Ash Content Tester LACT-A10

Ash Content Tester LACT-A10 is the device composed of muffle furnace, temperature controller and electric heating plate. It is small size and needs less land with special fire-resistant material and heating components. The heating time is short and it has a long lifetime. It used to determine the ash in the range 0.001 to 0.180 mass %, from distillate and petroleum products.

  • Electric Muffle Furnace
    • Controlled temperature: 775 ±25 ℃
    • Temperature rising time of empty chamber: ≤ 50 min
    • Furnace temperature uniformity: ≤ 15℃
    • Internal dimension: 200 × 120 × 80 mm
    • External dimension: 490 × 490 × 450 mm
    • Power consumption: 2.5 kW
    • Power supply: AC 220V ±10%, 50 Hz
    • Net weight: 35 kg
    Temperature controller
    • Maximum control temperature: 1200 ℃
    • Dimension: 500 × 300 × 235 mm
    • Power consumption: 5000 W
    • Power supply: AC 220±10% V, 50Hz
    • Net weight: 5 kg
    Electric heating plate
    • Heating power: (1 to 6) grades, continuously adjustable
    • Temperature: 400℃
    • Diameter of heating plate: Φ 180 mm
    • Dimension: 280 × 250 × 90 mm
    • Power consumption: 2000 W
    • Power supply: AC 220±10%V, 50Hz
    • It is composed of muffle furnace, a temperature controller and electric heating plate
    • Muffle furnace adopts all-in-one structure
    • Equipped with special fire-resistant material and heating components
    • Adjustable LED and designed with temperature controller
    • The overshoot is small and temperature control is stable
    • Material used cold-roll steel sheet of outer shell furnace
    • Good anti-corrosion and long life time
  • Ash Content Tester is used to determine the ash in the range 0.001 to 0.180 mass %, from distillate and residual fuels, gas turbine fuels, crude oils, lubricating oils, waxes, and other petroleum products, in which any ash-forming materials present are normally considered to be undesirable impurities or contaminants.

  • Accessories No. Name Qty
    1 Main unit 1 set
    2 Temperature controller 1 set
    3 Hot plate 1 set
    4 Thermocouple 1 piece
    5 Compensation lead wire 1 piece
    6 Porcelain crucible (50ml) 10 piece
    7 Porcelain crucible (100ml) 10 piece
    8 Crucible tong 1 piece
    9 Fuse 2 piece

Automatic Bomb Calorimeter LABC-A11

  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant modeOperation Mode

Automatic Bomb Calorimeter LABC-A10

  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • The outer barrel temperature is constantOperation Mode
Automatic Bomb Calorimeter LABC-B10
  • IsoperibolCalorimeter type
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & loweringOxygen filling
  • 250 mlBomb volume
  • < 8 min full test process: <10 minAnalysis time
Acid Number Tester LAAT-A12
  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume

Acid Number and Acidity Tester LAAT-A11

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption

Water Soluble Acid and Alkali Tester LAAT-A10

  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature
Automatic Distillation Apparatus LADA-A10
  • 2 kWHeating power
  • 0.5 kWCooling power
  • 0 to 400℃Steam temperature
  • 0 to 500℃Oven temperature
Distillation Tester Dual Units LDT-A15
  • 100 mlGraduated flasks
  • 1mlScale division of graduated flask
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature

Benzene Distillation Tester (Low Temperature) LDT-A11

  • -10°C to 35°CAmbient temperature
  • ≤ 85 %Relative humidity
  • Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°CThermometer
  • 0.1 ℃Scale division

Density Tester LDMT-A10

  • Ф300 × 380 mmCubage of bath
  • 0 °C ~ 100 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
  • Industrial platinum resistance, Pt100Temperature sensor
Cleveland Open Cup Flash Point Tester LOFP-A11
  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature
Open Cup Flash Point Tester LOFP-A10
  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity

Automatic COC Flash & Fire Point Tester LOFP-B10

  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability