Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12 is automated and controlled by microprocessor unit. It offers 0 to 1800.0 mV potential measurement range and ≥0.05 mg KOH/g acid number measurement range. It works on potentiometric titration principle. Recording the titration of the electrode potential and the titration volume, find out the equivalence point and corresponding titrant volume, and thus obtained the sample pH value. This unit can accurately detect the acid value of transformer oil, turbine oil, anti-oil, diesel, gasoline and other petroleum products. It offers Standard Determination of acid number, Determination of acid number in transformer and turbine oils in service (BTB), ASTM D664-2011).

  • Graduated flask
    Conical flask
    Separatory funnel
    Volumetric analysis
    Automatic acid titration
    Automatic potential control
    Measurement range ≥0.05 mg KOH/g
    Potential measurement range 0 to 1800.0 mV
    Burette volume 10 mL
    Minimum titration volume 0.001 ml
    Burette precision ±0.1 %FS
    Precision Fit or above the relative standards
    Ambient temperature 5℃ to 35℃
    Relative humidity Less 80 %
    Temperature compensation
    Preset adjustment range of end point
    Preset controlling range for titration
    Precision of titration tube
    Test tube
    Acidometer Full scale
    Acidometer Accuracy
    Heating power
    Total power consumption
    Power supply AC (220±11)V , 50±1 Hz
    Dimension About 350 × 280 ×178 mm
    Net weight Main unit 14 kg
    • Equipped with windows operating platform, with the computer directly
    • Designed with titration curve real-time display, titration curve and data storage and printing
    • Imported titration unit and measuring accuracy better stability
    • Automatic cleaning, automatic constant liquid
    • Offers automatic detection of end points, automatic filtering false end, at the same time can determine the endpoint of artificial selection
    • Designed with continued dosing function
    • It is easy to operate and adopts workstation
  • Acid Number Tester used in chemical industry, electric power, oil and other industries, it is ideal products to current meter acid number of petroleum products.

  • Accessories no.NameQty.
    1Magnetic Agitator1 pcs
    2Agitator Strut1 pcs
    3Electrode holder1 pcs
    4Magnetic rotor4 pcs
    5RS232 serial communication line1 pcs
    6Short-circuit plug2 pcs
    7Fuse (2A)2 pcs
    8231 glass pH electrode2 pcs
    9802 saturated calomel electrode 2 pcs
    10Titration exchange unit (10mL)1 pcs
    11Agitator stabilized voltage supply (5V)1 pcs
    125ml(or 10ml) syringe1 pcs
    13Special size 9 injection needle1 pcs

Acid Number and Acidity Tester LAAT-A11

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption

Base Number Tester LAAT-A13

  • Titration condensation: 0.1 N;
    Controlling accuracy: ≤ ± 0.02 ml
    Volumetric analysis
  • Titration condensation: 0.1 N;
    Controlling accuracy: ≤ ± 0.1 pH
    Automatic acid titration
  • Titration condensation: 0.1 N;
    Controlling accuracy: ≤ 10 mV
    Automatic potential control
  • 0 ~ 35 ℃Ambient temperature

Water Soluble Acid and Alkali Tester LAAT-A10

  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature

Transformer Oil Oxidation Stability Tester LOST-D11

  • 6Samples
  • Automatic digital temperatureTemperature controlling mode
  • Room temperature ~ 160 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

  • 2Samples
  • 30 LOil bath cubage
  • 30 °Angle between bomb and water surface
  • 100 ± 5 RPMSpeed of rotary assembly
Distillate Fuel Oil Oxidation Stability Tester LOST-D12
  • 8Samples
  • 100 ℃Temperature
  • 0.1 ℃Temperature controlling accuracy
  • 3 ± 0.3 L / H oxygenFlow meter
Specific Gravity Tester LSGT-A10
  •  4000 ml × 2Vessel Volume
  • 160 WPower of Vacuum pump
  • 3.7 kPa(27.75 mmHg)Negative power
  • 30 WPower of shaking machine

Automatic Dielectric Tester LADT-A10

  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity

Carbon Residue Tester (CONRADSON METHODS) LRCT-B10

  • 30 mlPorcelain crucible
  • 75 mlInner iron crucible
  • 190 mlOuter iron crucible
  • Mig BurnerBurner
Carbon Residue Tester (Ramsbottom) LRCT-B20
  • Metal furnaceCoking furnace
  • Electric heatingHeating mode
  • 5 unitsTest unit
  • Ambient to 550°CTemperature range
Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11
  • Four holes with a furnaceBath type
  • Electric resistance furnaceHeating type
  • 0 ~ 520 °CTemperature controlling range
  • ± 5 °CTemperature controlling accuracy

Oxygen Bomb Calorimeter LBC-C21

  • 10 ℃ ~ 35 ℃Temperature controlling range
  • 0.001 ℃Temperature resolution
  • 15 kJ / KMean value of heat capacity
  • 20 ℃ ± 5 ℃Ambient temperature

Oxygen Bomb Calorimeter LBC-C20

  • 14000 ~ 15000 J / KHeat capacity
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
Oxygen Bomb Calorimeter LBC-C22
  • 10 ~ 35 ℃Temperature measurement range
  • ≤ 0.2 % (Grade C)Repeatability error
  • 20 MPaEndured pressure in oxygen bomb
  • 15 ~ 28 ℃Operation environment temperature