Engler Viscometer LEV-B10

LEV-B10 Engler Viscometer guarantees compliance with ASTM D1665 “Test Methods for Engler Viscosity of Petroleum Products” for determining kinetic viscosities of tars and their fluid products from ambient temperature to 100ºC (212ºF). It is designed and made as per “Asphalt Engler Viscosity Test (Engler Viscometer Methods)”.

  • Graduated Flask 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
    Standard Water Value 51 ± 1 s
    Temperature Range 0 ~ 100 °C
    Ambient Temperature 10 °C ~ 40 °C
    Temperature Controlling Accuracy ± 0.1 °C
    Relative Humidity ≤ 85 %
    Timer Max is 9999 s
    Accuracy Of Timer
    Heating Power 700 W
    Dimension 630 x 490 x 760 mm
    Power Of Heater
    Total Power Consumption ≤ 800 W
    Power Supply AC 220 V ± 10 %, 50 Hz
    =#REF!
    • Stainless steel Inner container
    • Simultaneous determination of two samples
    • High Temperature control Accuracy
  • It is extensively used for pharmaceutics, petroleum, chemical, scientific research etc.

Engler Viscometer LEV-A10

  • 200 ± 0.2 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.2 °CTemperature Controlling Accuracy

Engler Viscometer LEV-A11

  • 100 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.1 °CTemperature Controlling Accuracy

Coulometric Karl Fischer Titrator LWT-A30

  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed

Water Content Tester LWT-A11

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination
Water Content Tester LWT-A10
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 1 s to 9 min 59 sTiming range
  • Room temperature to 99.9 °CTemperature controlling range

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11

  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Room temperature to 99.9 °CTemperature controlling range
  • ± 1 °CTemperature controlling accuracy

Acid Number and Acidity Tester LAAT-A11

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption
Acid Number Tester LAAT-A12
  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume
Water Soluble Acid and Alkali Tester LAAT-A10
  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature

Transformer Oil Oxidation Stability Tester LOST-D11

  • 6Samples
  • Automatic digital temperatureTemperature controlling mode
  • Room temperature ~ 160 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy

Distillate Fuel Oil Oxidation Stability Tester LOST-D12

  • 8Samples
  • 100 ℃Temperature
  • 0.1 ℃Temperature controlling accuracy
  • 3 ± 0.3 L / H oxygenFlow meter
Automatic Lubricating Oils Oxidation Stability Tester LOST-D10
  • 2Samples
  • 30 LOil bath cubage
  • 30 °Angle between bomb and water surface
  • 100 ± 5 RPMSpeed of rotary assembly
Automatic Dielectric Tester LADT-A10
  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity