Aniline Point Tester LAPT-A10

Labtron LAPT-A10 is designed with stepless speed regulation motor to have a smoother operation and automatic alarm system with sound and light to detect end point. It is designed and made as per ASTM D611 “Test Methods for Aniline Point of Petroleum Products”.

  • Measurement range Room temperature ~ 150°C
    Stirring speed 0 ~ 1200 r / min
    Heating power 25 W
    Interior Dimension 360 × 250 × 545 mm
    Exterior Dimension 370 × 320 × 630 mm
    Power supply AC 220 V ± 10 %, 50 Hz
    Temperature controlling accuracy
    Temperature controlling range
    Power supply for illumination
    Power of motor
    • Electric heater to heat sample
    • Reliable and convenient
    • Controlling temperature can be adjusted manually
    • Highly accurate
  • It can be widely used in petroleum, chemical industries, research and development laboratories.

Aniline Point Tester LAPT-A11

  • ≤ 0.5 ℃Temperature controlling accuracy
  • Room temperature ~ 200 ℃Temperature controlling range
  • 5 VPower supply for illumination
  • 2 kWPower of motor

Lubricating Oil Rust Characteristics Tester LRCT-A11

  • 4 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 1000 ± 50 rpmSpeed for sample stirring
  • Room temperature to 35°CAmbient temperature

Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10

  • 2 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 10 to 35°CAmbient temperature
  • Room Temperature to 100°CTemperature controlling range
Copper Strip Corrosion Tester LRCT-A13
  • 4 piecesSample hole
  • 4 to 12 piecesSample quantity
  • Room temperature to 35 °CAmbient temperature
  • Room temperature to 100°CTemperature controlling range
Engler Viscometer LEV-A11
  • 100 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.1 °CTemperature Controlling Accuracy

Engler Viscometer LEV-B10

  • 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)Graduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • 10 °C ~ 40 °CAmbient Temperature

Engler Viscometer LEV-A10

  • 200 ± 0.2 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.2 °CTemperature Controlling Accuracy
Carbon Residue Tester (CONRADSON METHODS) LRCT-B10
  • 30 mlPorcelain crucible
  • 75 mlInner iron crucible
  • 190 mlOuter iron crucible
  • Mig BurnerBurner
Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11
  • Four holes with a furnaceBath type
  • Electric resistance furnaceHeating type
  • 0 ~ 520 °CTemperature controlling range
  • ± 5 °CTemperature controlling accuracy

Carbon Residue Tester (Ramsbottom) LRCT-B20

  • Metal furnaceCoking furnace
  • Electric heatingHeating mode
  • 5 unitsTest unit
  • Ambient to 550°CTemperature range

Mercaptan Sulfur Tester LMST-A10

  • (0 to ±1999.5) MvPotential measuring range
  • 0.1 % ±0.5 mVIntrinsic error
  • Ri ≥1 × 1012 ΩInput impedance
  • 10 mLBurette capacity
PMCC Flash Point Tester LCFP-A10
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device
Automatic PMCC Flash Point Tester LCFP-A11
  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point

Automatic PMCC Flash Point Tester LCFP-A13

  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range