Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

Labtron LOST-D10 is devised with Software-controlled test procedure which can check pressure, record test data and calculate oxidation time for measured sample automatically. Test curves and test data will be archived in database. It is made as per ASTM D2272 Standard

  • Samples 2
    Temperature
    Oil bath cubage 30 L
    Angle between bomb and water surface 30 °
    Speed of rotary assembly 100 ± 5 RPM
    Pressure sensor 0 to 1.6 Mpa; Accuracy: ±2%
    Oil bath Temperature controlling range RT to 200 °C (adjustable)
    Temperature controlling mode
    Temperature controlling range
    Temperature controlling accuracy ± 0.1 °C
    Flow meter
    Size 550 × 800 × 1000 mm
    Power of heater 2500 W
    Power supply 220 V ± 10 %
    Power consumption
    Weight 45 kg
    Dimension 860 × 710 × 104 mm
    • Fully Automatic
    • High test precision
    • Short heating-up time
    • Software-controlled test procedure
    • Data and test results will be archived in database
  • It is suitable to determine oxidation stability of new or in service turbine oil, which has the same components (base oil and additive). It is also a rapid method for determining the oxygen stability of new mineral insulating oils containing 2, 6-Di-tert-butyl-p-cresol.

Oxidation Stability Tester (Lubricating Grease) LOST-D20

  • Ambient to 150℃Temperature Range
  • ± 0.1°CTemperature Precision
  • 2 unitsTest Unit
  • 1800 WHeating Power

Gasoline Oxidation Stability Tester LOST-D13

  • Compact; DesktopType
  • IntegratedDesign
  • Metal bath (without water usage)Bath
  • 100℃ ± 1℃Temperature control point of metal bath

Transformer Oil Oxidation Stability Tester LOST-D11

  • 6Samples
  • Automatic digital temperatureTemperature controlling mode
  • Room temperature ~ 160 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
Distillate Fuel Oil Oxidation Stability Tester LOST-D12
  • 8Samples
  • 100 ℃Temperature
  • 0.1 ℃Temperature controlling accuracy
  • 3 ± 0.3 L / H oxygenFlow meter

Automatic Softening Point Tester LSPT-A10

  • 32 ℃ to 160 ℃Measurement range
  • 35 °CAmbient temperature
  • 0.01 ℃Temperature resolution
  • 1000 mLBeaker volume

Kinematics Viscometer LKV-A13

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A11
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A12
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Automatic COC Flash & Fire Point Tester LOFP-B10

  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability

Cleveland Open Cup Flash Point Tester LOFP-A11

  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature
Open Cup Flash Point Tester LOFP-A10
  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity
Water Content Tester LWT-A11
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination

Water Content Tester LWT-A10

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination

Coulometric Karl Fischer Titrator LWT-A30

  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed
Engler Viscometer LEV-A10
  • 200 ± 0.2 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.2 °CTemperature Controlling Accuracy
Engler Viscometer LEV-A11
  • 100 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.1 °CTemperature Controlling Accuracy

Engler Viscometer LEV-B10

  • 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)Graduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • 10 °C ~ 40 °CAmbient Temperature