Automatic COC Flash & Fire Point Tester LOFP-B10

Our LOFP-B10 is deliberately furnished to determine both flash point and fire point. It has a wide range of applications with a great market value. It is designed as per the standard ASTM D92, ISO2592, IP36 (Standard Test Method for Flash Point of Petroleum Products-Cleveland Open Cup Method).

  • Thermometer
    Scale Division
    Spout Aperture
    Ambient Temperature 10 ℃ ~ 40 ℃
    Relative Humidity ≤ 85 %
    Temperature Measurement- Full Scale Ambient temperature to ~ 400 ℃
    Temperature Measurement- Repeatability ≤ 4 ℃
    Temperature Measurement- Reproducibility
    Temperature Measurement- Resolution
    Test accuracy 0.005
    Reappearance ≤ 8 times
    Graduation 0.1 ℃
    Outer Crucible-Material
    Outer Crucible-Diameter Of Upper Opening
    Outer Crucible-Height
    Outer Crucible-Diameter Of Bottom
    Inner Crucible-Material
    Inner Crucible-Diameter Of Upper Opening
    Inner Crucible-Height
    Inner Crucible-Diameter Of Bottom
    Inner Crucible-Scale Line
    Precision
    Gas Tube
    Flame
    Heater
    Heating Power
    Dimensions 620 x 500 x 440 mm
    Power Consumption 400 W
    Power Supply AC 220 V ± 10 %, 50 Hz
    =#REF!
    • Highly precise
    • LCD display
    • Desktop structure and innovative design
    • Fully-automatic
    • Single chip microcomputer technology
    • It have options of presetting the parameters of expected sample mark number, atmospheric pressure and test date
  • It can be widely used in railway, aviation, electric power, petroleum industry and colleges, scientific research institutes, measurement departments to do determination of flash point and fire point for petroleum products except oil fuel and samples whose open cup flash point is below 79 ℃

Automatic Cleveland Open Cup Flash Point Tester LOFP-A12

  • 10 ℃ ~ 40 °CAmbient Temperature
  • ≤ 80 %Relative Humidity
  • Ambient temperature to 300 °CTemperature Measurement- Full Scale
  • ≤ 8 °CTemperature Measurement- Repeatability

Cleveland Open Cup Flash Point Tester LOFP-A11

  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature

Open Cup Flash Point Tester LOFP-A10

  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity

Transformer Oil Oxidation Stability Tester LOST-D11

  • 6Samples
  • Automatic digital temperatureTemperature controlling mode
  • Room temperature ~ 160 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

  • 2Samples
  • 30 LOil bath cubage
  • 30 °Angle between bomb and water surface
  • 100 ± 5 RPMSpeed of rotary assembly
Distillate Fuel Oil Oxidation Stability Tester LOST-D12
  • 8Samples
  • 100 ℃Temperature
  • 0.1 ℃Temperature controlling accuracy
  • 3 ± 0.3 L / H oxygenFlow meter
Penetrometer LMPT-A12
  • {"Measurement range":"0 to 600 penetration scale","Timing controller":"5 sec or 60 sec","Time accuracy":"\u00b1 0.1 seconds","Resolution":"0.1 penetration","Penetration accuracy":"\u00b1 1 penetration","Weight of standard needle":"2.5 \u00b1 0.05 g","Dimensions (W \u00d7 L \u00d7 H)":"700 \u00d7 400 \u00d7 750 mm","Weight":"30 kg"}Penetrometer
  • {"Bath volume":"3.5 L","Temperature range":"5 \u00b0C to 60 \u00b0C","Temperature accuracy":"\u00b1 0.1 \u00b0C","Circulatory water quantity":"3 L\/minute","Pump Lift":"2 m","Power consumption":"1200 W","Power supply":"AC 220V \u00b1 10 %, 50 Hz","Dimensions (W \u00d7 L \u00d7 H)":"600 \u00d7 400 \u00d7 650 mm","Weight":"40 kg"}Circulatory Water Bath

Penetrometer LMPT-A11

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec or 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Penetrometer LMPT-A10

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution
Water Content Tester LWT-A11
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination
Coulometric Karl Fischer Titrator LWT-A30
  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed

Water Content Tester LWT-A10

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination

Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11

  • Four holes with a furnaceBath type
  • Electric resistance furnaceHeating type
  • 0 ~ 520 °CTemperature controlling range
  • ± 5 °CTemperature controlling accuracy
Carbon Residue Tester (Ramsbottom) LRCT-B20
  • Metal furnaceCoking furnace
  • Electric heatingHeating mode
  • 5 unitsTest unit
  • Ambient to 550°CTemperature range
Carbon Residue Tester (CONRADSON METHODS) LRCT-B10
  • 30 mlPorcelain crucible
  • 75 mlInner iron crucible
  • 190 mlOuter iron crucible
  • Mig BurnerBurner

Vapor Pressure Tester (REID METHOD) LVPT-C10

  • RT ~ 90 °COperation temperature of water bath
  • ± 0.1 °CTemperature controlling accuracy
  • 550 × 520 × 102 mmDimensions
  • ± 0.4 % kPaPressure meter accuracy

Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11

  • Two samples or a group of parallel samplesTest bomb
  • 37.8 °CBath temperature
  • 0.1 °CTemperature controlling accuracy
  • 500 × 560 × 680 mm, 950 × 540 × 720 mmDimensions