Mercaptan Sulfur Tester LMST-A10

Mercaptan Sulfur Tester LMST-A10 determines mercaptan sulfur content present in petroleum products with help of the computer. This detection method is based on principle of Potentiometric titration method. It offers 0 to ±1999.5 Mv potential measuring range and 3 to 100 μg/g (ppm) Mercaptan sulfur measuring range. It ensures the accuracy of the results by titration curve smoothing and titration end position correction. It is used in laboratory, analysis room and petrochemical research departments of the ideal of the necessary device. Mercaptan Sulfur Tester detection method meets the international standard ASTM D3227.

  • Potential measuring range (0 to ±1999.5) Mv
    Intrinsic error 0.1 % ±0.5 mV
    Input impedance Ri ≥1 × 1012 Ω
    Burette capacity 10 mL
    Burette accuracy  ±0.1 % (F•S)
    Titrating time (60±20) s (F•S)
    Mercaptan sulfur measuring range (3 to100) μg/g (ppm)
    Precision r = 0.00007+0.027 X1 [X1 is the mean value of two test results., %( m/m)]
    Ambient temperature 10℃ to 40℃
    Relative humidity ≤ 85 %
     Power consumption 300 W
    Power supply AC 220V±10V, 50Hz ±0.5Hz
    Dimension 260 × 380 × 400 mm (PC is not included)
    Net weight 8 kg (PC is not included)
    • The Sulfur detection method is based on principle of Potentiometric titration method
    • Potential measuring range is from (0 to ±1999.5) Mv
    • Offers real-time display of the titration curve can print and store the titration curve
    • The automatic degree is high and accurate results
    • Automatic cleaning and constant liquid
    • The device can do the all functions automatically
    • Titration apparatus adopts imported key components (Metrohm)
    • Designed with dual high impedance input, the electrode potential stability and reliability
    • Stable and reliable performance, low noise
    • Mercaptan Sulfur Tester detection method meets the international standard ASTM D3227
  • Mercaptan Sulfur Tester is used to automatically determine the end point, without indicator and suitable for a variety of petrochemical products in the light and dark oil basic nitrogen analysis. The titration results and automatic data storage, automatic printing, and can provide a complete analysis of titration data for use.

Automatic Softening Point Tester LSPT-A10

  • 32 ℃ to 160 ℃Measurement range
  • 35 °CAmbient temperature
  • 0.01 ℃Temperature resolution
  • 1000 mLBeaker volume

Acid Number Tester LAAT-A12

  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume
Water Soluble Acid and Alkali Tester LAAT-A10
  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature
Acid Number and Acidity Tester LAAT-A11
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption

Carbon Residue Tester (CONRADSON METHODS) LRCT-B10

  • 30 mlPorcelain crucible
  • 75 mlInner iron crucible
  • 190 mlOuter iron crucible
  • Mig BurnerBurner

Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11

  • Four holes with a furnaceBath type
  • Electric resistance furnaceHeating type
  • 0 ~ 520 °CTemperature controlling range
  • ± 5 °CTemperature controlling accuracy
Carbon Residue Tester (Ramsbottom) LRCT-B20
  • Metal furnaceCoking furnace
  • Electric heatingHeating mode
  • 5 unitsTest unit
  • Ambient to 550°CTemperature range
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Room temperature to 99.9 °CTemperature controlling range
  • ± 1 °CTemperature controlling accuracy

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10

  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 1 s to 9 min 59 sTiming range
  • Room temperature to 99.9 °CTemperature controlling range

Automatic Tag Closed Flash Point Tester LACF-A10

  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity