Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10 is benchtop unit designed to measure Motor octane number (MON) of aviation gasoline, light gasoline; Research octane number (RON) of gasoline for motor vehicles, blended gasoline, isomerised gasoline, arene gasoline, ethanol and Cetane number of automobile diesel fuel. Test results meets the standards of ASTM D2699-86 and ASTM D613 - 18a. Features like digital transmission technology, anti-jamming, accurate results after several repetitions, less sample volume, short test time, LCD display etc. makes it highly reliable. It is widely used in testing labs, petroleum industry, quality control, etc.

  •  Measuring Range For Aviation Gasoline 86.0 to 105.0/MON
     Measuring Range For Gasoline For Motor Vehicles National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
     Measuring Range For Ethanol E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON
    Measuring Range For Automobile Diesel Fuels Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI
    Measuring Accuracy Aviation gasoline: ≤ ± 1.5/MON<br/> Gasoline for motor vehicles: ≤ ± 1.5/RON, ≤ ± 1.5/MO<br/> Automobile diesel fuels: ≤ ± 2.6/CN, ≤ ± 2.6/CI<br/> Regression sample retest: ≤ ± 0.5/RON, ≤ ± 0.5/MON<br/> Regression sample measurement: ≤ ± 1.5/RON, ≤ ± 1.5/MON<br/> Calibration accuracy: ≤ ± 0.2/RON, ≤ ± 0.2/MON
    Precision (Confidence Level 95%) Reproducibility: ≤ ± 0.5/RON<br/> Repeatability: ≤ ± 0.2/RON
    Minimum Scale 0.1/RON,    0.1/MON,   0.1/CI
    Response Time 1 min
    Ambient Temperature 10°C to 35°C
    Humidity < 85% RH
    Test Result LCD display, it can store and print
    Power Supply AC (220 ± 10%) V, (50 ± 1) Hz
    • Octane number test results meets the standards of ASTM D2699-86
    • Diesel fuel test results meets the standards of ASTM D613 - 18a
    • Highly precise sensors
    • Displays RON, MON and AK (antiknock) index simultaneously
    • Calculates Cetane number automatically
    • Digital transmission technology to transfer data
    • Least variation in values
    • Requires only 150 ml of test sample
    • Results displayed within 1 min
    • LCD display
    • Can store data
  • It is used in petroleum and oil industry to determine MON, RON, AK index values for gasoline and Cetane number for diesel.

Portable Octane Number and Cetane Meter LOCT-A20

  • motor gasoline and dieselMeasurement item
  • 40 to 120measurement unit of octane is ON
  • ± 0.5 maxPermissible error of octane
  • ± 0.2 maxFluctuate range of octane

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

  • 2Samples
  • 30 LOil bath cubage
  • 30 °Angle between bomb and water surface
  • 100 ± 5 RPMSpeed of rotary assembly

Distillate Fuel Oil Oxidation Stability Tester LOST-D12

  • 8Samples
  • 100 ℃Temperature
  • 0.1 ℃Temperature controlling accuracy
  • 3 ± 0.3 L / H oxygenFlow meter
Transformer Oil Oxidation Stability Tester LOST-D11
  • 6Samples
  • Automatic digital temperatureTemperature controlling mode
  • Room temperature ~ 160 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
Density Tester LDMT-A10
  • Ф300 × 380 mmCubage of bath
  • 0 °C ~ 100 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
  • Industrial platinum resistance, Pt100Temperature sensor

Benzene Distillation Tester (Low Temperature) LDT-A11

  • -10°C to 35°CAmbient temperature
  • ≤ 85 %Relative humidity
  • Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°CThermometer
  • 0.1 ℃Scale division

Distillation Tester Dual Units LDT-A15

  • 100 mlGraduated flasks
  • 1mlScale division of graduated flask
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature
Automatic Distillation Apparatus LADA-A10
  • 2 kWHeating power
  • 0.5 kWCooling power
  • 0 to 400℃Steam temperature
  • 0 to 500℃Oven temperature
Specific Gravity Tester LSGT-A10
  •  4000 ml × 2Vessel Volume
  • 160 WPower of Vacuum pump
  • 3.7 kPa(27.75 mmHg)Negative power
  • 30 WPower of shaking machine

Automatic Dielectric Tester LADT-A10

  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity