Mechanical Impurity Tester (Weight Method) LMIT-A21

Labtron LMIT-A21 Mechanical Impurity Tester is manufactured with digital temperature controller and motor. The instrument is designed as per “Test Methods for Mechanical Impurity in Petroleum Products and Additive (Weight Methods). We meticulously designed it for accuracy and efficiency.

  • Light source
    Temperature of grinding milk white light bulb
    Light hole( Φ14)
    Color comparing tube
    Dimension 390 x 260 x 590 mm
    Non-colorful flat bottom glass tube
    Observation lens
    Total power consumption ≤ 1200 W
    Power supply AC 220 V ± 10 %, 50 Hz
    Heating power of water bath 1000 W
    Relative humidity ≤ 85 %
    Ambient temperature ≤ 35 °C
    Temperature display mode of water bath Digitally displayed by a LED
    Temperature controlling range in water bath RT to 90 °C
    Temperature controlling accuracy in water bath: ± 1 °C
    Temperature controlling range in funnel RT to 90 °C
    Temperature display mode of funnel Digitally displayed by a LED
    Temperature controlling accuracy in funnel ± 2 °C
    Controlling case (L × W × H) 390 × 260 × 590 mm
    Water bath (L × W × H) 90 × 290 × 370 mm
    Cooling bath temperature
    Evaporation temperature
    Flow rate
    Timing range of timer
    Measurement range
    Voltage rising rate
    Distance between electrodes
    Output power
    • Advantage of glass vessels, water bath, funnel, suction pump, motor and digital temperature controller.
    • Small size, rapid heating rate and easy installation
    • Save operation time and solvent
    • Desktop structure
  • It is mainly used in petroleum, chemical, research and development industry.

Color Tester LCT-A20

  • 220 V, 100 WLight source
  • 2750 ± 50 KTemperature of grinding milk white light bulb
  • 26 piecesLight hole( Φ14)
  • Φ32 mmColor comparing tube

Wax Oil Content Tester LWCT-A22

  • AC 220 V ± 10 %, 50 HzPower supply
  • RT ~ 90 ℃ ± 5 ℃Temperature controlling range in water bath
  • (-35) ℃ ± 1 ℃Cooling bath temperature
  • 35 ℃ ± 1 ℃Evaporation temperature

Insulating Oil Breakdown Voltage Tester LIBT-A23

  • AC 220 V ± 5 % , 50HzPower supply
  • 0 ~ 75 kVMeasurement range
  • 3 kV ± 10 % / sVoltage rising rate
  • 2.5 mmDistance between electrodes

Acid Number Tester LAAT-A12

  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume

Acid Number and Acidity Tester LAAT-A11

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption
Water Soluble Acid and Alkali Tester LAAT-A10
  • 100 ml,50 mlGraduated flask
  • 100mlConical flask
  • 250mlSeparatory funnel
  • (-10 )°C to 35 °CAmbient temperature
Penetrometer LMPT-A12
  • {"Measurement range":"0 to 600 penetration scale","Timing controller":"5 sec or 60 sec","Time accuracy":"\u00b1 0.1 seconds","Resolution":"0.1 penetration","Penetration accuracy":"\u00b1 1 penetration","Weight of standard needle":"2.5 \u00b1 0.05 g","Dimensions (W \u00d7 L \u00d7 H)":"700 \u00d7 400 \u00d7 750 mm","Weight":"30 kg"}Penetrometer
  • {"Bath volume":"3.5 L","Temperature range":"5 \u00b0C to 60 \u00b0C","Temperature accuracy":"\u00b1 0.1 \u00b0C","Circulatory water quantity":"3 L\/minute","Pump Lift":"2 m","Power consumption":"1200 W","Power supply":"AC 220V \u00b1 10 %, 50 Hz","Dimensions (W \u00d7 L \u00d7 H)":"600 \u00d7 400 \u00d7 650 mm","Weight":"40 kg"}Circulatory Water Bath

Penetrometer LMPT-A11

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec or 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution

Penetrometer LMPT-A10

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution
Engler Viscometer LEV-B10
  • 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)Graduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • 10 °C ~ 40 °CAmbient Temperature
Engler Viscometer LEV-A11
  • 100 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.1 °CTemperature Controlling Accuracy

Engler Viscometer LEV-A10

  • 200 ± 0.2 mlGraduated Flask
  • 51 ± 1 sStandard Water Value
  • 0 ~ 100 °CTemperature Range
  • ± 0.2 °CTemperature Controlling Accuracy

Automatic Dielectric Tester LADT-A10

  • 2.0 kVACapacity
  • 2 k V/ sSpeed of voltage increase
  • 0.01Voltage inspection accuracy
  • < 0.1 kVBreakdown sensitivity
Specific Gravity Tester LSGT-A10
  •  4000 ml × 2Vessel Volume
  • 160 WPower of Vacuum pump
  • 3.7 kPa(27.75 mmHg)Negative power
  • 30 WPower of shaking machine