Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15

Labtron LLTT- A15 is manufactured with two cold trough with same temperature. The instrument is designed and made as per ASTM D2386 “Test Methods for Solidifying Point of Petroleum Products”, and ASTM D6371 “Test Methods for Cold Filter Plugging Point of Distillate Fuel

  • Measurement range
    Temperature controlling accuracy
    Refrigeration system New-type refrigeration compressor
    Bath stirrer
    Sample stirrer
    Cold trough
    Controlling temperature of cold trough Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
    Constant temperature bath Cubage
    Constant temperature bath Types
    Temperature Range
    Temperature sensor
    Stirring motor Power
    Stirring motor Speed
    Ambient temperature ≤ 30 ℃
    Relative humidity ≤ 85 %
    Refrigeration speed
    Repeatability for solidifying point
    Repeatability for pour point
    Reproducibility
    Pressure of cooling water
    The lowest temperature
    Sample cup Inner diameter
    Sample cup Wall thickness
    Sample cup Height
    Pumping pressure
    Dimensions
    Inner Dimensions 560 x 380 x 250 mm
    Outer Dimensions 920 x 670 x 510 mm
    Total power consumption ≤ 1500 W
    Heating power
    Power supply AC 220 V ± 10 %, 50 Hz
    • Cold filter plugging point is provided
    • No need to use cooling liquid in the chambers
    • Composed of two chambers having same temperature
    • Both solidifying point test and cold filter plugging point test provided
  • It can be widely used in petroleum (solidifying point and cold filter plugging point), chemical industries, research and development laboratories.

Solidifying Point Tester LLTT-A20

  • ± 0.5 °CTemperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • One trough with two baths, temperatures in two baths are equalCold trough
  • Room temperature ~ (-70) °CControlling temperature of cold trough

Solidifying Point Tester (Solidifying Point and Cold Filter Plugging Point) LLTT-A21

  • New-type refrigeration compressorRefrigeration system
  • One trough with two baths, temperatures in two baths are equalCold trough
  • Room temperature ~ (-70) °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature

Freezing Point Tester LLTT-A11

  • -54°C to 2°CFreezing point range
  • -70° to 20°CCold bath measurement temperature range
  • ±0.5°CTemperature controlling accuracy
  • ElectricBath liquids stirring
Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12
  • (-10)℃ ~ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 31.0 ~ 32.0 mmSample cup Inner diameter
  • 1.0 ~ 1.5 mmSample cup Wall thickness
Multifunctional Low Temperature Tester LLTT-A16
  • New-type refrigeration compressorRefrigeration system
  • Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °CControlling temperature of cold trough
  • ≤ 30 ℃Ambient temperature
  • ≤ 85 %Relative humidity

Solidifying Point Constant Temperature Water Bath LLTT-A10

  • 20 LCapacity
  • Ambient +5°C to 100°CTemperature range
  • ± 0.1℃Precision
  • 1200 r/minStirring range

Pour and Cloud Point Tester LLTT-A14

  • 2 chambersChamber quantity
  • Ambient to -51 ℃Chamber 01 temperature control
  • Ambient to -65 ℃Chamber 02 temperature control
  • ±1°CTemperature precision

Solidifying Point Tester ('-20°C +80°C') LLTT-A22

  • ± 0.5 °CTemperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • One trough with two baths, temperatures in two baths are equalCold trough
  • Room temperature ~ (-70) °CControlling temperature of cold trough
Automatic Pour Point Tester LLTT-A23
  • ≤ 30 ℃Ambient temperature
  • > 40 °C / 10 minRefrigeration speed
  • ≤ 2 °CRepeatability for solidifying point
  • ≤ 3 °CRepeatability for pour point
Solidifying Point Tester LLTT-A13
  • ± 0.5 ℃Temperature controlling accuracy
  • New-type refrigeration compressorRefrigeration system
  • Two holes in one trough, and same temperatureCold trough
  • ≤ 30 ℃Ambient temperature

Penetrometer LMPT-A12

  • {"Measurement range":"0 to 600 penetration scale","Timing controller":"5 sec or 60 sec","Time accuracy":"\u00b1 0.1 seconds","Resolution":"0.1 penetration","Penetration accuracy":"\u00b1 1 penetration","Weight of standard needle":"2.5 \u00b1 0.05 g","Dimensions (W \u00d7 L \u00d7 H)":"700 \u00d7 400 \u00d7 750 mm","Weight":"30 kg"}Penetrometer
  • {"Bath volume":"3.5 L","Temperature range":"5 \u00b0C to 60 \u00b0C","Temperature accuracy":"\u00b1 0.1 \u00b0C","Circulatory water quantity":"3 L\/minute","Pump Lift":"2 m","Power consumption":"1200 W","Power supply":"AC 220V \u00b1 10 %, 50 Hz","Dimensions (W \u00d7 L \u00d7 H)":"600 \u00d7 400 \u00d7 650 mm","Weight":"40 kg"}Circulatory Water Bath

Penetrometer LMPT-A11

  • 0 to 600 penetration scaleMeasurement range
  • 5 sec or 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution
Penetrometer LMPT-A10
  • 0 to 600 penetration scaleMeasurement range
  • 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 secTiming controller
  • ± 0.1 secondsTime accuracy
  • 0.01 mmResolution
Wax Oil Content Tester LWCT-A22
  • AC 220 V ± 10 %, 50 HzPower supply
  • RT ~ 90 ℃ ± 5 ℃Temperature controlling range in water bath
  • (-35) ℃ ± 1 ℃Cooling bath temperature
  • 35 ℃ ± 1 ℃Evaporation temperature

Mechanical Impurity Tester (Weight Method) LMIT-A21

  • 390 x 260 x 590 mmDimension
  • ≤ 1200 WTotal power consumption
  • AC 220 V ± 10 %, 50 HzPower supply
  • 1000 WHeating power of water bath

Insulating Oil Breakdown Voltage Tester LIBT-A23

  • AC 220 V ± 5 % , 50HzPower supply
  • 0 ~ 75 kVMeasurement range
  • 3 kV ± 10 % / sVoltage rising rate
  • 2.5 mmDistance between electrodes
Carbon Residue Tester (CONRADSON METHODS) LRCT-B10
  • 30 mlPorcelain crucible
  • 75 mlInner iron crucible
  • 190 mlOuter iron crucible
  • Mig BurnerBurner
Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11
  • Four holes with a furnaceBath type
  • Electric resistance furnaceHeating type
  • 0 ~ 520 °CTemperature controlling range
  • ± 5 °CTemperature controlling accuracy

Carbon Residue Tester (Ramsbottom) LRCT-B20

  • Metal furnaceCoking furnace
  • Electric heatingHeating mode
  • 5 unitsTest unit
  • Ambient to 550°CTemperature range

Dropping Point Tester (Air bath) LDPT-A11

  • ≤ 35 ℃Ambient temperature
  • ≤ 85 %Relative humidity
  • 250 W × 2Heating power of electric furnace
  • ≤ 700 WTotal power consumption
Dropping Point Tester (Oil Bath) LDPT-A10
  • 600 mlBeaker quantity
  • (-10) °C ~ 40 °CAmbient temperature
  • ≤ 85 %Relative humidity
  • (-5) °C ~ 300 °CThermometer Measurement range
Aniline Point Tester LAPT-A10
  • Room temperature ~ 150°CMeasurement range
  • 0 ~ 1200 r / minStirring speed
  • 25 WHeating power
  • 360 × 250 × 545 mmInterior Dimension

Aniline Point Tester LAPT-A11

  • ≤ 0.5 ℃Temperature controlling accuracy
  • Room temperature ~ 200 ℃Temperature controlling range
  • 5 VPower supply for illumination
  • 2 kWPower of motor