Kinematics Viscometer LKV-A11

Labtron LKV-A11 Kinematic Viscometer is used for precise measurement with capillary viscometers. It is made according to “Test Methods for Kinematic Viscosity of Petroleum Products and Calculation of Dynamic Viscosity” as per ASTM D445.

  • Ambient temperature (-10) °C ~ 35 °C
    Relative humidity ≤ 85 %
    Capillary viscometer 11 pieces
    Stirring motor 6 W, 1200 rpm
    Sample quantity
    Bath temperature
    Measurement range
    Bath cubage
    Temperature controlling range
    Temperature controlling accuracy ± 0.1 °C
    Illumination
    Constant temperature bath 20 L; two layers water bath
    Timing range
    Barometric
    Timing accuracy
    Timing device
    Temperature sensor Industrial platinum resistance; Pt100
    Inner capillary viscometer diameters 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5 and 4.0 mm respectively (inner diameters of 5.0 and 6.0mm are optional)
    Mercury thermometer scale division
    • LCD temperature controller
    • High Temperature control accuracy which can reach ± 0.1 ℃
    • Uniform water bath temperature
    • Electric stirring device
    • Convenient to operate and gives fast response
  • It is used in the fields of petroleum & its products industries, research and development department.

Kinematics Viscometer LKV-A15

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Low Temperature Kinematic Viscosity Tester LKV-A14

  • ≤ 30 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 13 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A16

  • 0 ~ 40 ºCAmbient temperature
  • 20 ~ 90 %, RH while 40 ℃Relative humidity
  • ± 0.1 °CTemperature controlling accuracy
  • 0.0 s ~ 9999.9 sTiming range
Kinematics Viscometer LKV-A10
  • 15 to 35°CAmbient temperature
  • ≤ 85%Relative humidity
  • 6 capillary Pinkevitch viscometer tubesCapillary viscometer
  • 1200 rpmStirring motor
Kinematics Viscometer LKV-A13
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A12

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Mercaptan Sulfur Tester LMST-A10

  • (0 to ±1999.5) MvPotential measuring range
  • 0.1 % ±0.5 mVIntrinsic error
  • Ri ≥1 × 1012 ΩInput impedance
  • 10 mLBurette capacity

Automatic Dielectric Tester LADT-A10

  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity
Octane Number and Cetane Number Tester LOCT-A10
  • 86.0 to 105.0/MON Measuring Range For Aviation Gasoline
  • National standard: 65.0 to 110.0/RON
    National-V standard: 70 to 115.0/RON
    Blended gasoline: 75.0 to 120.0/RON
    Light gasoline: 50.0 to 85.0 /MON
    Isomerized gasoline: 85.0 to 120.0/RON
    Arene gasoline: 90.0 to 120.0/RON
     Measuring Range For Gasoline For Motor Vehicles
  • E93: 92.0 to 95.0/RON
    E97: 95.0 to 99.0/RON
    Judgement: 60.0 to 120.0/RON
     Measuring Range For Ethanol
  • Cetane number: 25 to 75/CN
    Cetane index: 20 to 80/CI
    Measuring Range For Automobile Diesel Fuels
Portable Octane Number and Cetane Meter LOCT-A20
  • motor gasoline and dieselMeasurement item
  • 40 to 120measurement unit of octane is ON
  • ± 0.5 maxPermissible error of octane
  • ± 0.2 maxFluctuate range of octane

Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11

  • Two samples or a group of parallel samplesTest bomb
  • 37.8 °CBath temperature
  • 0.1 °CTemperature controlling accuracy
  • 500 × 560 × 680 mm, 950 × 540 × 720 mmDimensions

Vapor Pressure Tester (REID METHOD) LVPT-C10

  • RT ~ 90 °COperation temperature of water bath
  • ± 0.1 °CTemperature controlling accuracy
  • 550 × 520 × 102 mmDimensions
  • ± 0.4 % kPaPressure meter accuracy
Automatic COC Flash & Fire Point Tester LOFP-B10
  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability
Cleveland Open Cup Flash Point Tester LOFP-A11
  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature

Open Cup Flash Point Tester LOFP-A10

  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity