Automatic PMCC Flash Point Tester LCFP-A11

Labtron model LCFP-A11 is an automated closed cup flash point tester with automatic control measurement procedures and test data. It is designed as per ASTM D93 “Test Methods for Flash Point of Petroleum Products (Closed Cup Methods)”.

  • Ambient temperature 10 °C ~ 40 °C
    Relative humidity ≤ 80 %
    Ignition Mode
    Temperature range
    Aperture of ignition device
    Standard oil cup-Inner diameter
    Standard oil cup- Depth
    Standard oil cup- Depth of Marked line on the oil cup
    Standard oil cup-Oil sample cubage
    Stirring speed
    Stirring blade
    Sample temperature rising rate
    Measurement Range Ambient Temperature ~ 250 °C
    Flash Point Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C
    Resolution 0.1 °C
    Repeatability
    Reproducibility
    Accuracy
    Precision 0.005
    Gas Flame 3 ~ 4 mm
    Heating power
    Dimension 550 × 470 × 500 mm
    Total Power Consumption 350 W
    Power supply AC 220 V ± 10 %, 50 Hz
    Net Weight
    • Revised value calculation
    • Measurement procedures and test data has programmed function
    • Gas flame ignition mode
    • Atmospheric pressure is modified automatically along with temperature control
    • Measurement procedures and test data has automatic function
    • Results are analyzed and saved automatically
  • It is suitable to determine closed cup flash point of petroleum products having a flash point higher than 40 °C

Automatic PMCC Flash Point Tester LCFP-A13

  • 10 °C ~ 40 ℃Ambient temperature
  • ≤ 80 %Relative humidity
  • electron igniter / gas flameIgnition Mode
  • Room Temperature ~ 300 ℃Temperature range

PMCC Flash Point Tester LCFP-A10

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °CTemperature range
  • 0.8 mmAperture of ignition device

Constant Temperature Needle Penetration Tester LTNP-A10

  • 0 to 700 taper degree (digital display table 0-70 mm)Measuring range
  • Timing error is less than ±0.1 sTiming device
  • 0.01 mm Resolution
  • ±1 cone insertion degreeNeedle insertion accuracy

Cleveland Open Cup Flash Point Tester LOFP-A11

  • 6 ℃ ~ 400 ℃Thermometer
  • 2 °CScale Division
  • 0.6 ~ 0.8 mmSpout Aperture
  • -10 ℃ ~ 50 ℃Ambient Temperature
Automatic COC Flash & Fire Point Tester LOFP-B10
  • 10 ℃ ~ 40 ℃Ambient Temperature
  • ≤ 85 %Relative Humidity
  • Ambient temperature to ~ 400 ℃Temperature Measurement- Full Scale
  • ≤ 4 ℃Temperature Measurement- Repeatability
Open Cup Flash Point Tester LOFP-A10
  • 0 ℃ ~ 360 °CThermometer
  • 1 °CScale Division
  • ≤ 35 °CAmbient Temperature
  • ≤ 85 %Relative Humidity

Automatic Dielectric Tester LADT-A10

  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity

Portable Octane Number and Cetane Meter LOCT-A20

  • motor gasoline and dieselMeasurement item
  • 40 to 120measurement unit of octane is ON
  • ± 0.5 maxPermissible error of octane
  • ± 0.2 maxFluctuate range of octane
Octane Number and Cetane Number Tester LOCT-A10
  • 86.0 to 105.0/MON Measuring Range For Aviation Gasoline
  • National standard: 65.0 to 110.0/RON
    National-V standard: 70 to 115.0/RON
    Blended gasoline: 75.0 to 120.0/RON
    Light gasoline: 50.0 to 85.0 /MON
    Isomerized gasoline: 85.0 to 120.0/RON
    Arene gasoline: 90.0 to 120.0/RON
     Measuring Range For Gasoline For Motor Vehicles
  • E93: 92.0 to 95.0/RON
    E97: 95.0 to 99.0/RON
    Judgement: 60.0 to 120.0/RON
     Measuring Range For Ethanol
  • Cetane number: 25 to 75/CN
    Cetane index: 20 to 80/CI
    Measuring Range For Automobile Diesel Fuels
Mercaptan Sulfur Tester LMST-A10
  • (0 to ±1999.5) MvPotential measuring range
  • 0.1 % ±0.5 mVIntrinsic error
  • Ri ≥1 × 1012 ΩInput impedance
  • 10 mLBurette capacity