)Measuring range
  • 0.001 SMeasuring rate
  • 50 to 400°CTemperature range
  • ± 0.5°CTemperature precision
Aging Oven TAO-A10
  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable
Melt flow Indexer TMFI-A10
  • 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)Measuring range
  • 0.001 SMeasuring rate
  • 50 to 400°CTemperature range
  • ± 0.5°CTemperature precision

Primary adhesive tester TPAT-A10

  • 0 to 40°Inclined adjustable angle
  • 120 mmPanel width
  • 80 mmTest area width
  • 1/32 to 1 inchStandard steel balls

Charpy/ Izod Impact Tester TCI-A10

  • 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25JImpact Speed & Energy (charpy)
  • 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25JImpact energy (Izod)
  • 0.001 JResolution of impact energy
  • 160°Pendulum up angle

Vacuum Leak Tester TVLT-A10

  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size
Lasting adhesive tester TLAT-A10
  • 2000 ± 50 gStandard roller
  • 3Testing stations
  • 320×210×550 mm (3 stations)Dimension (L*W*H) tester
  • 10 kg (3 stations)Weight for stations
Oxygen Index Tester TOIT-A10
  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time

Vicat softening temperature & HDT machine TVHT-A10

  • Ambient temperature to 300°COperating temperature
  • 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)Heating rate
  • ± 5°C under 50°C/ h, ± 1°C under 120°C/ hMaximum temp. error with heating speed
  • 0 to 10 mmRange of deformation

Rockwell hardness meter (motorized type) TRHM-B10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 306, 613, 1839 NBrinell hardness test
  • 294, 588, 980 NVickers hardness test

Rockwell hardness meter TRHM-A10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 0 to 30 STotal test force dwell time
  • Analogue displayHardness indication
Rockwell hardness meter TRHM-A11
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 1 to 30 STotal test force dwell time
  • Digital displayHardness indication
Soil Salinity tester TSST-A10
  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy

Soil nutrient tester TSNA-A10

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error

Soil nutrient tester TSNA-A11

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Oxygen Index Tester TOIT-A10
  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time
Vacuum Leak Tester TVLT-A10
  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size

Aging Oven TAO-A10

  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable

Benchtop gloss meter TBGM-A10

  • 60°Test angle
  • 2 × 3 mmGloss aperture
  • 0 to 1000 GUMeasurement range
  • 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)Repeatability
Tensile Stiffness Tester TP-B10
  • 38×70 mmSample (size) length
  • (1-500) mN.m (divided into 7 small ranges)Measuring range
  • 0.02Indication error
  • (200° ± 20°)/ minTest speed
Whiteness and chromaticity tester TP-A10
  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, bMeasurement mode
  • ≤ 0.1 within 30 minStability
  • Chromaticity co-ordinate 0.0001Accuracy

Whiteness meter TP-A11

  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mmSystem
  • D65 as illuminating sourceLight source
  • ≤ 0.1 %Zero drift