Penetrometer LMPT-A12

Penetrometer LMPT-A12 is a two grade low temperature controlled unit for determining penetration of pavement petroleum asphalt, modified asphalt, liquid petroleum asphalt and emulsified asphalt with time control. It has digital display which shows penetration number of sample. Separate automatic low temperature circulatory water bath for maintaining constant temperature on the unit. It is ideally used for different types of asphalt, food industries, highway engineering, etc.

  • Penetrometer
    • Measurement range: 0 to 600 penetration scale
    • Timing controller: 5 sec or 60 sec
    • Time accuracy: ± 0.1 seconds
    • Resolution: 0.1 penetration
    • Penetration accuracy: ± 1 penetration
    • Weight of standard needle: 2.5 ± 0.05 g
    • Dimensions (W × L × H): 700 × 400 × 750 mm
    • Weight: 30 kg
    Circulatory Water Bath
    • Bath volume: 3.5 L
    • Temperature range: 5 °C to 60 °C
    • Temperature accuracy: ± 0.1 °C
    • Circulatory water quantity: 3 L/minute
    • Pump Lift: 2 m
    • Power consumption: 1200 W
    • Power supply: AC 220V ± 10 %, 50 Hz
    • Dimensions (W × L × H): 600 × 400 × 650 mm
    • Weight: 40 kg
    • Digital display shows penetration number of the sample
    • Two grade of timing control
    • Adjustable needle holder
    • Designed for low temperature measurement
    • Circulatory water bath maintains constant temperature
    • Low temperature can be preset for different specimens
  • Widely used for determining needle penetration of pavement petroleum asphalt, modified asphalt, liquid petroleum asphalt and emulsified asphalt, also for solid particle, powder, colloid mixture, highway engineering and food materials such as glycine, cheese, butter, cream, leavening agents, etc.

Penetrometer LMPT-A10

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Penetrometer LMPT-A13

  • 0 to 600 penetration scaleMeasurement range
  • 0 sec to 60 secTiming range
  • ≥ ± 0.1 secondsTime accuracy error
  • 0.1 penetrationResolution

Penetrometer LMPT-A11

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec or 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Automatic Dielectric Tester LADT-A10

  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity

Distillation Tester Dual Units LDT-A15

  • 100 mlGraduated flasks
  • 1mlScale division of graduated flask
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature
Automatic Distillation Apparatus LADA-A10
  • 2 kWHeating power
  • 0.5 kWCooling power
  • 0 to 400℃Steam temperature
  • 0 to 500℃Oven temperature
Benzene Distillation Tester (Low Temperature) LDT-A11
  • -10°C to 35°CAmbient temperature
  • ≤ 85 %Relative humidity
  • Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°CThermometer
  • 0.1 ℃Scale division

Octane Number and Cetane Number Tester LOCT-A10

  • 86.0 to 105.0/MON Measuring Range For Aviation Gasoline
  • National standard: 65.0 to 110.0/RON
    National-V standard: 70 to 115.0/RON
    Blended gasoline: 75.0 to 120.0/RON
    Light gasoline: 50.0 to 85.0 /MON
    Isomerized gasoline: 85.0 to 120.0/RON
    Arene gasoline: 90.0 to 120.0/RON
     Measuring Range For Gasoline For Motor Vehicles
  • E93: 92.0 to 95.0/RON
    E97: 95.0 to 99.0/RON
    Judgement: 60.0 to 120.0/RON
     Measuring Range For Ethanol
  • Cetane number: 25 to 75/CN
    Cetane index: 20 to 80/CI
    Measuring Range For Automobile Diesel Fuels

Portable Octane Number and Cetane Meter LOCT-A20

  • motor gasoline and dieselMeasurement item
  • 40 to 120measurement unit of octane is ON
  • ± 0.5 maxPermissible error of octane
  • ± 0.2 maxFluctuate range of octane
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 1 s to 9 min 59 sTiming range
  • Room temperature to 99.9 °CTemperature controlling range
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Room temperature to 99.9 °CTemperature controlling range
  • ± 1 °CTemperature controlling accuracy

Dropping Point Tester (Oil Bath) LDPT-A10

  • 600 mlBeaker quantity
  • (-10) °C ~ 40 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • (-5) °C ~ 300 °CThermometer Measurement range

Dropping Point Tester (Air bath) LDPT-A11

  • ≤ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 250 W × 2Heating power of electric furnace
  • ≤ 700 WTotal power consumption