Coulometric Karl Fischer Titrator LWT-A30

Coulometric Karl Fischer Titrator LWT-A30 is a benchtop unit with 10°C to 35°C ambient temperature range, 0 to 100 mg measurement range, and 10 µg to 1000 µg, ± 2 µg amount of electrolysed water range. Features fast and accurate water content determination with very simple process and portable handling unit. It is in accordance with ASTM D1533 (Standard Test Method for Water in Insulating Liquids by Coulometric Karl Fischer Titration) and ASTM D6304 (Standard Test Method for Determination of Water in Petroleum Products, Lubricating Oils, and Additives by Coulometric Karl Fischer Titration).

  • Ambient Temperature 10°C to 35°C
    Measurement Range 0 to 100 mg
    Resolution 0.1 µg
    Max. Electrolysis Speed 40 µg /s
    Amount and Precision of electrolysed water 10 µg to 1000 µg, ± 2 µg and >1000 µg, 0.2 %
    Relative Humidity ≤ 85 %
    Max. Power Consumption 30 W
    Power Supply AC 220 V ± 20 %, 50 Hz
    Dimension 320 × 240 × 150 mm
    Net Weight 5 kg
    • Capability of saving maximum 255 data
    • 240 × 128 pixels dot-matrix LCD screen
    • Equipped with Calendar clock, to record date and time
    • End point of sample is measured with high electrode precision value with electrolyte blank current and equilibrium point drift compensation adaptation for accurate measurement
    • Automatic shutdown LCD screen with screen protection function
    • Design with open-circuit fault and short-circuit fault for automatic detecting function of measuring electrode
    • Portable and easy handling
  • Coulometric Karl Fischer Titrator is used for the determination of water content in petroleum products and lubricating oils and additives by Karl Fischer titration

  • Item Quantity Unit
    Electrolyte 1 Bottle
    Electrolytic cell bottle(Measuring bottle with 5 openings) 1 Piece
    Measuring electrode 1 Piece
    Electrolysis electrode 1 Piece
    Silicone pad 10 Piece
    Silica gel bead 1 Pocket
    Printer paper 1 Roll
    Electrolytic cell inlet sample stopper 1 Piece
    Large glass ground stopper 1 Piece
    Small glass ground stopper (with notch) 1 Piece
    Small glass ground stopper 1 Piece
    Stirrer 2 Piece
    Power line 1 Piece
    Vacuum grease 1 Piece
    Sample filling device 0.5 µl 1 Piece
    Sample filling device 50 μl 1 Piece
    Sample filling device 1 ml 2 Piece
    Straight drying tube 1 Piece

Coulometric Karl Fischer Titrator LWT-A31

  • 400 mAMaximum current
  • 3 µg to 9999.9 µgMeasurement range
  • 0.1 µgResolution
  • ± 2 µg (3µg H2O to 20µg H2O)Precision 1

Water Content Tester LWT-A11

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination

Crude Petroleum Water Content Tester LWT-B10

  • -10 to 35°CAmbient Temperature Range
  • ≤85%Relative Humidity
  • 1000 mlDistillation Flask
  • 5 ml, with 0.05 ml graduationReceiver
Water Content Tester LWT-A10
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination

Acid Number Tester LAAT-A12

  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume

Acid Number and Acidity Tester LAAT-A11

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption
Water Soluble Acid and Alkali Tester LAAT-A10
  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature
Kinematics Viscometer LKV-A13
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A11

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A12

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Penetrometer LMPT-A12
  • {"Measurement range":"0 to 600 penetration scale","Timing controller":"5 sec or 60 sec","Time accuracy":"\u00b1 0.1 seconds","Resolution":"0.1 penetration","Penetration accuracy":"\u00b1 1 penetration","Weight of standard needle":"2.5 \u00b1 0.05 g","Dimensions (W \u00d7 L \u00d7 H)":"700 \u00d7 400 \u00d7 750 mm","Weight":"30 kg"}Penetrometer
  • {"Bath volume":"3.5 L","Temperature range":"5 \u00b0C to 60 \u00b0C","Temperature accuracy":"\u00b1 0.1 \u00b0C","Circulatory water quantity":"3 L\/minute","Pump Lift":"2 m","Power consumption":"1200 W","Power supply":"AC 220V \u00b1 10 %, 50 Hz","Dimensions (W \u00d7 L \u00d7 H)":"600 \u00d7 400 \u00d7 650 mm","Weight":"40 kg"}Circulatory Water Bath
Penetrometer LMPT-A11
  • 0 to 600 penetration scaleMeasurement range
  • 5 sec or 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Penetrometer LMPT-A10

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Automatic PMCC Flash Point Tester LCFP-A11

  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point
PMCC Flash Point Tester LCFP-A10
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device
Automatic PMCC Flash Point Tester LCFP-A13
  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range

Automatic Tag Closed Flash Point Tester LACF-A10

  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity