Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10 with removable cover design, automatically detects the refrigerating capacity and balance the circulation system w.r.t. last time caloric value. Need to open the lid to put the bomb inside the instrument. Equipped with advance small oxygen filling instrument with low malfunction rate.

  • Calorimeter type Isoperibol
    Temperature range 5 to 40°C
    Measurement range 5 to 40 MJ/ kg
    Operation Mode The outer barrel temperature is constant
    Temperature resolution 0.0001°C
    Precision RSD ≤0.1 %
    Testing time 8 min
    Power ≤1.5 kW
    Power supply 220 V, 50/60 Hz
    Dimension 540 × 420 × 420 mm
    Weight 45 kg
    • Semi-conductor water refrigeration system
    • Probe type electronic measuring cup to measure inner bucket water
    • No need to measure water and adjust water temperature
    • Auto stop and auto draining joints
    • Use of advance USB technology
    • Supports Windows system, links electronic scale, shares data via network
    • CE certified
  • Used in coal, petroleum, cement, farming, medical research, electronics for measurement of calorific value of solid and liquid combustible materials.

  • Accessories no. Name Unit Qty.
    1 Ignition thread (500 pieces) Box Box 20
    2 Standard Benzoic Acid (1 gm * 10 pieces) Bottle 10
    3 Gasket Ring for Oxygen Filling Facility (big, middle, small) Set 15
    4 Heating Crucible PC 60
    5 Oxygen bomb gasket ring (big, middle, small) Set 15
    6 Plastic insulation cover Set 5
    7 Special Oxygen filling pipe PC 2
    8 Electrodes Set 1

Automatic Bomb Calorimeter LABC-B11

  • IsoperibolCalorimeter type
  • Semi-automaticOxygen filling
  • 282 mlBomb volume
  • 15 to 25 minAnalysis time

Automatic Bomb Calorimeter LABC-B10

  • IsoperibolCalorimeter type
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & loweringOxygen filling
  • 250 mlBomb volume
  • < 8 min full test process: <10 minAnalysis time

Automatic Bomb Calorimeter LABC-A11

  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant modeOperation Mode

Distillate Fuel Oil Oxidation Stability Tester LOST-D12

  • 8Samples
  • 100 ℃Temperature
  • 0.1 ℃Temperature controlling accuracy
  • 3 ± 0.3 L / H oxygenFlow meter

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

  • 2Samples
  • 30 LOil bath cubage
  • 30 °Angle between bomb and water surface
  • 100 ± 5 RPMSpeed of rotary assembly
Transformer Oil Oxidation Stability Tester LOST-D11
  • 6Samples
  • Automatic digital temperatureTemperature controlling mode
  • Room temperature ~ 160 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
Automatic Distillation Apparatus LADA-A10
  • 2 kWHeating power
  • 0.5 kWCooling power
  • 0 to 400℃Steam temperature
  • 0 to 500℃Oven temperature

Distillation Tester Dual Units LDT-A15

  • 100 mlGraduated flasks
  • 1mlScale division of graduated flask
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature

Benzene Distillation Tester (Low Temperature) LDT-A11

  • -10°C to 35°CAmbient temperature
  • ≤ 85 %Relative humidity
  • Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°CThermometer
  • 0.1 ℃Scale division
Automatic Tag Closed Flash Point Tester LACF-A10
  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity
Mechanical Impurity Tester (Weight Method) LMIT-A21
  • 390 x 260 x 590 mmDimension
  • ≤ 1200 WTotal power consumption
  • AC 220 V ± 10 %, 50 HzPower supply
  • 1000 WHeating power of water bath

Insulating Oil Breakdown Voltage Tester LIBT-A23

  • AC 220 V ± 5 % , 50HzPower supply
  • 0 ~ 75 kVMeasurement range
  • 3 kV ± 10 % / sVoltage rising rate
  • 2.5 mmDistance between electrodes

Wax Oil Content Tester LWCT-A22

  • AC 220 V ± 10 %, 50 HzPower supply
  • RT ~ 90 ℃ ± 5 ℃Temperature controlling range in water bath
  • (-35) ℃ ± 1 ℃Cooling bath temperature
  • 35 ℃ ± 1 ℃Evaporation temperature
Water Content Tester LWT-A11
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination
Coulometric Karl Fischer Titrator LWT-A30
  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed

Water Content Tester LWT-A10

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination