Water Content Tester LWT-A10

Water Content Tester LWT-A10 is fabricated to determine water content in petroleum products and grease according to ASTM D95 (Test Methods for Water Content of Petroleum Products) and ASTM D7303 (Test Methods for Water Content in the Lubricating grease).

  • Ambient Temperature Range ≤ 35°C
    Relative Humidity ≤ 85%
    Distillation Flask
    Receiver
    Condenser
    Heating Unit
    Heating Mantle Cap Power 1000 W
    Sample Determination 1 at a time
    Dimension (exclusive of test vessels)
    Dimension (Inclusive of test vessels)
    Dimension 580 × 350 × 300 mm
    Power Supply AC 200 ± 10 % V, 50 Hz
    • Bidirectional Silicon Controlled Rectifier
    • Ambient Temperature is less than 35°C
    • Relative Humidity is less than 85%
    • Less power consumption
  • It is used to determine water content in crude oil, refined petroleum products, fuels, biofuels, lubricants, chemicals, and other products 

Crude Petroleum Water Content Tester LWT-B10

  • -10 to 35°CAmbient Temperature Range
  • ≤85%Relative Humidity
  • 1000 mlDistillation Flask
  • 5 ml, with 0.05 ml graduationReceiver

Water Content Tester LWT-A11

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination

Coulometric Karl Fischer Titrator LWT-A31

  • 400 mAMaximum current
  • 3 µg to 9999.9 µgMeasurement range
  • 0.1 µgResolution
  • ± 2 µg (3µg H2O to 20µg H2O)Precision 1
Coulometric Karl Fischer Titrator LWT-A30
  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed

Mercaptan Sulfur Tester LMST-A10

  • (0 to ±1999.5) MvPotential measuring range
  • 0.1 % ±0.5 mVIntrinsic error
  • Ri ≥1 × 1012 ΩInput impedance
  • 10 mLBurette capacity

Automatic Tag Closed Flash Point Tester LACF-A10

  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity
Foaming Characteristics Tester LFCT-A10
  • Ambient to 100°CTemperature Range
  • ± 0.1°CTemperature Precision
  • 94 mL ± 5 mL/min, with flowmetersAir Flow
  • 0 to 99 min 59 s, resolution 1 sTiming Unit
Acid Number and Acidity Tester LAAT-A11
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption

Water Soluble Acid and Alkali Tester LAAT-A10

  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature

Acid Number Tester LAAT-A12

  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume
Engler Viscometer LEV-A10
  • 200 ± 0.2 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.2 °CTemperature Controlling Accuracy
Engler Viscometer LEV-A11
  • 100 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.1 °CTemperature Controlling Accuracy

Engler Viscometer LEV-B10

  • 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)Graduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • 10 °C ~ 40 °CAmbient Temperature