Ash Content Tester LACT-A10

Ash Content Tester LACT-A10 is the device composed of muffle furnace, temperature controller and electric heating plate. It is small size and needs less land with special fire-resistant material and heating components. The heating time is short and it has a long lifetime. It used to determine the ash in the range 0.001 to 0.180 mass %, from distillate and petroleum products.

  • Electric Muffle Furnace
    • Controlled temperature: 775 ±25 ℃
    • Temperature rising time of empty chamber: ≤ 50 min
    • Furnace temperature uniformity: ≤ 15℃
    • Internal dimension: 200 × 120 × 80 mm
    • External dimension: 490 × 490 × 450 mm
    • Power consumption: 2.5 kW
    • Power supply: AC 220V ±10%, 50 Hz
    • Net weight: 35 kg
    Temperature controller
    • Maximum control temperature: 1200 ℃
    • Dimension: 500 × 300 × 235 mm
    • Power consumption: 5000 W
    • Power supply: AC 220±10% V, 50Hz
    • Net weight: 5 kg
    Electric heating plate
    • Heating power: (1 to 6) grades, continuously adjustable
    • Temperature: 400℃
    • Diameter of heating plate: Φ 180 mm
    • Dimension: 280 × 250 × 90 mm
    • Power consumption: 2000 W
    • Power supply: AC 220±10%V, 50Hz
    • It is composed of muffle furnace, a temperature controller and electric heating plate
    • Muffle furnace adopts all-in-one structure
    • Equipped with special fire-resistant material and heating components
    • Adjustable LED and designed with temperature controller
    • The overshoot is small and temperature control is stable
    • Material used cold-roll steel sheet of outer shell furnace
    • Good anti-corrosion and long life time
  • Ash Content Tester is used to determine the ash in the range 0.001 to 0.180 mass %, from distillate and residual fuels, gas turbine fuels, crude oils, lubricating oils, waxes, and other petroleum products, in which any ash-forming materials present are normally considered to be undesirable impurities or contaminants.

  • Accessories No. Name Qty
    1 Main unit 1 set
    2 Temperature controller 1 set
    3 Hot plate 1 set
    4 Thermocouple 1 piece
    5 Compensation lead wire 1 piece
    6 Porcelain crucible (50ml) 10 piece
    7 Porcelain crucible (100ml) 10 piece
    8 Crucible tong 1 piece
    9 Fuse 2 piece

Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11

  • Not less than 150 L / hAir flow rate
  • 99 min 59 s (100 min)Max. Preset time
  • Φ22 mmChamber diameter of oven
  • 1400 W × 2Heating power of oven

X-ray Fluorescence Sulfur in Oil Analyzer LST-A10

  • 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)Sample quantity
  • 60, 120, 240, 300, and 600 s at randomMeasurement time
  • 7 ppm to 5 %Measurement range
  • < 0.029 (S + 0.6)Repeatability
Specific Gravity Tester LSGT-A10
  •  4000 ml × 2Vessel Volume
  • 160 WPower of Vacuum pump
  • 3.7 kPa(27.75 mmHg)Negative power
  • 30 WPower of shaking machine
Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11
  • Two samples or a group of parallel samplesTest bomb
  • 37.8 °CBath temperature
  • 0.1 °CTemperature controlling accuracy
  • 500 × 560 × 680 mm, 950 × 540 × 720 mmDimensions

Vapor Pressure Tester (REID METHOD) LVPT-C10

  • RT ~ 90 °COperation temperature of water bath
  • ± 0.1 °CTemperature controlling accuracy
  • 550 × 520 × 102 mmDimensions
  • ± 0.4 % kPaPressure meter accuracy

Automatic Dielectric Tester LADT-A10

  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity
Penetrometer LMPT-A11
  • 0 to 600 penetration scaleMeasurement range
  • 5 sec or 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution
Penetrometer LMPT-A12
  • {"Measurement range":"0 to 600 penetration scale","Timing controller":"5 sec or 60 sec","Time accuracy":"\u00b1 0.1 seconds","Resolution":"0.1 penetration","Penetration accuracy":"\u00b1 1 penetration","Weight of standard needle":"2.5 \u00b1 0.05 g","Dimensions (W \u00d7 L \u00d7 H)":"700 \u00d7 400 \u00d7 750 mm","Weight":"30 kg"}Penetrometer
  • {"Bath volume":"3.5 L","Temperature range":"5 \u00b0C to 60 \u00b0C","Temperature accuracy":"\u00b1 0.1 \u00b0C","Circulatory water quantity":"3 L\/minute","Pump Lift":"2 m","Power consumption":"1200 W","Power supply":"AC 220V \u00b1 10 %, 50 Hz","Dimensions (W \u00d7 L \u00d7 H)":"600 \u00d7 400 \u00d7 650 mm","Weight":"40 kg"}Circulatory Water Bath

Penetrometer LMPT-A10

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution