Penetrometer LMPT-A10

Penetrometer LMPT-A10 is a six grade softening unit for determining needle penetration of bituminous mixture and cone penetration of lubricating grease with control time. It has digital display which shows penetration number of sample. Equipped with grease masher, constant temperature bath, cold light source and a magnifier. Automatic controlled temperature bath for penetration determination. It is ideally used for hydrocarbons mixture, food industries, highway engineering, etc.

  • Measurement range 0 to 600 penetration scale
    Timing controller 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec
    Time accuracy ± 0.1 seconds
    Resolution 0.01 mm
    Penetration accuracy ± 1 penetration
    Temperature control accuracy 25 °C ± 0.1 °C
    Temperature control mode High accuracy digital temperature controller
    Weight of standard needle 2.5 ± 0.05 g
    Weight of standard cone 102.5 ± 0.05 g
    Power consumption 200 W
    Dimensions (L × W × H) 750 × 450 × 750 mm
    Weight 40 kg
    • Digital display shows penetration number of the sample
    • Automatic magnetic stirrer
    • High timing control accuracy
    • Six grade softening control
    • Adjustable needle holder
    • Equipped with grease masher and constant temperature bath
    • Automatic controlled temperature bath
    • Equipped with a cold light source and a magnifier
  • Widely used for determining needle penetration of bituminous mixture, cone penetration of lubricating grease, also for solid particle, powder, colloid mixture, highway engineering and food materials such as glycine, cheese, butter, cream, leavening agents, etc.

  • No. Accessory name
    1 ¼ scale cone

Penetrometer LMPT-A11

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec or 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Penetrometer LMPT-A13

  • 0 to 600 penetration scaleMeasurement range
  • 0 sec to 60 secTiming range
  • ≥ ± 0.1 secondsTime accuracy error
  • 0.1 penetrationResolution

Penetrometer LMPT-A12

  • {"Measurement range":"0 to 600 penetration scale","Timing controller":"5 sec or 60 sec","Time accuracy":"\u00b1 0.1 seconds","Resolution":"0.1 penetration","Penetration accuracy":"\u00b1 1 penetration","Weight of standard needle":"2.5 \u00b1 0.05 g","Dimensions (W \u00d7 L \u00d7 H)":"700 \u00d7 400 \u00d7 750 mm","Weight":"30 kg"}Penetrometer
  • {"Bath volume":"3.5 L","Temperature range":"5 \u00b0C to 60 \u00b0C","Temperature accuracy":"\u00b1 0.1 \u00b0C","Circulatory water quantity":"3 L\/minute","Pump Lift":"2 m","Power consumption":"1200 W","Power supply":"AC 220V \u00b1 10 %, 50 Hz","Dimensions (W \u00d7 L \u00d7 H)":"600 \u00d7 400 \u00d7 650 mm","Weight":"40 kg"}Circulatory Water Bath

Mercaptan Sulfur Tester LMST-A10

  • (0 to ±1999.5) MvPotential measuring range
  • 0.1 % ±0.5 mVIntrinsic error
  • Ri ≥1 × 1012 ΩInput impedance
  • 10 mLBurette capacity

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10

  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 1 s to 9 min 59 sTiming range
  • Room temperature to 99.9 °CTemperature controlling range
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Room temperature to 99.9 °CTemperature controlling range
  • ± 1 °CTemperature controlling accuracy
Insulating Oil Breakdown Voltage Tester LIBT-A23
  • AC 220 V ± 5 % , 50HzPower supply
  • 0 ~ 75 kVMeasurement range
  • 3 kV ± 10 % / sVoltage rising rate
  • 2.5 mmDistance between electrodes

Wax Oil Content Tester LWCT-A22

  • AC 220 V ± 10 %, 50 HzPower supply
  • RT ~ 90 ℃ ± 5 ℃Temperature controlling range in water bath
  • (-35) ℃ ± 1 ℃Cooling bath temperature
  • 35 ℃ ± 1 ℃Evaporation temperature

Mechanical Impurity Tester (Weight Method) LMIT-A21

  • 390 x 260 x 590 mmDimension
  • ≤ 1200 WTotal power consumption
  • AC 220 V ± 10 %, 50 HzPower supply
  • 1000 WHeating power of water bath
Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11
  • Two samples or a group of parallel samplesTest bomb
  • 37.8 °CBath temperature
  • 0.1 °CTemperature controlling accuracy
  • 500 × 560 × 680 mm, 950 × 540 × 720 mmDimensions
Vapor Pressure Tester (REID METHOD) LVPT-C10
  • RT ~ 90 °COperation temperature of water bath
  • ± 0.1 °CTemperature controlling accuracy
  • 550 × 520 × 102 mmDimensions
  • ± 0.4 % kPaPressure meter accuracy

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

  • (-10)℃ ~ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 31.0 ~ 32.0 mmSample cup Inner diameter
  • 1.0 ~ 1.5 mmSample cup Wall thickness

Solidifying Point Tester LLTT-A13

  • ± 0.5 ℃Temperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • Two holes in one trough, and same temperatureCold trough
  • ≤ 30 ℃Ambient temperature
Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15
  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity