Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12 is automated and controlled by microprocessor unit. It offers 0 to 1800.0 mV potential measurement range and ≥0.05 mg KOH/g acid number measurement range. It works on potentiometric titration principle. Recording the titration of the electrode potential and the titration volume, find out the equivalence point and corresponding titrant volume, and thus obtained the sample pH value. This unit can accurately detect the acid value of transformer oil, turbine oil, anti-oil, diesel, gasoline and other petroleum products. It offers Standard Determination of acid number, Determination of acid number in transformer and turbine oils in service (BTB), ASTM D664-2011).

  • Graduated flask
    Conical flask
    Separatory funnel
    Volumetric analysis
    Automatic acid titration
    Automatic potential control
    Measurement range ≥0.05 mg KOH/g
    Potential measurement range 0 to 1800.0 mV
    Burette volume 10 mL
    Minimum titration volume 0.001 ml
    Burette precision ±0.1 %FS
    Precision Fit or above the relative standards
    Ambient temperature 5℃ to 35℃
    Relative humidity Less 80 %
    Temperature compensation
    Preset adjustment range of end point
    Preset controlling range for titration
    Precision of titration tube
    Test tube
    Acidometer Full scale
    Acidometer Accuracy
    Heating power
    Total power consumption
    Power supply AC (220±11)V , 50±1 Hz
    Dimension About 350 × 280 ×178 mm
    Net weight Main unit 14 kg
    • Equipped with windows operating platform, with the computer directly
    • Designed with titration curve real-time display, titration curve and data storage and printing
    • Imported titration unit and measuring accuracy better stability
    • Automatic cleaning, automatic constant liquid
    • Offers automatic detection of end points, automatic filtering false end, at the same time can determine the endpoint of artificial selection
    • Designed with continued dosing function
    • It is easy to operate and adopts workstation
  • Acid Number Tester used in chemical industry, electric power, oil and other industries, it is ideal products to current meter acid number of petroleum products.

  • Accessories no.NameQty.
    1Magnetic Agitator1 pcs
    2Agitator Strut1 pcs
    3Electrode holder1 pcs
    4Magnetic rotor4 pcs
    5RS232 serial communication line1 pcs
    6Short-circuit plug2 pcs
    7Fuse (2A)2 pcs
    8231 glass pH electrode2 pcs
    9802 saturated calomel electrode 2 pcs
    10Titration exchange unit (10mL)1 pcs
    11Agitator stabilized voltage supply (5V)1 pcs
    125ml(or 10ml) syringe1 pcs
    13Special size 9 injection needle1 pcs

Base Number Tester LAAT-A13

  • Titration condensation: 0.1 N;
    Controlling accuracy: ≤ ± 0.02 ml
    Volumetric analysis
  • Titration condensation: 0.1 N;
    Controlling accuracy: ≤ ± 0.1 pH
    Automatic acid titration
  • Titration condensation: 0.1 N;
    Controlling accuracy: ≤ 10 mV
    Automatic potential control
  • 0 ~ 35 ℃Ambient temperature

Acid Number and Acidity Tester LAAT-A11

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption

Water Soluble Acid and Alkali Tester LAAT-A10

  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature

Automatic Tag Closed Flash Point Tester LACF-A10

  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity

Automatic Bomb Calorimeter LABC-A11

  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant modeOperation Mode
Automatic Bomb Calorimeter LABC-B10
  • IsoperibolCalorimeter type
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & loweringOxygen filling
  • 250 mlBomb volume
  • < 8 min full test process: <10 minAnalysis time
Automatic Bomb Calorimeter LABC-A10
  • IsoperibolCalorimeter type
  • 5 to 40°CTemperature range
  • 5 to 40 MJ/ kgMeasurement range
  • The outer barrel temperature is constantOperation Mode

Mechanical Impurity Tester (Weight Method) LMIT-A21

  • 390 x 260 x 590 mmDimension
  • ≤ 1200 WTotal power consumption
  • AC 220 V ± 10 %, 50 HzPower supply
  • 1000 WHeating power of water bath

Wax Oil Content Tester LWCT-A22

  • AC 220 V ± 10 %, 50 HzPower supply
  • RT ~ 90 ℃ ± 5 ℃Temperature controlling range in water bath
  • (-35) ℃ ± 1 ℃Cooling bath temperature
  • 35 ℃ ± 1 ℃Evaporation temperature
Insulating Oil Breakdown Voltage Tester LIBT-A23
  • AC 220 V ± 5 % , 50HzPower supply
  • 0 ~ 75 kVMeasurement range
  • 3 kV ± 10 % / sVoltage rising rate
  • 2.5 mmDistance between electrodes
Existent Gum Tester LEGT- B31
  • Aluminum block bath, φ260 × 130 mmEvaporation bath type and size
  • 3 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • Flow meterFlow rate display

Existent Gum Tester LEGT- B30

  • Oil bathBath type
  • 5000 ml ± 50 mlBath capacity
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity

Existent Gum Tester LEGT- B32

  • Aluminum bath φ260 × 130 mmEvaporation bath type and size
  • 5 piecesHoles for testing
  • φ51 × 70 mmSize of holes for testing cylinder
  • 160 ℃ ~ 165℃Working temperature
Aniline Point Tester LAPT-A10
  • Room temperature ~ 150°CMeasurement range
  • 0 ~ 1200 r / minStirring speed
  • 25 WHeating power
  • 360 × 250 × 545 mmInterior Dimension
Aniline Point Tester LAPT-A11
  • ≤ 0.5 ℃Temperature controlling accuracy
  • Room temperature ~ 200 ℃Temperature controlling range
  • 5 VPower supply for illumination
  • 2 kWPower of motor