Water Soluble Acid and Alkali Tester LAAT-A10

Labtron LAAT-A10 is deliberately fabricated to have high accuracy and easy operation mode. It is constructed as per ASTM-D664 “Test Methods for Water Soluble Acid and Alkali of Petroleum Products”.

  • Graduated flask 100 ml,50 ml
    Conical flask 100ml
    Separatory funnel 250ml
    Volumetric analysis
    Automatic acid titration
    Automatic potential control
    Measurement range
    Potential measurement range
    Burette volume
    Minimum titration volume
    Burette precision
    Precision
    Ambient temperature (-10 )°C to 35 °C
    Relative humidity ≤ 85 %
    Temperature compensation
    Preset adjustment range of end point
    Preset controlling range for titration
    Precision of titration tube
    Test tube Φ18 mm x 100 mm
    Acidometer Full scale 0 ~ 14.00 pH
    Acidometer Accuracy ± 0.01 pH
    Heating power 100 W ~ 1000 W
    Total power consumption Not more than 1200 W
    Power supply AC 220 V ± 10 %, 50 Hz
    Dimension 570 x 540 x 260 mm
    Net weight
    • Heating power can be adjusted continuously
    • Accurate result
    • Easy to control and operate
    • Simple design
  • It is used to determine water soluble acid and alkali in the liquid petroleum products, additive, lubricating grease, wax and waxy products.

Acid Number Tester LAAT-A12

  • ≥0.05 mg KOH/gMeasurement range
  • 0 to 1800.0 mVPotential measurement range
  • 10 mLBurette volume
  • 0.001 mlMinimum titration volume

Acid Number and Acidity Tester LAAT-A11

  • ≤ 35 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • Scale division is 0.02 mlPrecision of titration tube
  • ≤ 1200 WTotal power consumption

Base Number Tester LAAT-A13

  • Titration condensation: 0.1 N;
    Controlling accuracy: ≤ ± 0.02 ml
    Volumetric analysis
  • Titration condensation: 0.1 N;
    Controlling accuracy: ≤ ± 0.1 pH
    Automatic acid titration
  • Titration condensation: 0.1 N;
    Controlling accuracy: ≤ 10 mV
    Automatic potential control
  • 0 ~ 35 ℃Ambient temperature

Benzene Distillation Tester (Low Temperature) LDT-A11

  • -10°C to 35°CAmbient temperature
  • ≤ 85 %Relative humidity
  • Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°CThermometer
  • 0.1 ℃Scale division

Distillation Tester Dual Units LDT-A15

  • 100 mlGraduated flasks
  • 1mlScale division of graduated flask
  • 125 mlDistillation flask
  • ≤ 35 °CAmbient temperature
Automatic Distillation Apparatus LADA-A10
  • 2 kWHeating power
  • 0.5 kWCooling power
  • 0 to 400℃Steam temperature
  • 0 to 500℃Oven temperature
Automatic Lubricating Oils Oxidation Stability Tester LOST-D10
  • 2Samples
  • 30 LOil bath cubage
  • 30 °Angle between bomb and water surface
  • 100 ± 5 RPMSpeed of rotary assembly

Transformer Oil Oxidation Stability Tester LOST-D11

  • 6Samples
  • Automatic digital temperatureTemperature controlling mode
  • Room temperature ~ 160 °CTemperature controlling range
  • ± 0.2 °CTemperature controlling accuracy

Distillate Fuel Oil Oxidation Stability Tester LOST-D12

  • 8Samples
  • 100 ℃Temperature
  • 0.1 ℃Temperature controlling accuracy
  • 3 ± 0.3 L / H oxygenFlow meter
Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12
  • (-10)℃ ~ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 31.0 ~ 32.0 mmSample cup Inner diameter
  • 1.0 ~ 1.5 mmSample cup Wall thickness
Solidifying Point Tester LLTT-A13
  • ± 0.5 ℃Temperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • Two holes in one trough, and same temperatureCold trough
  • ≤ 30 ℃Ambient temperature

Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15

  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity

Automatic Softening Point Tester LSPT-A10

  • 32 ℃ to 160 ℃Measurement range
  • 35 °CAmbient temperature
  • 0.01 ℃Temperature resolution
  • 1000 mLBeaker volume
Mercaptan Sulfur Tester LMST-A10
  • (0 to ±1999.5) MvPotential measuring range
  • 0.1 % ±0.5 mVIntrinsic error
  • Ri ≥1 × 1012 ΩInput impedance
  • 10 mLBurette capacity