Penetrometer LMPT-A12

Penetrometer LMPT-A12 is a two grade low temperature controlled unit for determining penetration of pavement petroleum asphalt, modified asphalt, liquid petroleum asphalt and emulsified asphalt with time control. It has digital display which shows penetration number of sample. Separate automatic low temperature circulatory water bath for maintaining constant temperature on the unit. It is ideally used for different types of asphalt, food industries, highway engineering, etc.

  • Penetrometer
    • Measurement range: 0 to 600 penetration scale
    • Timing controller: 5 sec or 60 sec
    • Time accuracy: ± 0.1 seconds
    • Resolution: 0.1 penetration
    • Penetration accuracy: ± 1 penetration
    • Weight of standard needle: 2.5 ± 0.05 g
    • Dimensions (W × L × H): 700 × 400 × 750 mm
    • Weight: 30 kg
    Circulatory Water Bath
    • Bath volume: 3.5 L
    • Temperature range: 5 °C to 60 °C
    • Temperature accuracy: ± 0.1 °C
    • Circulatory water quantity: 3 L/minute
    • Pump Lift: 2 m
    • Power consumption: 1200 W
    • Power supply: AC 220V ± 10 %, 50 Hz
    • Dimensions (W × L × H): 600 × 400 × 650 mm
    • Weight: 40 kg
    • Digital display shows penetration number of the sample
    • Two grade of timing control
    • Adjustable needle holder
    • Designed for low temperature measurement
    • Circulatory water bath maintains constant temperature
    • Low temperature can be preset for different specimens
  • Widely used for determining needle penetration of pavement petroleum asphalt, modified asphalt, liquid petroleum asphalt and emulsified asphalt, also for solid particle, powder, colloid mixture, highway engineering and food materials such as glycine, cheese, butter, cream, leavening agents, etc.

Penetrometer LMPT-A11

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec or 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Penetrometer LMPT-A13

  • 0 to 600 penetration scaleMeasurement range
  • 0 sec to 60 secTiming range
  • ≥ ± 0.1 secondsTime accuracy error
  • 0.1 penetrationResolution

Penetrometer LMPT-A10

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Engler Viscometer LEV-B10

  • 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)Graduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • 10 °C ~ 40 °CAmbient Temperature

Engler Viscometer LEV-A10

  • 200 ± 0.2 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.2 °CTemperature Controlling Accuracy
Engler Viscometer LEV-A11
  • 100 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.1 °CTemperature Controlling Accuracy
Kinematics Viscometer LKV-A12
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A13

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A11

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Specific Gravity Tester LSGT-A10
  •  4000 ml × 2Vessel Volume
  • 160 WPower of Vacuum pump
  • 3.7 kPa(27.75 mmHg)Negative power
  • 30 WPower of shaking machine
Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10
  • 2 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 10 to 35°CAmbient temperature
  • Room Temperature to 100°CTemperature controlling range

Lubricating Oil Rust Characteristics Tester LRCT-A11

  • 4 piecesSample hole
  • 1400 rpmSpeed of stirring motor
  • 1000 ± 50 rpmSpeed for sample stirring
  • Room temperature to 35°CAmbient temperature

Copper Strip Corrosion Tester LRCT-A13

  • 4 piecesSample hole
  • 4 to 12 piecesSample quantity
  • Room temperature to 35 °CAmbient temperature
  • Room temperature to 100°CTemperature controlling range
Automatic Tag Closed Flash Point Tester LACF-A10
  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity