Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10

Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10 is a desktop model, good pressure and corrosion resistance. This instrument is designed and made as per International Standard of Petrochemical ASTM D130 (Test Methods for Detection of Copper Corrosion from Liquefied Petroleum Gas by the Copper Strip Tarnish Test).

  • Sample hole 2 pieces
    Speed of stirring motor 1400 rpm
    Ambient temperature 10 to 35°C
    Temperature controlling range Room Temperature to 100°C
    Temperature controlling accuracy ± 0.5°C
    Temperature controller Pt100
    Relative humidity ≤ 85 %
    Delay time 0.01 s to 99 hours 99 minutes
    Heating power 600 W for temperature controlling; 1000 W for auxiliary heating
    Total power consumption ≤ 1700 W
    Dimensions 580 × 520 × 810 mm
    Power supply AC 220 V ± 10 %, 50 Hz
    • Digital temperature controller
    • Stainless steel material test bombs
    • Uniform temperature of water bath and high precision control
    • Equipped with standard color board and copper strips
    • Easy to operate
  • It is suitable to determine corrosiveness of liquefied petroleum gas to copper strip.

Lubricating Oil Rust Characteristics Tester LRCT-A11

  • 4 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 1000 ± 50 rpmSpeed for sample stirring
  • Room temperature to 35°CAmbient temperature

Copper Strip Corrosion Tester LRCT-A13

  • 4 piecesSample hole
  • 4 to 12 piecesSample quantity
  • Room temperature to 35 °CAmbient temperature
  • Room temperature to 100°CTemperature controlling range

Rust Characteristics and Corrosion Tester LRCT-A12

  • 4 piecesSample hole
  • Room temperature to 35°CAmbient temperature
  • 0 to 100°CTemperature controlling range
  • ± 1°CTemperature controlling accuracy

Octane Number and Cetane Number Tester LOCT-A10

  • 86.0 to 105.0/MON Measuring Range For Aviation Gasoline
  • National standard: 65.0 to 110.0/RON
    National-V standard: 70 to 115.0/RON
    Blended gasoline: 75.0 to 120.0/RON
    Light gasoline: 50.0 to 85.0 /MON
    Isomerized gasoline: 85.0 to 120.0/RON
    Arene gasoline: 90.0 to 120.0/RON
     Measuring Range For Gasoline For Motor Vehicles
  • E93: 92.0 to 95.0/RON
    E97: 95.0 to 99.0/RON
    Judgement: 60.0 to 120.0/RON
     Measuring Range For Ethanol
  • Cetane number: 25 to 75/CN
    Cetane index: 20 to 80/CI
    Measuring Range For Automobile Diesel Fuels

Portable Octane Number and Cetane Meter LOCT-A20

  • motor gasoline and dieselMeasurement item
  • 40 to 120measurement unit of octane is ON
  • ± 0.5 maxPermissible error of octane
  • ± 0.2 maxFluctuate range of octane
Penetrometer LMPT-A12
  • {"Measurement range":"0 to 600 penetration scale","Timing controller":"5 sec or 60 sec","Time accuracy":"\u00b1 0.1 seconds","Resolution":"0.1 penetration","Penetration accuracy":"\u00b1 1 penetration","Weight of standard needle":"2.5 \u00b1 0.05 g","Dimensions (W \u00d7 L \u00d7 H)":"700 \u00d7 400 \u00d7 750 mm","Weight":"30 kg"}Penetrometer
  • {"Bath volume":"3.5 L","Temperature range":"5 \u00b0C to 60 \u00b0C","Temperature accuracy":"\u00b1 0.1 \u00b0C","Circulatory water quantity":"3 L\/minute","Pump Lift":"2 m","Power consumption":"1200 W","Power supply":"AC 220V \u00b1 10 %, 50 Hz","Dimensions (W \u00d7 L \u00d7 H)":"600 \u00d7 400 \u00d7 650 mm","Weight":"40 kg"}Circulatory Water Bath
Penetrometer LMPT-A11
  • 0 to 600 penetration scaleMeasurement range
  • 5 sec or 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Penetrometer LMPT-A10

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Water Content Tester LWT-A11

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination
Water Content Tester LWT-A10
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination
Coulometric Karl Fischer Titrator LWT-A30
  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed

Lubricating Oil Rust Characteristics Tester LRCT-A11

  • 4 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 1000 ± 50 rpmSpeed for sample stirring
  • Room temperature to 35°CAmbient temperature

Copper Strip Corrosion Tester LRCT-A13

  • 4 piecesSample hole
  • 4 to 12 piecesSample quantity
  • Room temperature to 35 °CAmbient temperature
  • Room temperature to 100°CTemperature controlling range
Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10
  • 2 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 10 to 35°CAmbient temperature
  • Room Temperature to 100°CTemperature controlling range
Rotational Viscometer LRV-A10
  • 10 ~ 2000000 MPa•sViscosity measurement range
  • 5 °C ~ 35 °CAmbient temperature
  • Not more than 80 %Ambient humidity
  • Four spindles of No.1 ~ 4Spindles