Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10 with removable cover design, automatically detects the refrigerating capacity and balance the circulation system w.r.t. last time caloric value. Need to open the lid to put the bomb inside the instrument. Equipped with advance small oxygen filling instrument with low malfunction rate.

  • Calorimeter type Isoperibol
    Temperature range 5 to 40°C
    Measurement range 5 to 40 MJ/ kg
    Operation Mode The outer barrel temperature is constant
    Temperature resolution 0.0001°C
    Precision RSD ≤0.1 %
    Testing time 8 min
    Power ≤1.5 kW
    Power supply 220 V, 50/60 Hz
    Dimension 540 × 420 × 420 mm
    Weight 45 kg
    • Semi-conductor water refrigeration system
    • Probe type electronic measuring cup to measure inner bucket water
    • No need to measure water and adjust water temperature
    • Auto stop and auto draining joints
    • Use of advance USB technology
    • Supports Windows system, links electronic scale, shares data via network
    • CE certified
  • Used in coal, petroleum, cement, farming, medical research, electronics for measurement of calorific value of solid and liquid combustible materials.

  • Accessories no. Name Unit Qty.
    1 Ignition thread (500 pieces) Box Box 20
    2 Standard Benzoic Acid (1 gm * 10 pieces) Bottle 10
    3 Gasket Ring for Oxygen Filling Facility (big, middle, small) Set 15
    4 Heating Crucible PC 60
    5 Oxygen bomb gasket ring (big, middle, small) Set 15
    6 Plastic insulation cover Set 5
    7 Special Oxygen filling pipe PC 2
    8 Electrodes Set 1

Automatic Bomb Calorimeter LABC-A11

  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant modeOperation Mode

Automatic Bomb Calorimeter LABC-B11

  • IsoperibolCalorimeter type
  • Semi-automaticOxygen filling
  • 282 mlBomb volume
  • 15 to 25 minAnalysis time

Automatic Bomb Calorimeter LABC-B10

  • IsoperibolCalorimeter type
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & loweringOxygen filling
  • 250 mlBomb volume
  • < 8 min full test process: <10 minAnalysis time

Automatic Thermogravimetric Analyzer LTGA-A10

  • Room temperature to 1000 ºC Temperature range
  • 0.1 ºCTemperature resolution
  • ±0.1 ºCTemperature fluctuation
  • 1 ~ 80 ºC / minHeating rate

Acid Number and Acidity Tester LAAT-A11

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption
Acid Number Tester LAAT-A12
  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume
Water Soluble Acid and Alkali Tester LAAT-A10
  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature

Coulometric Karl Fischer Titrator LWT-A30

  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed

Water Content Tester LWT-A11

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination
Water Content Tester LWT-A10
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination
Automatic Dielectric Tester LADT-A10
  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity

Specific Gravity Tester LSGT-A10

  •  4000 ml × 2Vessel Volume
  • 160 WPower of Vacuum pump
  • 3.7 kPa(27.75 mmHg)Negative power
  • 30 WPower of shaking machine