Crude Petroleum Water Content Tester LWT-B10

Crude Petroleum Water Content Tester LWT-B10 designed as per ASTM D4006 Standard Test Method for Water in Crude Oil by Distillation. Widely used to determine the water content in crude oils. Features double unit, desktop structure, for simultaneous determination of two samples at a time.

  • Ambient Temperature Range -10 to 35°C
    Relative Humidity ≤85%
    Distillation Flask 1000 ml
    Receiver 5 ml, with 0.05 ml graduation
    Condenser 400 mm with ± 5 mm accuracy
    Heating Unit Heating mantle cap,
    Heating Mantle Cap Power 500 W × 2, continuous adjustment
    Sample Determination 2 at a time
    Dimension (exclusive of test vessels) 425 × 330 × 150 mm
    Dimension (Inclusive of test vessels) 425 × 330 × 1180 mm
    Dimension
    Power Supply AC 200 ± 10 % V, 50 Hz
    • Desktop structure, double unit design
    • Equipped with heating mantle cap, adjustable heating power
    • Standard design of distillation flask, receiver, and condenser
  • Used for determination of water content in crude oil, lubricants, petroleum oil and biofuels, other petrochemical products.

Coulometric Karl Fischer Titrator LWT-A30

  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed

Water Content Tester LWT-A11

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination

Coulometric Karl Fischer Titrator LWT-A31

  • 400 mAMaximum current
  • 3 µg to 9999.9 µgMeasurement range
  • 0.1 µgResolution
  • ± 2 µg (3µg H2O to 20µg H2O)Precision 1
Water Content Tester LWT-A10
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination

Foaming Characteristics Tester LFCT-A10

  • Ambient to 100°CTemperature Range
  • ± 0.1°CTemperature Precision
  • 94 mL ± 5 mL/min, with flowmetersAir Flow
  • 0 to 99 min 59 s, resolution 1 sTiming Unit

Engler Viscometer LEV-A10

  • 200 ± 0.2 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.2 °CTemperature Controlling Accuracy
Engler Viscometer LEV-A11
  • 100 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.1 °CTemperature Controlling Accuracy
Engler Viscometer LEV-B10
  • 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)Graduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • 10 °C ~ 40 °CAmbient Temperature

Constant Temperature Needle Penetration Tester LTNP-A10

  • 0 to 700 taper degree (digital display table 0-70 mm)Measuring range
  • Timing error is less than ±0.1 sTiming device
  • 0.01 mm Resolution
  • ±1 cone insertion degreeNeedle insertion accuracy

Density Tester LDMT-A10

  • Ф300 × 380 mmCubage of bath
  • 0 °C ~ 100 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
  • Industrial platinum resistance, Pt100Temperature sensor
Rotational Viscometer LRV-A10
  • 10 ~ 2000000 MPa•sViscosity measurement range
  • 5 °C ~ 35 °CAmbient temperature
  • Not more than 80 %Ambient humidity
  • Four spindles of No.1 ~ 4Spindles