Acid Number and Acidity Tester LAAT-A11

Labtron LAAT-A11 is designed as per ASTM D664-11a “Test Methods for Acid Number of Petroleum Products” and “Test Methods for Acidity of Gasoline, Kerosene, and Diesel oil”.

  • Graduated flask
    Conical flask
    Separatory funnel
    Volumetric analysis
    Automatic acid titration
    Automatic potential control
    Measurement range
    Potential measurement range
    Burette volume
    Minimum titration volume
    Burette precision
    Precision
    Ambient temperature ≤ 35 °C
    Relative humidity ≤ 85 %
    Temperature compensation
    Preset adjustment range of end point
    Preset controlling range for titration
    Precision of titration tube Scale division is 0.02 ml
    Test tube
    Acidometer Full scale
    Acidometer Accuracy
    Heating power
    Total power consumption ≤ 1200 W
    Power supply AC 220 V ± 10 %, 50 Hz
    Dimension 830 x 290 x 370 mm
    Net weight
    • Heating power can be continuously adjusted
    • Easy installation and operation
    • Compact in size
  • It is used to determine acidity of gasoline, kerosene, and diesel oil, which don’t add ethyl liquids and acid value of petroleum products.

Base Number Tester LAAT-A13

  • Titration condensation: 0.1 N;
    Controlling accuracy: ≤ ± 0.02 ml
    Volumetric analysis
  • Titration condensation: 0.1 N;
    Controlling accuracy: ≤ ± 0.1 pH
    Automatic acid titration
  • Titration condensation: 0.1 N;
    Controlling accuracy: ≤ 10 mV
    Automatic potential control
  • 0 ~ 35 ℃Ambient temperature

Acid Number Tester LAAT-A12

  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume

Water Soluble Acid and Alkali Tester LAAT-A10

  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature

Water Soluble Acid and Alkali Tester LAAT-A10

  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature

Acid Number Tester LAAT-A12

  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume
Acid Number and Acidity Tester LAAT-A11
  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption
Rotational Viscometer LRV-A10
  • 10 ~ 2000000 MPa•sViscosity measurement range
  • 5 °C ~ 35 °CAmbient temperature
  • Not more than 80 %Ambient humidity
  • Four spindles of No.1 ~ 4Spindles

Specific Gravity Tester LSGT-A10

  •  4000 ml × 2Vessel Volume
  • 160 WPower of Vacuum pump
  • 3.7 kPa(27.75 mmHg)Negative power
  • 30 WPower of shaking machine

Transformer Oil Oxidation Stability Tester LOST-D11

  • 6Samples
  • Automatic digital temperatureTemperature controlling mode
  • Room temperature ~ 160 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy
Automatic Lubricating Oils Oxidation Stability Tester LOST-D10
  • 2Samples
  • 30 LOil bath cubage
  • 30 °Angle between bomb and water surface
  • 100 ± 5 RPMSpeed of rotary assembly
Distillate Fuel Oil Oxidation Stability Tester LOST-D12
  • 8Samples
  • 100 ℃Temperature
  • 0.1 ℃Temperature controlling accuracy
  • 3 ± 0.3 L / H oxygenFlow meter

Cleveland Open Cup Flash Point Tester LOFP-A11

  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature

Automatic COC Flash & Fire Point Tester LOFP-B10

  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability
Open Cup Flash Point Tester LOFP-A10
  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity