Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10 is benchtop unit designed to measure Motor octane number (MON) of aviation gasoline, light gasoline; Research octane number (RON) of gasoline for motor vehicles, blended gasoline, isomerised gasoline, arene gasoline, ethanol and Cetane number of automobile diesel fuel. Test results meets the standards of ASTM D2699-86 and ASTM D613 - 18a. Features like digital transmission technology, anti-jamming, accurate results after several repetitions, less sample volume, short test time, LCD display etc. makes it highly reliable. It is widely used in testing labs, petroleum industry, quality control, etc.

  •  Measuring Range For Aviation Gasoline 86.0 to 105.0/MON
     Measuring Range For Gasoline For Motor Vehicles National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
     Measuring Range For Ethanol E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON
    Measuring Range For Automobile Diesel Fuels Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI
    Measuring Accuracy Aviation gasoline: ≤ ± 1.5/MON<br/> Gasoline for motor vehicles: ≤ ± 1.5/RON, ≤ ± 1.5/MO<br/> Automobile diesel fuels: ≤ ± 2.6/CN, ≤ ± 2.6/CI<br/> Regression sample retest: ≤ ± 0.5/RON, ≤ ± 0.5/MON<br/> Regression sample measurement: ≤ ± 1.5/RON, ≤ ± 1.5/MON<br/> Calibration accuracy: ≤ ± 0.2/RON, ≤ ± 0.2/MON
    Precision (Confidence Level 95%) Reproducibility: ≤ ± 0.5/RON<br/> Repeatability: ≤ ± 0.2/RON
    Minimum Scale 0.1/RON,    0.1/MON,   0.1/CI
    Response Time 1 min
    Ambient Temperature 10°C to 35°C
    Humidity < 85% RH
    Test Result LCD display, it can store and print
    Power Supply AC (220 ± 10%) V, (50 ± 1) Hz
    • Octane number test results meets the standards of ASTM D2699-86
    • Diesel fuel test results meets the standards of ASTM D613 - 18a
    • Highly precise sensors
    • Displays RON, MON and AK (antiknock) index simultaneously
    • Calculates Cetane number automatically
    • Digital transmission technology to transfer data
    • Least variation in values
    • Requires only 150 ml of test sample
    • Results displayed within 1 min
    • LCD display
    • Can store data
  • It is used in petroleum and oil industry to determine MON, RON, AK index values for gasoline and Cetane number for diesel.

Portable Octane Number and Cetane Meter LOCT-A20

  • motor gasoline and dieselMeasurement item
  • 40 to 120measurement unit of octane is ON
  • ± 0.5 maxPermissible error of octane
  • ± 0.2 maxFluctuate range of octane

Engler Viscometer LEV-A11

  • 100 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.1 °CTemperature Controlling Accuracy

Engler Viscometer LEV-B10

  • 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)Graduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • 10 °C ~ 40 °CAmbient Temperature
Engler Viscometer LEV-A10
  • 200 ± 0.2 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.2 °CTemperature Controlling Accuracy
Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11
  • Not less than 150 L / hAir flow rate
  • 99 min 59 s (100 min)Max. Preset time
  • Φ22 mmChamber diameter of oven
  • 1400 W × 2Heating power of oven

X-ray Fluorescence Sulfur in Oil Analyzer LST-A10

  • 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)Sample quantity
  • 60, 120, 240, 300, and 600 s at randomMeasurement time
  • 7 ppm to 5 %Measurement range
  • < 0.029 (S + 0.6)Repeatability

Automatic COC Flash & Fire Point Tester LOFP-B10

  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability
Cleveland Open Cup Flash Point Tester LOFP-A11
  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature
Open Cup Flash Point Tester LOFP-A10
  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity

Automatic Bomb Calorimeter LABC-B10

  • IsoperibolCalorimeter type
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & loweringOxygen filling
  • 250 mlBomb volume
  • < 8 min full test process: <10 minAnalysis time

Automatic Bomb Calorimeter LABC-A10

  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • The outer barrel temperature is constantOperation Mode
Automatic Bomb Calorimeter LABC-A11
  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant modeOperation Mode
Copper Strip Corrosion Tester LRCT-A13
  • 4 piecesSample hole
  • 4 to 12 piecesSample quantity
  • Room temperature to 35 °CAmbient temperature
  • Room temperature to 100°CTemperature controlling range

Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10

  • 2 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 10 to 35°CAmbient temperature
  • Room Temperature to 100°CTemperature controlling range

Lubricating Oil Rust Characteristics Tester LRCT-A11

  • 4 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 1000 ± 50 rpmSpeed for sample stirring
  • Room temperature to 35°CAmbient temperature