Digital Brinell hardness Tester TDBH-A10

Digital Brinell Hardness Tester TDBH-A10 with advanced design tests the hardness of the material on Brinell scale. The traditional method of using heavy weights for Brinell testing is replaced by using photo/pressure sensor with more accurate results. It is used to determine the Brinell hardness of cast-iron, ferrous & non-ferrous metal, soft alloys & other nonmetallic materials. The digital display controls parameters like dwell time, test force etc.

  • Test force 612.5 N, 980 N, 1225 N
    Brinell hardness test 1837.5 N, 2450 N, 4900 N/7350 N, 9800 N, 14700 N/29400 N
    Hardness measuring area 8 to 650 HBW (hard metals steel ball)
    Hardness value symbol
    Error range in display
    Hardness indication Digital display
    Hardness value range in Measure
    Ball indenter 2.5, 5, 10 mm
    Magnification of Microscope 20x
    Loading control Automatic
    Standrad hardness block HBW/3000/10 with 150 to 250, HBW/1000/10 with 75 to 125, HBW/187.5/2.5 with 150 to 250
    Pressure holding time
    Min. measurable unit
    Maximum height of specimen 220 mm
    Maximum depth of specimen 135 mm
    Max. height of sample
    Distance from intenders center to outer wall
    Illumination light LED
    Main body weight 123 kg
    Dimension of machine 236 × 550 × 753 mm
    Power supply AC 220 V, 50 Hz
    • Digital LCD display
    • Electric auto loading
    • High power optical measurement
    • Automatic loading control, unloading & dwell
    • LED light as illumination source
    • Computer software program for operations
    • Photo sensor & other system
    • Hardness scale conversion
  • Digital Brinell hardness tester has applications in inspection, research, metal & other non-destructive material industry.

Rockwell hardness meter TRHM-A10

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 0 to 30 STotal test force dwell time
  • Analogue displayHardness indication

Rockwell hardness meter TRHM-A11

  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 1 to 30 STotal test force dwell time
  • Digital displayHardness indication

Portable Vibration Calibrator LPVC-A10

  • 10 Hz to1280 Hz + 0.01 %Frequency (continually adjustable)
  • 40 Hz to 320 Hz + 0.3 dB + 1 digitAmplitude acceleration ( at 30m/s2 pk )
  • 40 Hz to 320 Hz + 0.5dB +1 digitAmplitude velocity ( at 25mm / sec pk )
  • 40 Hz to 320 Hz + 0.5 dB + 1 digitAmplitude displacement ( at 50 μm pk-pk )
Rockwell hardness meter (motorized type) TRHM-B10
  • 98 NPreliminary test force
  • 588, 980, 1471 NTotal test force
  • 306, 613, 1839 NBrinell hardness test
  • 294, 588, 980 NVickers hardness test
Digital low load Vickers Hardness tester TDVH-A10
  • 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 NTest force
  • HV1, HV5, HV10, HV20, HV30, HV250Hardness value symbol
  • ± 3.0 %, ± 2.0 %Error range in display
  • Digital displayHardness indication

Vacuum Leak Tester TVLT-A10

  • 0 to 90 KPaVacuum degree
  • 1 % FSAccuracy
  • 0.1 KPaResolution
  • 270 × 210 mmVacuum chamber effective size

Aging Oven TAO-A10

  • 300°CThe maximum temperature
  • Within ± 0.5°CTemperature fluctuation
  • Within ± 1°CTemperature uniformity
  • 11 r/min to 12r/min, turntable dimension diameter: 285 mmRotate speed of the turntable
Oxygen Index Tester TOIT-A10
  • 0.1 % O2Resolution
  • 0 to 100 % O2Measuring range
  • ± 0.4 % O2Precision
  • < 10 SResponse time
Three roll mill machine TRMM-A10
  • 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kgMixed capacity
  • RT to 300°CTemperature range
  • PID controlTemperature control system
  • LED displayDisplay

Rubber Low Temperature Brittleness Tester TRBT-A11

  • Room temperature to -70 ℃ (room temperature ≤ 25 ℃)Temperature control range
  • ± 0.3 ℃Temperature accuracy
  • 0℃ to -30℃ around 2.5 ℃/min
    -30℃ to -40℃ around 2.5 ℃/min
    -40℃ to -70℃ around 2.0 ℃/min
    Impact speed
  • 910 × 510 × 860 mmMax dimension L × W × H

DIN abrasion tester TDAT-A10

  • 2.5 NTest arm weight
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,Additional Loads
  • 150 mmIdler
  • 40 ± 0.2 MAbrasion stroke
Whiteness meter TP-A11
  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mmSystem
  • D65 as illuminating sourceLight source
  • ≤ 0.1 %Zero drift
Whiteness and chromaticity tester TP-A10
  • Diameter ≥30 mm, Thickness ≤ 40 mmSample (size) length
  • Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, bMeasurement mode
  • ≤ 0.1 within 30 minStability
  • Chromaticity co-ordinate 0.0001Accuracy

Tensile Stiffness Tester TP-B10

  • 38×70 mmSample (size) length
  • (1-500) mN.m (divided into 7 small ranges)Measuring range
  • 0.02Indication error
  • (200° ± 20°)/ minTest speed

Soil nutrient tester TSNA-A11

  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Soil nutrient tester TSNA-A10
  • 0.001 to 9999Measuring range
  • A (absorbency of light) <0.003 within 3 minsStability
  • <3.0 %Linearity error
  • A (absorbency of light) <0.005Repeatability error
Soil Salinity tester TSST-A10
  • 0.00 to 19.99 ms/cmSalinity Measurement range
  • EC ± 2% full scaleMeasuring accuracy
  • -5 to 50°CTemperature Measurement range
  • ± 0.5°CTemperature accuracy

Benchtop gloss meter TBGM-A10

  • 60°Test angle
  • 2 × 3 mmGloss aperture
  • 0 to 1000 GUMeasurement range
  • 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)Repeatability