Oxygen Bomb Calorimeter LBC-C21

Labtron LBC-C21 is designed with high precision sensor and microprocessor to get reliable and accurate results. It is designed and made as per the International Standards ASTM D5865-13 “Test Methods for Heat of Coal”, ASTM D240-17 “Test Methods for Calorific Value of Petroleum Products” and ASTM D4809-13“Oxygen Bomb Calorimeter”.

  • Heat capacity
    Temperature measurement range
    Temperature controlling range 10 ℃ ~ 35 ℃
    Repeatability error
    Endured pressure in oxygen bomb
    Operation environment temperature
    Temperature resolution 0.001 ℃
    Mean value of heat capacity 15 kJ / K
    Heating power
    Temperature fluctuation
    Ambient temperature 20 ℃ ± 5 ℃
    Relative humidity ≤ 85 %
    Endured pressure of oxygen bomb 20 MPa Test pressure in oxygen bomb: 3 MPa
    Temperature saved 31 pieces
    Measurement accuracy for heat value ≤ 0.2 %
    Dimension 400 × 400 × 600 mm
    weight 18 kg
    Power supply
    • High precision sensor
    • Accurate and reliable
    • Microprocessor for control and led for display
    • Stirring motor has no noise
    • Easy transportation
  • It is mainly used in petroleum, chemical, automobile and development industries. It is suitable for determining heat value of petroleum products (Gasoline, jet fuels, diesel oil and fuel oils), which do not contain water, coal, paraffin and other combustible substance.

Oxygen Bomb Calorimeter LBC-C20

  • 14000 ~ 15000 J / KHeat capacity
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb

Oxygen Bomb Calorimeter LBC-C22

  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
  • 15 ~ 28 ℃Operation environment temperature

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11

  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Room temperature to 99.9 °CTemperature controlling range
  • ± 1 °CTemperature controlling accuracy

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10

  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 1 s to 9 min 59 sTiming range
  • Room temperature to 99.9 °CTemperature controlling range
Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11
  • Four holes with a furnaceBath type
  • Electric resistance furnaceHeating type
  • 0 ~ 520 °CTemperature controlling range
  • ± 5 °CTemperature controlling accuracy
Carbon Residue Tester (Ramsbottom) LRCT-B20
  • Metal furnaceCoking furnace
  • Electric heatingHeating mode
  • 5 unitsTest unit
  • Ambient to 550°CTemperature range

Carbon Residue Tester (CONRADSON METHODS) LRCT-B10

  • 30 mlPorcelain crucible
  • 75 mlInner iron crucible
  • 190 mlOuter iron crucible
  • Mig BurnerBurner

Engler Viscometer LEV-A11

  • 100 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.1 °CTemperature Controlling Accuracy
Engler Viscometer LEV-A10
  • 200 ± 0.2 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.2 °CTemperature Controlling Accuracy
Engler Viscometer LEV-B10
  • 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)Graduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • 10 °C ~ 40 °CAmbient Temperature

Octane Number and Cetane Number Tester LOCT-A10

  • 86.0 to 105.0/MON Measuring Range For Aviation Gasoline
  • National standard: 65.0 to 110.0/RON
    National-V standard: 70 to 115.0/RON
    Blended gasoline: 75.0 to 120.0/RON
    Light gasoline: 50.0 to 85.0 /MON
    Isomerized gasoline: 85.0 to 120.0/RON
    Arene gasoline: 90.0 to 120.0/RON
     Measuring Range For Gasoline For Motor Vehicles
  • E93: 92.0 to 95.0/RON
    E97: 95.0 to 99.0/RON
    Judgement: 60.0 to 120.0/RON
     Measuring Range For Ethanol
  • Cetane number: 25 to 75/CN
    Cetane index: 20 to 80/CI
    Measuring Range For Automobile Diesel Fuels

Portable Octane Number and Cetane Meter LOCT-A20

  • motor gasoline and dieselMeasurement item
  • 40 to 120measurement unit of octane is ON
  • ± 0.5 maxPermissible error of octane
  • ± 0.2 maxFluctuate range of octane
Penetrometer LMPT-A12
  • {"Measurement range":"0 to 600 penetration scale","Timing controller":"5 sec or 60 sec","Time accuracy":"\u00b1 0.1 seconds","Resolution":"0.1 penetration","Penetration accuracy":"\u00b1 1 penetration","Weight of standard needle":"2.5 \u00b1 0.05 g","Dimensions (W \u00d7 L \u00d7 H)":"700 \u00d7 400 \u00d7 750 mm","Weight":"30 kg"}Penetrometer
  • {"Bath volume":"3.5 L","Temperature range":"5 \u00b0C to 60 \u00b0C","Temperature accuracy":"\u00b1 0.1 \u00b0C","Circulatory water quantity":"3 L\/minute","Pump Lift":"2 m","Power consumption":"1200 W","Power supply":"AC 220V \u00b1 10 %, 50 Hz","Dimensions (W \u00d7 L \u00d7 H)":"600 \u00d7 400 \u00d7 650 mm","Weight":"40 kg"}Circulatory Water Bath
Penetrometer LMPT-A10
  • 0 to 600 penetration scaleMeasurement range
  • 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Penetrometer LMPT-A11

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec or 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution