Mechanical Impurity Tester (Weight Method) LMIT-A21

Labtron LMIT-A21 Mechanical Impurity Tester is manufactured with digital temperature controller and motor. The instrument is designed as per “Test Methods for Mechanical Impurity in Petroleum Products and Additive (Weight Methods). We meticulously designed it for accuracy and efficiency.

  • Light source
    Temperature of grinding milk white light bulb
    Light hole( Φ14)
    Color comparing tube
    Dimension 390 x 260 x 590 mm
    Non-colorful flat bottom glass tube
    Observation lens
    Total power consumption ≤ 1200 W
    Power supply AC 220 V ± 10 %, 50 Hz
    Heating power of water bath 1000 W
    Relative humidity ≤ 85 %
    Ambient temperature ≤ 35 °C
    Temperature display mode of water bath Digitally displayed by a LED
    Temperature controlling range in water bath RT to 90 °C
    Temperature controlling accuracy in water bath: ± 1 °C
    Temperature controlling range in funnel RT to 90 °C
    Temperature display mode of funnel Digitally displayed by a LED
    Temperature controlling accuracy in funnel ± 2 °C
    Controlling case (L × W × H) 390 × 260 × 590 mm
    Water bath (L × W × H) 90 × 290 × 370 mm
    Cooling bath temperature
    Evaporation temperature
    Flow rate
    Timing range of timer
    Measurement range
    Voltage rising rate
    Distance between electrodes
    Output power
    • Advantage of glass vessels, water bath, funnel, suction pump, motor and digital temperature controller.
    • Small size, rapid heating rate and easy installation
    • Save operation time and solvent
    • Desktop structure
  • It is mainly used in petroleum, chemical, research and development industry.

Insulating Oil Breakdown Voltage Tester LIBT-A23

  • AC 220 V ± 5 % , 50HzPower supply
  • 0 ~ 75 kVMeasurement range
  • 3 kV ± 10 % / sVoltage rising rate
  • 2.5 mmDistance between electrodes

Color Tester LCT-A20

  • 220 V, 100 WLight source
  • 2750 ± 50 KTemperature of grinding milk white light bulb
  • 26 piecesLight hole( Φ14)
  • Φ32 mmColor comparing tube

Wax Oil Content Tester LWCT-A22

  • AC 220 V ± 10 %, 50 HzPower supply
  • RT ~ 90 ℃ ± 5 ℃Temperature controlling range in water bath
  • (-35) ℃ ± 1 ℃Cooling bath temperature
  • 35 ℃ ± 1 ℃Evaporation temperature

Water Content Tester LWT-A10

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 WHeating Mantle Cap Power
  • 1 at a timeSample Determination

Water Content Tester LWT-A11

  • ≤ 35°CAmbient Temperature Range
  • ≤ 85%Relative Humidity
  • 1000 W × 2Heating Mantle Cap Power
  • 2 at a timeSample Determination
Coulometric Karl Fischer Titrator LWT-A30
  • 10°C to 35°CAmbient Temperature
  • 0 to 100 mgMeasurement Range
  • 0.1 µgResolution
  • 40 µg /sMax. Electrolysis Speed
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10
  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 1 s to 9 min 59 sTiming range
  • Room temperature to 99.9 °CTemperature controlling range

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11

  • Room temperature to 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Room temperature to 99.9 °CTemperature controlling range
  • ± 1 °CTemperature controlling accuracy

Kinematics Viscometer LKV-A13

  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a groupCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A11
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor
Kinematics Viscometer LKV-A12
  • (-10) °C ~ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • 11 piecesCapillary viscometer
  • 6 W, 1200 rpmStirring motor

Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11

  • Not less than 150 L / hAir flow rate
  • 99 min 59 s (100 min)Max. Preset time
  • Φ22 mmChamber diameter of oven
  • 1400 W × 2Heating power of oven

X-ray Fluorescence Sulfur in Oil Analyzer LST-A10

  • 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)Sample quantity
  • 60, 120, 240, 300, and 600 s at randomMeasurement time
  • 7 ppm to 5 %Measurement range
  • < 0.029 (S + 0.6)Repeatability
Constant Temperature Needle Penetration Tester LTNP-A10
  • 0 to 700 taper degree (digital display table 0-70 mm)Measuring range
  • Timing error is less than ±0.1 sTiming device
  • 0.01 mm Resolution
  • ±1 cone insertion degreeNeedle insertion accuracy