Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10 with removable cover design, automatically detects the refrigerating capacity and balance the circulation system w.r.t. last time caloric value. Need to open the lid to put the bomb inside the instrument. Equipped with advance small oxygen filling instrument with low malfunction rate.

  • Calorimeter type Isoperibol
    Temperature range 5 to 40°C
    Measurement range 5 to 40 MJ/ kg
    Operation Mode The outer barrel temperature is constant
    Temperature resolution 0.0001°C
    Precision RSD ≤0.1 %
    Testing time 8 min
    Power ≤1.5 kW
    Power supply 220 V, 50/60 Hz
    Dimension 540 × 420 × 420 mm
    Weight 45 kg
    • Semi-conductor water refrigeration system
    • Probe type electronic measuring cup to measure inner bucket water
    • No need to measure water and adjust water temperature
    • Auto stop and auto draining joints
    • Use of advance USB technology
    • Supports Windows system, links electronic scale, shares data via network
    • CE certified
  • Used in coal, petroleum, cement, farming, medical research, electronics for measurement of calorific value of solid and liquid combustible materials.

  • Accessories no. Name Unit Qty.
    1 Ignition thread (500 pieces) Box Box 20
    2 Standard Benzoic Acid (1 gm * 10 pieces) Bottle 10
    3 Gasket Ring for Oxygen Filling Facility (big, middle, small) Set 15
    4 Heating Crucible PC 60
    5 Oxygen bomb gasket ring (big, middle, small) Set 15
    6 Plastic insulation cover Set 5
    7 Special Oxygen filling pipe PC 2
    8 Electrodes Set 1

Automatic Bomb Calorimeter LABC-B10

  • IsoperibolCalorimeter type
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & loweringOxygen filling
  • 250 mlBomb volume
  • < 8 min full test process: <10 minAnalysis time

Automatic Bomb Calorimeter LABC-B11

  • IsoperibolCalorimeter type
  • Semi-automaticOxygen filling
  • 282 mlBomb volume
  • 15 to 25 minAnalysis time

Automatic Bomb Calorimeter LABC-A11

  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant modeOperation Mode

Rotational Viscometer LRV-A10

  • 10 ~ 2000000 MPa•sViscosity measurement range
  • 5 °C ~ 35 °CAmbient temperature
  • Not more than 80 %Ambient humidity
  • Four spindles of No.1 ~ 4Spindles

Mercaptan Sulfur Tester LMST-A10

  • (0 to ±1999.5) MvPotential measuring range
  • 0.1 % ±0.5 mVIntrinsic error
  • Ri ≥1 × 1012 ΩInput impedance
  • 10 mLBurette capacity
Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12
  • (-10)℃ ~ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 31.0 ~ 32.0 mmSample cup Inner diameter
  • 1.0 ~ 1.5 mmSample cup Wall thickness
Solidifying Point Tester LLTT-A13
  • ± 0.5 ℃Temperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • Two holes in one trough, and same temperatureCold trough
  • ≤ 30 ℃Ambient temperature

Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15

  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity

Automatic Thermogravimetric Analyzer LTGA-A10

  • Room temperature to 1000 ºC Temperature range
  • 0.1 ºCTemperature resolution
  • ±0.1 ºCTemperature fluctuation
  • 1 ~ 80 ºC / minHeating rate
Automatic Distillation Apparatus LADA-A10
  • 2 kWHeating power
  • 0.5 kWCooling power
  • 0 to 400℃Steam temperature
  • 0 to 500℃Oven temperature
Distillation Tester Dual Units LDT-A15
  • 100 mlGraduated flasks
  • 1mlScale division of graduated flask
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature

Benzene Distillation Tester (Low Temperature) LDT-A11

  • -10°C to 35°CAmbient temperature
  • ≤ 85 %Relative humidity
  • Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°CThermometer
  • 0.1 ℃Scale division