Automatic Pour Point Tester LLTT-A23

Labtron LLTT-A23 is manufactured with SCM as the core control system. It is also deliberately fabricated with colored touch screen, detecting sensor and semiconductor refrigeration technology. It is designed and made as per ASTM D2386 Standard Test Method for Solidifying Point of Petroleum Products, ASTM D97 Standard Test Method for Pour Point of Petroleum Products.

  • Measurement range
    Temperature controlling accuracy
    Refrigeration system
    Bath stirrer
    Sample stirrer
    Cold trough
    Controlling temperature of cold trough
    Constant temperature bath Cubage
    Constant temperature bath Types
    Temperature Range
    Temperature sensor
    Stirring motor Power
    Stirring motor Speed
    Ambient temperature ≤ 30 ℃
    Relative humidity
    Refrigeration speed > 40 °C / 10 min
    Repeatability for solidifying point ≤ 2 °C
    Repeatability for pour point ≤ 3 °C
    Reproducibility ± 4 °C
    Pressure of cooling water 0.5 kg / cm<sup>2</sup>
    The lowest temperature (-60) °C
    Sample cup Inner diameter
    Sample cup Wall thickness
    Sample cup Height
    Pumping pressure
    Dimensions 610 x 450 x 580 mm
    Inner Dimensions
    Outer Dimensions
    Total power consumption
    Heating power
    Power supply AC 220 V ± 10 %, 50 Hz
    • Test procedures are fully automatic
    • Data automation
    • Semiconductor for refrigeration, makes determination rapid
    • Solidifying point and pour point determination
    • LCD and graphic display
    • It can track and display the real-time temperature, and simulate the test status intelligently
  • It can be widely used in oil refineries, oil stations and other relevant institutions. It can be mainly used to determine the solidifying point and pour point of light oils which have good flow ability and low viscosity.

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

  • (-10)℃ ~ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 31.0 ~ 32.0 mmSample cup Inner diameter
  • 1.0 ~ 1.5 mmSample cup Wall thickness

Solidifying Point Tester LLTT-A20

  • ± 0.5 °CTemperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • One trough with two baths, temperatures in two baths are equalCold trough
  • Room temperature ~ (-70) °CControlling temperature of cold trough

Pour and Cloud Point Tester LLTT-A14

  • 2 chambersChamber quantity
  • Ambient to -51 ℃Chamber 01 temperature control
  • Ambient to -65 ℃Chamber 02 temperature control
  • ±1°CTemperature precision
Multifunctional Low Temperature Tester LLTT-A16
  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity
Solidifying Point Tester ('-20°C +80°C') LLTT-A22
  • ± 0.5 °CTemperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • One trough with two baths, temperatures in two baths are equalCold trough
  • Room temperature ~ (-70) °CControlling temperature of cold trough

Solidifying Point Tester LLTT-A13

  • ± 0.5 ℃Temperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • Two holes in one trough, and same temperatureCold trough
  • ≤ 30 ℃Ambient temperature

Solidifying Point Tester (Solidifying Point and Cold Filter Plugging Point) LLTT-A21

  • New-type refrigeration compressorRefrigeration system
  • One trough with two baths, temperatures in two baths are equalCold trough
  • Room temperature ~ (-70) °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature

Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15

  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity
Solidifying Point Constant Temperature Water Bath LLTT-A10
  • 20 LCapacity
  • Ambient +5°C to 100°CTemperature range
  • ± 0.1℃Precision
  • 1200 r/minStirring range
Freezing Point Tester LLTT-A11
  • -54°C to 2°CFreezing point range
  • -70° to 20°CCold bath measurement temperature range
  • ±0.5°CTemperature controlling accuracy
  • ElectricBath liquids stirring

Existent Gum Tester LEGT- B30

  • Oil bathBath type
  • 5000 ml ± 50 mlBath capacity
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity

Existent Gum Tester LEGT- B31

  • Aluminum block bath, φ260 × 130 mmEvaporation bath type and size
  • 3 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • Flow meterFlow rate display
Existent Gum Tester LEGT- B32
  • Aluminum bath φ260 × 130 mmEvaporation bath type and size
  • 5 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • 160 ℃ ~ 165℃Working temperature
Water Content Tester LWT-A11
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination

Coulometric Karl Fischer Titrator LWT-A30

  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed

Water Content Tester LWT-A10

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination
Water Soluble Acid and Alkali Tester LAAT-A10
  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature
Acid Number and Acidity Tester LAAT-A11
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption

Acid Number Tester LAAT-A12

  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

  • (-10)℃ ~ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 31.0 ~ 32.0 mmSample cup Inner diameter
  • 1.0 ~ 1.5 mmSample cup Wall thickness
Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15
  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity
Solidifying Point Tester LLTT-A13
  • ± 0.5 ℃Temperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • Two holes in one trough, and same temperatureCold trough
  • ≤ 30 ℃Ambient temperature

Constant Temperature Needle Penetration Tester LTNP-A10

  • 0 to 700 taper degree (digital display table 0-70 mm)Measuring range
  • Timing error is less than ±0.1 sTiming device
  • 0.01 mm Resolution
  • ±1 cone insertion degreeNeedle insertion accuracy