Automatic Distillation Apparatus LADA-A10 is a benchtop unit which can automatically determine the distillation range of petroleum products. Test procedures like heating, distillation speed and recording the data are fully automated. Large LCD display and easy to handle operations makes it highly convenient to use. It complies with ASTM D86 and IP123 standards.

  • Heating power 2 kW
    Cooling power 0.5 kW
    Steam temperature 0 to 400℃
    Oven temperature 0 to 500℃
    Refrigeration temperature 0 to 60℃
    Refrigeration accuracy ± 1℃
    Temperature measurement accuracy ± 0.1℃
    Volume accuracy ± 0.1 ml
    Power AC 220 V ± 10% 50 Hz
    • 10'' LCD touch screen to view and pre-set several parameters
    • Highly advance level tracking system with American Haydon high-stepping linear motor
    • Imported integral linear ball screw circumferential positioning laser tracker
    • Imported Danfoss (Secop) Compressor
    • Mechanically refrigerated cooling tube and cylinder room
    • Automatic heating control (distillation process): up to 95% sample heating control with controlled flow rate of 4 to 5 ml/min
    • Display shows initial and final boiling point temperature, various % temperature and flow rate
    • Automatic correction of local atmospheric pressure to standard atmospheric pressure
    • Test process is stopped by temperature of steam
    • Results can be stored and printed
  • It is widely used to determine the distillation range of various petroleum products in laboratories, research institutes and industries.

Vacuum Distillation Tester LDT-A13

  • 5 °C to 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 1000 mlCubage of buffer vessel
  • ≤ 2 mm HgMax. Residual pressure

Benzene Distillation Tester (Low Temperature) LDT-A11

  • -10°C to 35°CAmbient temperature
  • ≤ 85 %Relative humidity
  • Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°CThermometer
  • 0.1 ℃Scale division

Distillation Tester LDT-A12

  • 100 mlGraduated flasks
  • 1 mlScale division of graduated flask
  • φ65Outer diameter of distillation flask
  • φ14Refrigeration tube
Distillation Tester Front Type LDT-A14
  • 125 mLDistillation flask
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • (-2 )°C to 300 ℃ and (-2) °C to 400 ℃Thermometer
Distillation Tester LDT-A10
  • 10 ml and 100 mlGraduated flasks
  • 10 ml is 0.1 ml and 100 ml is 1 mlScale division of graduated flask
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity

Distillation Tester (low temperature single unit) LDT-A17

  • 100 mlGraduated flasks
  • 125 mLDistillation flask
  • ≤ 30 °CAmbient temperature
  • ≤ 85 %Relative humidity

Distillation Tester (low temperature Double units) LDT-A16

  • 100 mlGraduated flasks
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity

Distillation Tester Dual Units LDT-A15

  • 100 mlGraduated flasks
  • 1mlScale division of graduated flask
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature

Oxygen Bomb Calorimeter LBC-C22

  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
  • 15 ~ 28 ℃Operation environment temperature

Oxygen Bomb Calorimeter LBC-C20

  • 14000 ~ 15000 J / KHeat capacity
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
Oxygen Bomb Calorimeter LBC-C21
  • 10 ℃ ~ 35 ℃Temperature controlling range
  • 0.001 ℃Temperature resolution
  • 15 kJ / KMean value of heat capacity
  • 20 ℃ ± 5 ℃Ambient temperature
Automatic COC Flash & Fire Point Tester LOFP-B10
  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability

Cleveland Open Cup Flash Point Tester LOFP-A11

  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature

Open Cup Flash Point Tester LOFP-A10

  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity
Solidifying Point Tester LLTT-A13
  • ± 0.5 ℃Temperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • Two holes in one trough, and same temperatureCold trough
  • ≤ 30 ℃Ambient temperature
Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15
  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

  • (-10)℃ ~ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 31.0 ~ 32.0 mmSample cup Inner diameter
  • 1.0 ~ 1.5 mmSample cup Wall thickness

Specific Gravity Tester LSGT-A10

  •  4000 ml × 2Vessel Volume
  • 160 WPower of Vacuum pump
  • 3.7 kPa(27.75 mmHg)Negative power
  • 30 WPower of shaking machine
Constant Temperature Needle Penetration Tester LTNP-A10
  • 0 to 700 taper degree (digital display table 0-70 mm)Measuring range
  • Timing error is less than ±0.1 sTiming device
  • 0.01 mm Resolution
  • ±1 cone insertion degreeNeedle insertion accuracy