Kinematics Viscometer LKV-A15

Labtron LKV-A15 is fully automated kinematic viscometer, designed with single chip microcomputer and Industrial Platinum Temperature Sensor. It is accorded as per ASTM D445 “Test Methods for Kinematic Viscosity of Petroleum Products and Calculation of Dynamic Viscosity”.

  • Ambient temperature (-10) °C ~ 35 °C
    Relative humidity ≤ 85 %
    Capillary viscometer 11 pieces
    Stirring motor 6 W, 1200 rpm
    Sample quantity 4 piece at the same time
    Bath temperature
    Measurement range Ambient Temperature ~ 100.0 °C
    Bath cubage 20 L
    Temperature controlling range
    Temperature controlling accuracy ± 0.1 °C
    Illumination
    Constant temperature bath
    Timing range 0.0 s ~ 9999.9 s
    Barometric
    Timing accuracy ≤ ± 0.05 % in 60 min
    Timing device
    Temperature sensor
    Inner capillary viscometer diameters 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5, and 4.0 mm
    Mercury thermometer scale division
    • Industrial Platinum Temperature Sensor
    • Fully automatic
    • Robotically saves the parameters of capillary tube diameter and coefficient
    • Colored LCD technology
  • It is used in the fields of petroleum & its products industries, research and development department.

Kinematics Viscometer LKV-A13

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Kinematics Viscometer LKV-A12

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Low Temperature Kinematic Viscosity Tester LKV-A14

  • ≤ 30 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 13 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A11
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A16
  • 0 ~ 40 ºCAmbient temperature
  • 20 ~ 90 %, RH while 40 ℃Relative humidity
  • ± 0.1 °CTemperature controlling accuracy
  • 0.0 s ~ 9999.9 sTiming range

Kinematics Viscometer LKV-A10

  • 15 to 35°CAmbient temperature
  • ≤ 85%Relative humidity
  • 6 capillary Pinkevitch viscometer tubesCapillary viscometer
  • 1200 rpmStirring motor

Dropping Point Tester (Air bath) LDPT-A11

  • ≤ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 250 W × 2Heating power of electric furnace
  • ≤ 700 WTotal power consumption

Dropping Point Tester (Oil Bath) LDPT-A10

  • 600 mlBeaker quantity
  • (-10) °C ~ 40 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • (-5) °C ~ 300 °CThermometer Measurement range
Automatic Dielectric Tester LADT-A10
  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity
Automatic PMCC Flash Point Tester LCFP-A13
  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range

PMCC Flash Point Tester LCFP-A10

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device

Automatic PMCC Flash Point Tester LCFP-A11

  • 10 °C ~ 40 °CAmbient temperature
  • ≤ 80 %Relative humidity
  • Ambient Temperature ~ 250 °CMeasurement Range
  • Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °CFlash Point
Automatic Tag Closed Flash Point Tester LACF-A10
  • -50 to 70°CExperimental temperature range
  • 50 mlTest sample volume
  • 10 to 40°CAmbient temperature range
  • ≤ 85%Humidity
Water Content Tester LWT-A11
  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination

Water Content Tester LWT-A10

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination

Coulometric Karl Fischer Titrator LWT-A30

  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed