Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

  • Ambient temperature(-10)℃ ~ 35 ℃
  • Relative humidity≤ 85 %
  • Sample cup Inner diameter31.0 ~ 32.0 mm
  • Sample cup Wall thickness1.0 ~ 1.5 mm

Solidifying Point Tester LLTT-A13

  • Temperature controlling accuracy± 0.5 ℃
  • Refrigeration systemNew-type refrigeration compressor
  • Cold troughTwo holes in one trough, and same temperature
  • Ambient temperature≤ 30 ℃

Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15

  • Refrigeration systemNew-type refrigeration compressor
  • Controlling temperature of cold troughCold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
  • Ambient temperature≤ 30 ℃
  • Relative humidity≤ 85 %
Multifunctional Low Temperature Tester LLTT-A16
  • Refrigeration systemNew-type refrigeration compressor
  • Controlling temperature of cold troughCold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C
  • Ambient temperature≤ 30 ℃
  • Relative humidity≤ 85 %
Solidifying Point Tester LLTT-A20
  • Temperature controlling accuracy± 0.5 °C
  • Refrigeration systemNew-type refrigeration compressor
  • Cold troughOne trough with two baths, temperatures in two baths are equal
  • Controlling temperature of cold troughRoom temperature ~ (-70) °C

Solidifying Point Tester (Solidifying Point and Cold Filter Plugging Point) LLTT-A21

  • Refrigeration systemNew-type refrigeration compressor
  • Cold troughOne trough with two baths, temperatures in two baths are equal
  • Controlling temperature of cold troughRoom temperature ~ (-70) °C
  • Ambient temperature≤ 30 ℃

Solidifying Point Tester ('-20°C +80°C') LLTT-A22

  • Temperature controlling accuracy± 0.5 °C
  • Refrigeration systemNew-type refrigeration compressor
  • Cold troughOne trough with two baths, temperatures in two baths are equal
  • Controlling temperature of cold troughRoom temperature ~ (-70) °C

Automatic Pour Point Tester LLTT-A23

  • Ambient temperature≤ 30 ℃
  • Refrigeration speed> 40 °C / 10 min
  • Repeatability for solidifying point≤ 2 °C
  • Repeatability for pour point≤ 3 °C
Solidifying Point Constant Temperature Water Bath LLTT-A10
  • Capacity20 L
  • Temperature rangeAmbient +5°C to 100°C
  • Precision± 0.1℃
  • Stirring range1200 r/min
Freezing Point Tester LLTT-A11
  • Freezing point range-54°C to 2°C
  • Cold bath measurement temperature range-70° to 20°C
  • Temperature controlling accuracy±0.5°C
  • Bath liquids stirringElectric

Pour and Cloud Point Tester LLTT-A14

  • Chamber quantity2 chambers
  • Chamber 01 temperature controlAmbient to -51 ℃
  • Chamber 02 temperature controlAmbient to -65 ℃
  • Temperature precision±1°C