Coulometric Karl Fischer Titrator LWT-A30

Coulometric Karl Fischer Titrator LWT-A30 is a benchtop unit with 10°C to 35°C ambient temperature range, 0 to 100 mg measurement range, and 10 µg to 1000 µg, ± 2 µg amount of electrolysed water range. Features fast and accurate water content determination with very simple process and portable handling unit. It is in accordance with ASTM D1533 (Standard Test Method for Water in Insulating Liquids by Coulometric Karl Fischer Titration) and ASTM D6304 (Standard Test Method for Determination of Water in Petroleum Products, Lubricating Oils, and Additives by Coulometric Karl Fischer Titration).

  • Ambient Temperature 10°C to 35°C
    Measurement Range 0 to 100 mg
    Resolution 0.1 µg
    Max. Electrolysis Speed 40 µg /s
    Amount and Precision of electrolysed water 10 µg to 1000 µg, ± 2 µg and >1000 µg, 0.2 %
    Relative Humidity ≤ 85 %
    Max. Power Consumption 30 W
    Power Supply AC 220 V ± 20 %, 50 Hz
    Dimension 320 × 240 × 150 mm
    Net Weight 5 kg
    • Capability of saving maximum 255 data
    • 240 × 128 pixels dot-matrix LCD screen
    • Equipped with Calendar clock, to record date and time
    • End point of sample is measured with high electrode precision value with electrolyte blank current and equilibrium point drift compensation adaptation for accurate measurement
    • Automatic shutdown LCD screen with screen protection function
    • Design with open-circuit fault and short-circuit fault for automatic detecting function of measuring electrode
    • Portable and easy handling
  • Coulometric Karl Fischer Titrator is used for the determination of water content in petroleum products and lubricating oils and additives by Karl Fischer titration

  • Item Quantity Unit
    Electrolyte 1 Bottle
    Electrolytic cell bottle(Measuring bottle with 5 openings) 1 Piece
    Measuring electrode 1 Piece
    Electrolysis electrode 1 Piece
    Silicone pad 10 Piece
    Silica gel bead 1 Pocket
    Printer paper 1 Roll
    Electrolytic cell inlet sample stopper 1 Piece
    Large glass ground stopper 1 Piece
    Small glass ground stopper (with notch) 1 Piece
    Small glass ground stopper 1 Piece
    Stirrer 2 Piece
    Power line 1 Piece
    Vacuum grease 1 Piece
    Sample filling device 0.5 µl 1 Piece
    Sample filling device 50 μl 1 Piece
    Sample filling device 1 ml 2 Piece
    Straight drying tube 1 Piece

Crude Petroleum Water Content Tester LWT-B10

  • -10 to 35°CAmbient Temperature Range
  • ≤85%Relative Humidity
  • 1000 mlDistillation Flask
  • 5 ml, with 0.05 ml graduationReceiver

Water Content Tester LWT-A10

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination

Coulometric Karl Fischer Titrator LWT-A31

  • 400 mAMaximum current
  • 3 µg to 9999.9 µgMeasurement range
  • 0.1 µgResolution
  • ± 2 µg (3µg H2O to 20µg H2O)Precision 1
Water Content Tester LWT-A11
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination

Ash Content Tester LACT-A10

  • {"Controlled\u00a0temperature":"775 \u00b125 \u2103","Temperature rising time of empty chamber":"\u2264 50 min","Furnace temperature uniformity":"\u2264 15\u2103","Internal dimension":"200 \u00d7 120 \u00d7 80 mm","External dimension":"490 \u00d7 490 \u00d7 450 mm","Power consumption":"2.5 kW","Power supply":"AC 220V \u00b110%, 50 Hz","Net weight":"35 kg"}Electric Muffle Furnace
  • {"Maximum control temperature":"1200 \u2103","Dimension":"500 \u00d7 300 \u00d7 235 mm","Power consumption":"5000 W","Power supply":"AC 220\u00b110% V, 50Hz","Net weight":"5 kg"}Temperature controller
  • {"Heating power":"(1 to 6) grades, continuously adjustable","Temperature":"400\u2103","Diameter of heating plate":"\u03a6 180 mm","Dimension":"280 \u00d7 250 \u00d7 90 mm","Power consumption":"2000 W","Power supply":"AC 220\u00b110%V, 50Hz"}Electric heating plate

Automatic Thermogravimetric Analyzer LTGA-A10

  • Room temperature to 1000 ºC Temperature range
  • 0.1 ºCTemperature resolution
  • ±0.1 ºCTemperature fluctuation
  • 1 ~ 80 ºC / minHeating rate
Aniline Point Tester LAPT-A10
  • Room temperature ~ 150°CMeasurement range
  • 0 ~ 1200 r / minStirring speed
  • 25 WHeating power
  • 360 × 250 × 545 mmInterior Dimension
Aniline Point Tester LAPT-A11
  • ≤ 0.5 ℃Temperature controlling accuracy
  • Room temperature ~ 200 ℃Temperature controlling range
  • 5 VPower supply for illumination
  • 2 kWPower of motor

Existent Gum Tester LEGT- B32

  • Aluminum bath φ260 × 130 mmEvaporation bath type and size
  • 5 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • 160 ℃ ~ 165℃Working temperature

Existent Gum Tester LEGT- B30

  • Oil bathBath type
  • 5000 ml ± 50 mlBath capacity
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
Existent Gum Tester LEGT- B31
  • Aluminum block bath, φ260 × 130 mmEvaporation bath type and size
  • 3 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • Flow meterFlow rate display
Portable Octane Number and Cetane Meter LOCT-A20
  • motor gasoline and dieselMeasurement item
  • 40 to 120measurement unit of octane is ON
  • ± 0.5 maxPermissible error of octane
  • ± 0.2 maxFluctuate range of octane

Octane Number and Cetane Number Tester LOCT-A10

  • 86.0 to 105.0/MON Measuring Range For Aviation Gasoline
  • National standard: 65.0 to 110.0/RON
    National-V standard: 70 to 115.0/RON
    Blended gasoline: 75.0 to 120.0/RON
    Light gasoline: 50.0 to 85.0 /MON
    Isomerized gasoline: 85.0 to 120.0/RON
    Arene gasoline: 90.0 to 120.0/RON
     Measuring Range For Gasoline For Motor Vehicles
  • E93: 92.0 to 95.0/RON
    E97: 95.0 to 99.0/RON
    Judgement: 60.0 to 120.0/RON
     Measuring Range For Ethanol
  • Cetane number: 25 to 75/CN
    Cetane index: 20 to 80/CI
    Measuring Range For Automobile Diesel Fuels